Rapid bonding of Pyrex glass microchips

被引:22
作者
Akiyama, Yoshitake
Morishima, Keisuke
Kogi, Atsuna
Kikutani, Yoshikuni
Tokeshi, Manabu
Kitamori, Takehiko
机构
[1] Univ Tokyo, Sch Engn, Dept Appl Chem, Bunkyo Ku, Tokyo 1138656, Japan
[2] Inst Microchem Technol, Takatsu Ku, Kawasaki, Kanagawa, Japan
[3] Tokyo Univ Agr & Technol, Dept Mech Syst Engn, Koganei, Tokyo, Japan
[4] KAST, Micro Chem Grp, Opt Sci Lab, Takatsu Ku, Kawasaki, Kanagawa, Japan
[5] Nagoya Univ, Grad Sch Engn, Dept Appl Chem, Nagoya, Aichi, Japan
关键词
microchip; microelectrocle; Pyrex glass; rapid bonding;
D O I
10.1002/elps.200600437
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
A newly developed vacuum hot press system has been specially designed for the thermal bonding of glass substrates in the fabrication process of Pyrex glass microchemical chips. This system includes a vacuum chamber equipped with a high-pressure piston cylinder and carbon plate heaters. A temperature of up to 900 degrees C and a force of as much as 9800 N could be applied to the substrates in a vacuum atmosphere. The Pyrex substrates bonded with this system under different temperatures, pressures, and heating times were evaluated by tensile strength tests, by measurements of thickness, and by observations of the cross-sectional shapes of the microchannels. The optimal bonding conditions of the Pyrex glass substrates were 570 degrees C for 10 min under 4.7 N/mm(2) of applied pressure. Whereas more than 16 h is required for thermal bonding with a conventional furnace, the new system could complete the whole bonding processes within just 79 min, including heating and cooling periods. Such improvements should considerably enhance the production rate of Pyrex glass microchemical chips. Whereas flat and dust-free surfaces are required for conventional thermal bonding, especially without long and repeated heating periods, our hot press system could press a fine dust into glass substrates so that even the areas around the dust were bonded. Using this capability, we were able to successfully integrate Pt/Ti thin film electrodes into a Pyrex glass microchip.
引用
收藏
页码:994 / 1001
页数:8
相关论文
共 45 条
  • [1] Planar quartz chips with submicron channels for two-dimensional capillary electrophoresis applications
    Becker, H
    Lowack, K
    Manz, A
    [J]. JOURNAL OF MICROMECHANICS AND MICROENGINEERING, 1998, 8 (01) : 24 - 28
  • [2] Room temperature bonding of micromachined glass devices for capillary electrophoresis
    Chiem, N
    Lockyear-Shultz, L
    Andersson, P
    Skinner, C
    Harrison, DJ
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2000, 63 (03) : 147 - 152
  • [3] Choi JW, 1997, P ANN INT IEEE EMBS, V19, P2264, DOI 10.1109/IEMBS.1997.758812
  • [4] Bonding characteristics of 3C-SiC wafers with hydrofluoric acid for high-temperature MEMS applications
    Chung, GS
    Maboudian, R
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2005, 119 (02) : 599 - 604
  • [5] Microdevices for manipulation and accumulation of micro- and nanoparticles by dielectrophoresis
    Dürr, M
    Kentsch, J
    Müller, T
    Schnelle, T
    Stelzle, M
    [J]. ELECTROPHORESIS, 2003, 24 (04) : 722 - 731
  • [6] Dielectrophoretic sorting of particles and cells in a microsystem
    Fiedler, S
    Shirley, SG
    Schnelle, T
    Fuhr, G
    [J]. ANALYTICAL CHEMISTRY, 1998, 70 (09) : 1909 - 1915
  • [7] Optical contact and van der Waals interactions: the role of the surface topography in determining the bonding strength of thick glass plates
    Greco, V
    Marchesini, F
    Molesini, G
    [J]. JOURNAL OF OPTICS A-PURE AND APPLIED OPTICS, 2001, 3 (01): : 85 - 88
  • [8] MICROMACHINING A MINIATURIZED CAPILLARY ELECTROPHORESIS-BASED CHEMICAL-ANALYSIS SYSTEM ON A CHIP
    HARRISON, DJ
    FLURI, K
    SEILER, K
    FAN, ZH
    EFFENHAUSER, CS
    MANZ, A
    [J]. SCIENCE, 1993, 261 (5123) : 895 - 897
  • [9] Integrated multilayer flow system on a microchip
    Hibara, A
    Tokeshi, M
    Uchiyama, K
    Hisamoto, H
    Kitamori, T
    [J]. ANALYTICAL SCIENCES, 2001, 17 (01) : 89 - 93
  • [10] Huang ZL, 2001, ELECTROPHORESIS, V22, P3924, DOI 10.1002/1522-2683(200110)22:18<3924::AID-ELPS3924>3.0.CO