Magnetic resonance imaging of single rice kernels during cooking

被引:44
作者
Mohoric, A
Vergeldt, F
Gerkema, E
de Jager, A
van Duynhoven, J
van Dalen, G
Van As, H
机构
[1] Univ Wageningen, Lab Biophys, NL-6703 HA Wageningen, Netherlands
[2] Unilever Res Labs Vlaardingen, NL-3130 AC Vlaardingen, Netherlands
[3] Univ Wageningen, Wageningen NMR Ctr, NL-6703 HA Wageningen, Netherlands
关键词
hydration; gelatinization; rice; cooking; RARE; magnetic resonance imaging;
D O I
10.1016/j.jmr.2004.08.013
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
The RARE imaging method was used to monitor the cooking of single rice kernels in real time and with high spatial resolution in three dimensions. The imaging sequence is optimized for rapid acquisition of signals with short relaxation times using centered out RARE. Short scan time and high spatial resolution are critical factors in the investigation of the cooking behavior of rice kernels since time and spatial averaging may lead to erroneous results. The results are confirming the general pattern of moisture ingress that has been suspected from previous (more limited) studies. Water uptake as determined by analysis of the MRI time series recorded during cooking compares well with gravimetric studies. This allows using these real-time MRI data for developing and validating models that describe the effect of kernel microstructure on its cooking behavior. (C) 2004 Elsevier Inc. All rights reserved.
引用
收藏
页码:157 / 162
页数:6
相关论文
共 17 条
  • [1] Modeling of moisture profiles in paddy rice during drying mapped with magnetic resonance imaging
    Frías, JM
    Foucat, L
    Bimbenet, JJ
    Bonazzi, C
    [J]. CHEMICAL ENGINEERING JOURNAL, 2002, 86 (1-2) : 173 - 178
  • [2] MRI observation and mathematical model simulation of water migration in wheat flour dough during boiling
    Fukuoka, M
    Mihori, T
    Watanabe, H
    [J]. JOURNAL OF FOOD SCIENCE, 2000, 65 (08) : 1343 - 1348
  • [3] The rate of starch gelatinization as observed by PFG-NMR measurement of water diffusivity in rice starch/water mixtures
    Gomi, Y
    Fukuoka, M
    Mihori, T
    Watanabe, H
    [J]. JOURNAL OF FOOD ENGINEERING, 1998, 36 (04) : 359 - 369
  • [4] HE G, 1987, J NUTR SCI VITAMINOL, V33, P263
  • [5] RARE IMAGING - A FAST IMAGING METHOD FOR CLINICAL MR
    HENNIG, J
    NAUERTH, A
    FRIEDBURG, H
    [J]. MAGNETIC RESONANCE IN MEDICINE, 1986, 3 (06) : 823 - 833
  • [6] Hills B., 1998, MAGNETIC RESONANCE I
  • [7] Internal hollows in cooked rice grains (Oryza sativa cv. Koshihikari) observed by NMR micro imaging
    Horigane, AK
    Toyoshima, H
    Hemmi, H
    Engelaar, WMHG
    Okubo, A
    Nagata, T
    [J]. JOURNAL OF FOOD SCIENCE, 1999, 64 (01) : 1 - 5
  • [8] NAKAZAWA F, 1978, KASEIGAKU ZASSHI, V29, P140
  • [9] Microscopic displacement imaging with pulsed field gradient turbo spin-echo NMR
    Scheenen, TWJ
    van Dusschoten, D
    de Jager, PA
    Van As, H
    [J]. JOURNAL OF MAGNETIC RESONANCE, 2000, 142 (02) : 207 - 215
  • [10] NMR imaging of the wheat grain cooking process
    Stapley, AGF
    Hyde, TM
    Gladden, LF
    Fryer, PJ
    [J]. INTERNATIONAL JOURNAL OF FOOD SCIENCE AND TECHNOLOGY, 1997, 32 (05) : 355 - 375