Validated Stability-Indicating GC-MS Method for Characterization of Forced Degradation Products of Trans-Caffeic Acid and Trans-Ferulic Acid

被引:24
作者
Razborsek, Masa Islamcevic [1 ]
Ivanovic, Milena [1 ]
Kolar, Mitja [2 ]
机构
[1] Univ Maribor, Fac Chem & Chem Engn, Smetanova Ulica 17, SI-2000 Maribor, Slovenia
[2] Univ Ljubljana, Fac Chem & Chem Technol, Vecna Pot 113, SI-1000 Ljubljana, Slovenia
来源
MOLECULES | 2021年 / 26卷 / 09期
关键词
caffeic acid; ferulic acid; stability studies; GC-MS; forced degradation; PHENOLIC-COMPOUNDS; ANTIOXIDANT ACTIVITY; CIS; PROPOLIS; EXTRACTION; IDENTIFICATION; ANTIBACTERIAL; DERIVATIVES; ANTIFUNGAL; CAPACITY;
D O I
10.3390/molecules26092475
中图分类号
Q5 [生物化学]; Q7 [分子生物学];
学科分类号
071010 ; 081704 ;
摘要
When dealing with simple phenols such as caffeic acid (CA) and ferulic acid (FA), found in a variety of plants, it is very important to have control over the most important factors that accelerate their degradation reactions. This is the first report in which the stabilities of these two compounds have been systematically tested by exposure to various different factors. Forced degradation studies were performed on pure standards (trans-CA and trans-FA), dissolved in different solvents and exposed to different oxidative, photolytic and thermal stress conditions. Additionally, a rapid, sensitive, and selective stability-indicating gas chromatographic-mass spectrometric method was developed and validated for determination of trans-CA and trans-FA in the presence of their degradation products. Cis-CA and cis-FA were confirmed as the only degradation products in all the experiments performed. All the compounds were perfectly separated by gas chromatography (GC) and identified using mass spectrometry (MS), a method that additionally elucidated their structures. In general, more protic solvents, higher temperatures, UV radiation and longer storage times led to more significant degradation (isomerization) of both trans-isomers. The most progressive isomerization of both compounds (up to 43%) was observed when the polar solutions were exposed to daylight at room temperature for 1 month. The method was validated for linearity, precision as repeatability, limit of detection (LOD) and limit of quantitation (LOQ). The method was confirmed as linear over tested concentration ranges from 1-100 mg L-1 (r(2)s were above 0.999). The LOD and LOQ for trans-FA were 0.15 mg L-1 and 0.50 mg L-1, respectively. The LOD and LOQ for trans-CA were 0.23 mg L-1 and 0.77 mg L-1, respectively.
引用
收藏
页数:12
相关论文
共 12 条