Accuracy of thoracic vertebral body screw placement using standard fluoroscopy, fluoroscopic image guidance, and computed tomographic image guidance - A cadaver study

被引:163
作者
Mirza, SK
Wiggins, GC
Kuntz, C
York, JE
Bellabarba, C
Knonodi, MA
Chapman, JR
Shaffrey, CI
机构
[1] Univ Washington, Harborview Med Ctr, Dept Orthoped & Sports Med, Seattle, WA 98195 USA
[2] Univ Washington, Dept Neurol Surg, Seattle, WA 98195 USA
[3] Univ Cincinnati, Dept Neurol Surg, Cincinnati, OH USA
[4] Loyola Univ, Dept Neurol Surg, Maywood, IL 60153 USA
关键词
computed tomography; FluoroNav; fluoroscopy; image-guided surgery; radiation exposure; spinal fixation; spinal instrumentation; StealthStation; thoracic pedicle screws; thoracic spine fixation;
D O I
10.1097/00007632-200302150-00018
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Study Design. A surgical simulation study in human cadaver spine specimens was conducted to evaluate the accuracy of thoracic vertebral body screw placement using four different intraoperative imaging techniques. Objective. To compare standard fluoroscopy, fluoroscopy-based image guidance with two different referencing methods, and computed tomography-based image guidance by the measuring the time required for screw placement, the radiation exposure to specimen and surgeon, and the accuracy of screw position in the thoracic spine. Summary of Background Data. Image guidance provides additional anatomic information to the surgeon and may improve safety of technically difficult surgical procedures. The placement of screws in the thoracic spine is a technically demanding procedure in which inaccurate screw positioning places the spinal cord, nerve roots, and paraspinal structures such as the aorta and pleural space at risk for injury. Image-guided surgery may improve the accuracy of thoracic screw placement. Methods. Using four different intraoperative imaging methods, two experienced surgeons placed 337 vertebral body screws through the pedicles of thoracic vertebrate in 20 human cadaver thoracic spine specimens. The specimens than were examined with radiographs, computed tomography, and anatomic dissection to determine screw position. Measurements included procedure, setup and screw insertion time, radiation exposure to the specimen, the surgeon's hand, the surgeon's body, frequency, directional, and magnitude of screw perforation through the cortical margins of thoracic vertebrate. Results. As compared with surgery using standard fluoroscopy, fluoroscopy-based image guidance that uses multiple reference marks and computed tomography-based image guidance improves the accuracy of thoracic vertebral body screws placement and the specimen radiation exposure. Exposure to radiation is minimal at the surgeon's hand level and dependent on surgical technique at the surgeon's hand level. Screw perforation occurs most frequently in the lateral direction. Conclusions. Fluoroscopy-based image guidance that uses only a single reference marker for the entire thoracic spine is highly inaccurate and unsafe. Systems with registration based on the instrumented vertebrate provide more accurate placement of thoracic vertebral body screws than standard fluoroscopy, but expose the patient to more radiation and require more time for screw insertion.
引用
收藏
页码:402 / 413
页数:12
相关论文
共 44 条
  • [1] Comparative results between conventional and computer-assisted pedicle screw installation in the thoracic, lumbar, and sacral spine
    Amiot, LP
    Lang, K
    Putzier, M
    Zippel, H
    Labelle, H
    [J]. SPINE, 2000, 25 (05) : 606 - 614
  • [2] [Anonymous], 2006, Beautiful evidence
  • [3] Transpedicular screw placement -: Image-guided versus lateral-view fluoroscopy:: In vitro simulation
    Assaker, R
    Reyns, N
    Vinchon, M
    Demondion, X
    Louis, E
    [J]. SPINE, 2001, 26 (19) : 2160 - 2164
  • [4] BANTA CJ, 1989, ORTHOPEDICS, V12, P939
  • [5] In vivo accuracy of thoracic pedicle screws
    Belmont, PJ
    Klemme, WR
    Dhawan, A
    Polly, DW
    [J]. SPINE, 2001, 26 (21) : 2340 - 2346
  • [6] A COMPARISON OF FLUOROSCOPY AND COMPUTED TOMOGRAPHY-DERIVED VOLUMETRIC MULTIPLE EXPOSURE TRANSMISSION HOLOGRAPHY FOR THE GUIDANCE OF LUMBAR PEDICLE SCREW INSERTION
    BENZEL, EC
    RUPP, FW
    MCCORMACK, BM
    BALDWIN, NG
    ANSON, JA
    ADAMS, MS
    [J]. NEUROSURGERY, 1995, 37 (04) : 711 - 716
  • [7] In vitro simulation - Early results of stereotaxy for pedicle screw placement
    Carl, AL
    Khanuja, HS
    Sachs, BL
    Gatto, CA
    vomLehn, J
    Vosburgh, K
    Schenck, J
    Lorensen, W
    Rohling, K
    Disler, D
    [J]. SPINE, 1997, 22 (10) : 1160 - 1164
  • [8] Computer-assisted fluoroscopic targeting system for pedicle screw insertion
    Choi, WW
    Green, BA
    Levi, ADO
    [J]. NEUROSURGERY, 2000, 47 (04) : 872 - 878
  • [9] Pedicle instrumentation in the thoracic spine - A morphometric and cadaveric study for placement of screws
    Cinotti, G
    Gumina, S
    Ripani, M
    Postacchini, F
    [J]. SPINE, 1999, 24 (02) : 114 - 119
  • [10] Projection of the thoracic pedicle and its morphometric analysis
    Ebraheim, NA
    Xu, RM
    Ahmad, M
    Yeasting, RA
    [J]. SPINE, 1997, 22 (03) : 233 - 238