Research activities of DC Superconducting Power Transmission Line in Chubu University

被引:52
|
作者
Yamaguchi, Satarou [1 ,5 ]
Hamabe, Makoto [1 ,5 ]
Yamamoto, Isamu [1 ,5 ]
Famakinwa, Tosin [1 ,5 ]
Sasaki, Atsushi [1 ,5 ]
Iiyoshi, Atsuo [1 ,5 ]
Schultz, Joel [2 ]
Minervini, Joe [2 ]
Hoshino, Tsutomu [3 ]
Ishiguro, Yasuhide [4 ]
Kawamura, Kuniaki
机构
[1] Chubu Univ, Dept Elect Engn, Kasugai, Aichi 4878501, Japan
[2] MIT, Plasma Sci & Fusion Ctr, 77 Massachusetts Ave, Cambridge, MA 02139 USA
[3] Meisei Univ Tokyo, Dept Elect Engn, Tokyo 1918506, Japan
[4] JFE Steel Corp, Tita 4758611, Japan
[5] Maekawa Mfg Corp, Tokyo 1358482, Japan
关键词
D O I
10.1088/1742-6596/97/1/012290
中图分类号
O59 [应用物理学];
学科分类号
摘要
A experiment of a DC Superconducting power transmission line using HTS conductor was started in Chubu University, Japan in autumn 2006. The first cooling down began in October 2006. The coolant is liquid nitrogen, and the cooling system used a cryogenic cooler and cold pump. The operation temperature is the range of 72 K -80 K. The power cable has a total length of 20 m, and composed of thirty-nine Bi-2223 HTS tape conductors with critical current approximately100 A. The power cable achieved a 2.2 kA. The insulation voltage of the cable is 20 kV. In order to reduce the heat leakage and to avoid the current imbalance in the HTS tapes, we installed the Pelteir Current Lead (PCL) for each of the nineteen HTS tapes of the cable, with remaining twenty HTS tapes connected individually by the usual copper leads (CCL). Depending on the visual observation, and the measurement of temperatures of the current leads, the heat leakage of the PCL is lower than that of CCL. We installed a current transformer for each individual HTS tape conductor circuit, and measured the current of each HTS tape conductor. We measured the critical current of each HTS tape after the cable was installed into the cryostat, and degradation was not observed. Since the variation of the current in each tape is less than 10%, we eliminated the problem of current imbalance. Computational Fluid Dynamics is used to estimate the pressure drop, showing that the straight-tube cryostat has the advantage against the bellows-and corrugated-tube cryostats to reduce the pressure drop of the circulation of coolant. We proposed further to use the siphon for circulating the coolant in order to reduce the circulation losses and costs. We proposed that the voltage of the system be kept below 30 kV in order to use low cost power inverters. This choice can increase the storage energy of the power transmission line itself if we do not use a co-axial cable system because of it allows use of large current. And the magnetic energy of power grid is estimated to 4.5MJ/km for +/- 30 kA.
引用
收藏
页数:7
相关论文
共 50 条
  • [1] Recent Progress of Experiment on DC Superconducting Power Transmission Line in Chubu University
    Hamabe, Makoto
    Fujii, Tomohiro
    Yamamoto, Isamu
    Sasaki, Atsushi
    Nasu, Yuji
    Yamaguchi, SatarouYama
    Ninomiya, Akira
    Hoshino, Tsutomu
    Ishiguro, Yasuhide
    Kawamura, Kuniaki
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2009, 19 (03) : 1778 - 1781
  • [2] Cooling of the 200 m superconducting DC power transmission system at Chubu University
    Watanabe, Hirofumi
    Sun, Jian
    Ivanov, Yury
    Hamabe, Makoto
    Kawahara, Toshio
    Yamaguchi, Satarou
    ADVANCES IN SUPERCONDUCTIVITY XXIV, 2012, 27 : 376 - 379
  • [3] Experiment of the 200-meter superconducting DC transmission power cable in Chubu University
    Yamaguchi, Satarou
    Ivanov, Yury
    Sun, Jian
    Watanabe, Hirofumi
    Hamabe, Makoto
    Kawahara, Toshio
    Iiyoshi, Atsuo
    Sugino, Makoto
    Yamada, Hideki
    SUPERCONDUCTIVITY CENTENNIAL CONFERENCE 2011, 2012, 36 : 1131 - 1136
  • [4] Heat leak measurement of the 200 m superconducting DC power transmission system at Chubu University
    Center of Applied Superconductivity and Sustainable Energy Research, Chubu University, Kasugai, Aichi
    487-8501, Japan
    Phys. Procedia, (1366-1371):
  • [5] Cooling test of the 200 m superconducting DC transmission power cable system at Chubu University
    Watanabe, H.
    Sugino, M.
    Sun, J.
    Ivanov, Y.
    Hamabe, M.
    Kawahara, T.
    Yamaguchi, S.
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2011, 471 (21-22): : 1304 - 1307
  • [6] Heat leak measurement of the 200 m superconducting DC power transmission system at Chubu University
    Watanabe, Hirofumi
    Ivanov, Yury
    Sun, Jian
    Hamabe, Makoto
    Kawahara, Toshio
    Yamaguchi, Satarou
    SUPERCONDUCTIVITY CENTENNIAL CONFERENCE 2011, 2012, 36 : 1366 - 1371
  • [7] Long term operation in 200 m class superconducting DC power transmission test facility in Chubu University
    Hamabe, M.
    Watanabe, H.
    Sun, J.
    Kawahara, T.
    Yamaguchi, S.
    11TH EUROPEAN CONFERENCE ON APPLIED SUPERCONDUCTIVITY (EUCAS2013), PTS 1-4, 2014, 507
  • [8] Cryogenic system for DC superconducting power transmission line
    Hamabe, Makoto
    Sasaki, Atusushi
    Famakinwa, Tosin S.
    Ninomiya, Akira
    Ishiguro, Yasuhide
    Yamaguchi, Satarou
    IEEE TRANSACTIONS ON APPLIED SUPERCONDUCTIVITY, 2007, 17 (02) : 1722 - 1725
  • [9] Experiment of 200-meter superconducting DC cable system in Chubu University
    Yamaguchi, S.
    Kawahara, T.
    Hamabe, M.
    Watanabe, H.
    Ivanov, Yu.
    Sun, J.
    Iiyoshi, A.
    PHYSICA C-SUPERCONDUCTIVITY AND ITS APPLICATIONS, 2011, 471 (21-22): : 1300 - 1303
  • [10] THE EXPERIMENTS OF 200-METER SUPERCONDUCTING DC POWER CABLE IN CHUBU UNIVERSITY AND THE ESTIMATION FOR LONGER CABLE COOLING
    Yamaguchi, Satarou
    Ivanov, Yury
    Sun, Jian
    Watanabe, Hirofumi
    Hamabe, Makoto
    Kawahara, Toshio
    Iiyoshi, Atsuo
    ADVANCES IN CRYOGENIC ENGINEERING, VOLS 57A AND 57B, 2012, 1434 : 1959 - 1965