Validation of a Low-Cost Electrocardiography (ECG) System for Psychophysiological Research

被引:6
作者
Wagner, Ruth Erna [1 ]
da Silva, Hugo Placido [2 ]
Gramann, Klaus [1 ]
机构
[1] TU Berlin, Chair Biol Psychol & Neuroergon, D-10623 Berlin, Germany
[2] IT Inst Telecomunicacoes, P-1049001 Lisbon, Portugal
关键词
BITalino; BrainAmp; ICC; intraclass correlation coefficient; Bland-Altman method; HEART-RATE-VARIABILITY; AGREEMENT; PERFORMANCE; EMOTION;
D O I
10.3390/s21134485
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
Background and Objective: The reliability of low-cost mobile systems for recording Electrocardiographic (ECG) data is mostly unknown, posing questions regarding the quality of the recorded data and the validity of the extracted physiological parameters. The present study compared the BITalino toolkit with an established medical-grade ECG system (BrainAmp-ExG). Methods: Participants underwent simultaneous ECG recordings with the two instruments while watching pleasant and unpleasant pictures of the "International Affective Picture System" (IAPS). Common ECG parameters were extracted and compared between the two systems. The Intraclass Correlation Coefficients (ICCs) and the Bland-Altman Limits of Agreement (LoA) method served as criteria for measurement agreement. Results: All but one parameter showed an excellent agreement (>80%) between both devices in the ICC analysis. No criteria for Bland-Altman LoA and bias were found in the literature regarding ECG parameters. Conclusion: The results of the ICC and Bland-Altman methods demonstrate that the BITalino system can be considered as an equivalent recording device for stationary ECG recordings in psychophysiological experiments.
引用
收藏
页数:17
相关论文
共 44 条
  • [1] MEASUREMENT IN MEDICINE - THE ANALYSIS OF METHOD COMPARISON STUDIES
    ALTMAN, DG
    BLAND, JM
    [J]. JOURNAL OF THE ROYAL STATISTICAL SOCIETY SERIES D-THE STATISTICIAN, 1983, 32 (03) : 307 - 317
  • [2] Anttonen Jenni, 2005, P SIGCHI C HUM FACT, P491, DOI [DOI 10.1145/1054972.1055040, 10.1145/1054972.1055040]
  • [3] Effect of Missing Inter-Beat Interval Data on Heart Rate Variability Analysis Using Wrist-Worn Wearables
    Baek, Hyun Jae
    Shin, JaeWook
    [J]. JOURNAL OF MEDICAL SYSTEMS, 2017, 41 (10)
  • [4] Agreement between methods of measurement with multiple observations per individual
    Bland, J. Martin
    Altman, Douglas G.
    [J]. JOURNAL OF BIOPHARMACEUTICAL STATISTICS, 2007, 17 (04) : 571 - 582
  • [5] Bland JM, 1999, STAT METHODS MED RES, V8, P135, DOI 10.1177/096228029900800204
  • [6] STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
    BLAND, JM
    ALTMAN, DG
    [J]. LANCET, 1986, 1 (8476) : 307 - 310
  • [7] BLAND JM, 1992, CURRENT CONTENT 1005, V40, P8
  • [8] A Review, Current Challenges, and Future Possibilities on Emotion Recognition Using Machine Learning and Physiological Signals
    Bota, Patricia J.
    Wang, Chen
    Fred, Ana L. N.
    da Silva, Hugo Placido
    [J]. IEEE ACCESS, 2019, 7 : 140990 - 141020
  • [9] Bradley MM, 2000, PSYCHOPHYSIOLOGY, V37, P204, DOI 10.1111/1469-8986.3720204
  • [10] STARTLE REFLEX MODIFICATION - EMOTION OR ATTENTION
    BRADLEY, MM
    CUTHBERT, BN
    LANG, PJ
    [J]. PSYCHOPHYSIOLOGY, 1990, 27 (05) : 513 - 522