A LC-MS/MS method to monitor the concentration of HYD-PEP06, a RGD-modified Endostar mimetic peptide in rat blood

被引:6
作者
Dong, Xiaona [1 ]
Zhang, Yiwei [1 ,2 ]
Meng, Zhiyun [1 ]
Zhu, Xiaoxia [1 ]
Gan, Hui [1 ]
Gu, Ruolan [1 ]
Wu, Zhuona [1 ]
Li, Jian [1 ]
Zheng, Ying [1 ]
Yang, Baofeng [3 ]
Dou, Guifang [1 ]
机构
[1] Beijing Inst Radiat Med, State Key Lab Drag Metab & Pharmacokinet, Dept Pharmaceut Sci, 27 Taiping Rd, Beijing 100850, Peoples R China
[2] Guangxi Med Univ, 22 Shuangyong Rd, Nanning 530000, Peoples R China
[3] Harbin Med Univ, 157 Baojian Rd, Harbin, Heilongjiang, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2018年 / 1092卷
关键词
Peptide; Carryover; Stability; LC-MS/MS; Anti-carcinoma; TANDEM MASS-SPECTROMETRY; PERFORMANCE LIQUID-CHROMATOGRAPHY; RECOMBINANT HUMAN ENDOSTATIN; CEREBROSPINAL-FLUID; PLASMA; ASSAY; QUANTIFICATION; CARRYOVER; VALIDATION; NEUROPEPTIDES;
D O I
10.1016/j.jchromb.2018.05.042
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
HYD-PEP06 is a novel RGD-modified Endostar mimetic peptide with 30 amino acids that is intended to suppress the formation of neoplasm vessels. This assay was developed and validated to monitor the level of the peptide HYD-PEP06 in rat blood, using liquid chromatography tandem mass spectrometry (LC-MS/MS). HYD-PEP10, another peptide similar to the analyte, was used as an internal standard (IS). A triple quadrupole mass spectrometry in Multiple Reaction Monitoring (MRM) mode and an electrospray interface (ESI) in the positive mode were used for MS analysis. The analysis was optimized with addition of 0.3% formic acid (FA) into the mobile phase as well as with a needle washing solution to overcome the carryover effect. In addition, the carryover was reduced by optimizing the mobile phase gradient Methanol was used as a diluent of working solutions to avoid any adsorption. Methanol:acetonitrile (1:1, v:v) containing 0.3% FA was employed to precipitate the blood samples. Unknown blood samples must be placed in ice bath immediately, and precipitating agents should be added within 30 min to ensure the stability of blood samples. The assay was established and validated. This method showed a good linear relationship for the HYD-PEP06 in the range of 10 ng.mL (-1) to 2000 ng-mL(-1), with R > 0.99. HYD-PEP06 was determined with accuracy values (RE%) of - 5.06%-8.54%, intra- and inter-day precisions (RSD%) of 3.13%-4.87% and 4.81%-9.42%. The method was successfully in monitoring the concentration of HYD-PEP06 in rat blood.
引用
收藏
页码:296 / 305
页数:10
相关论文
共 32 条
  • [21] Phase I pharmacokinetic and pharmacodynamic study of recombinant human endostatin in patients with advanced solid tumors
    Thomas, JP
    Arzoomanian, RZ
    Alberti, D
    Marnocha, R
    Lee, F
    Friedl, A
    Tutsch, K
    Dresen, A
    Geiger, P
    Pluda, J
    Fogler, W
    Schiller, JH
    Wilding, G
    [J]. JOURNAL OF CLINICAL ONCOLOGY, 2003, 21 (02) : 223 - 231
  • [22] Quantification of [Dmt1]DALDA in ovine plasma by on-line liquid chromatography/quadrupole time-of-flight mass spectrometry
    Wan, HB
    Desiderio, DM
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2003, 17 (06) : 538 - 546
  • [23] Williams JS, 2012, BIOANALYSIS, V4, P1025, DOI [10.4155/BIO.12.76, 10.4155/bio.12.76]
  • [24] Development and validation of a method for the determination of a therapeutic peptide with affinity for the human B1 receptor in human plasma using HPLC-MS/MS
    Wilson, S. F.
    Li, H.
    Rose, M. J.
    Xiao, J.
    Holder, J. R.
    James, C. A.
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2010, 878 (9-10): : 749 - 757
  • [25] Yang B. F., 2015, CN Patent, Patent No. 104530199
  • [26] Validation of a sensitive assay for thiocoraline in mouse plasma using liquid chromatography-tandem mass spectrometry
    Yin, JM
    Aviles, P
    Lee, W
    Ly, C
    Guillen, MJ
    Calvo, P
    Manzanares, I
    Faircloth, G
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2003, 794 (01): : 89 - 98
  • [27] A new approach for evaluating carryover and its influence on quantitation in high-performance liquid chromatography and tandem mass spectrometry assay
    Zeng, W
    Musson, DG
    Fisher, AL
    Wang, AQ
    [J]. RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2006, 20 (04) : 635 - 640
  • [28] High-Throughput Proteomics
    Zhang, Zhaorui
    Wu, Si
    Stenoien, David L.
    Pasa-Tolic, Ljiljana
    [J]. ANNUAL REVIEW OF ANALYTICAL CHEMISTRY, VOL 7, 2014, 7 : 427 - 454
  • [29] Endostatin derivative angiogenesis inhibitors
    Zheng Meng-Jie
    [J]. CHINESE MEDICAL JOURNAL, 2009, 122 (16) : 1947 - 1951
  • [30] Reducing Adsorption To Improve Recovery and in Vivo Detection of Neuropeptides by Microdialysis with LC-MS
    Zhou, Ying
    Wong, Jenny-Marie T.
    Mabrouk, Omar S.
    Kennedy, Robert T.
    [J]. ANALYTICAL CHEMISTRY, 2015, 87 (19) : 9802 - 9809