A LC-MS/MS method to monitor the concentration of HYD-PEP06, a RGD-modified Endostar mimetic peptide in rat blood

被引:6
作者
Dong, Xiaona [1 ]
Zhang, Yiwei [1 ,2 ]
Meng, Zhiyun [1 ]
Zhu, Xiaoxia [1 ]
Gan, Hui [1 ]
Gu, Ruolan [1 ]
Wu, Zhuona [1 ]
Li, Jian [1 ]
Zheng, Ying [1 ]
Yang, Baofeng [3 ]
Dou, Guifang [1 ]
机构
[1] Beijing Inst Radiat Med, State Key Lab Drag Metab & Pharmacokinet, Dept Pharmaceut Sci, 27 Taiping Rd, Beijing 100850, Peoples R China
[2] Guangxi Med Univ, 22 Shuangyong Rd, Nanning 530000, Peoples R China
[3] Harbin Med Univ, 157 Baojian Rd, Harbin, Heilongjiang, Peoples R China
来源
JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES | 2018年 / 1092卷
关键词
Peptide; Carryover; Stability; LC-MS/MS; Anti-carcinoma; TANDEM MASS-SPECTROMETRY; PERFORMANCE LIQUID-CHROMATOGRAPHY; RECOMBINANT HUMAN ENDOSTATIN; CEREBROSPINAL-FLUID; PLASMA; ASSAY; QUANTIFICATION; CARRYOVER; VALIDATION; NEUROPEPTIDES;
D O I
10.1016/j.jchromb.2018.05.042
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
HYD-PEP06 is a novel RGD-modified Endostar mimetic peptide with 30 amino acids that is intended to suppress the formation of neoplasm vessels. This assay was developed and validated to monitor the level of the peptide HYD-PEP06 in rat blood, using liquid chromatography tandem mass spectrometry (LC-MS/MS). HYD-PEP10, another peptide similar to the analyte, was used as an internal standard (IS). A triple quadrupole mass spectrometry in Multiple Reaction Monitoring (MRM) mode and an electrospray interface (ESI) in the positive mode were used for MS analysis. The analysis was optimized with addition of 0.3% formic acid (FA) into the mobile phase as well as with a needle washing solution to overcome the carryover effect. In addition, the carryover was reduced by optimizing the mobile phase gradient Methanol was used as a diluent of working solutions to avoid any adsorption. Methanol:acetonitrile (1:1, v:v) containing 0.3% FA was employed to precipitate the blood samples. Unknown blood samples must be placed in ice bath immediately, and precipitating agents should be added within 30 min to ensure the stability of blood samples. The assay was established and validated. This method showed a good linear relationship for the HYD-PEP06 in the range of 10 ng.mL (-1) to 2000 ng-mL(-1), with R > 0.99. HYD-PEP06 was determined with accuracy values (RE%) of - 5.06%-8.54%, intra- and inter-day precisions (RSD%) of 3.13%-4.87% and 4.81%-9.42%. The method was successfully in monitoring the concentration of HYD-PEP06 in rat blood.
引用
收藏
页码:296 / 305
页数:10
相关论文
共 32 条
  • [1] Quantitative assay for bradykinin in rat plasma by liquid chromatography coupled to tandem mass spectrometry
    Baralla, Elena
    Nieddu, Maria
    Boatto, Gianpiero
    Varoni, Maria Vittoria
    Palomba, Domenico
    Demontis, Maria Piera
    Pasciu, Valeria
    Anania, Vittorio
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2011, 54 (03) : 557 - 561
  • [2] Bioanalytical method development and validation for a large peptide HIV fusion inhibitor (Enfuvirtide, T-20) and its metabolite in human plasma using LC-MS/MS
    Chang, D
    Kolis, SJ
    Linderholm, KH
    Julian, TF
    Nachi, R
    Dzerk, AM
    Lin, PP
    Lee, JW
    Bansal, SK
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2005, 38 (03) : 487 - 496
  • [3] Ewles M, 2011, BIOANALYSIS, V3, P1379, DOI [10.4155/BIO.11.112, 10.4155/bio.11.112]
  • [4] Quantification of Gluten Exorphin A5 in cerebrospinal fluid by liquid chromatography-mass spectrometry
    Fanciulli, G
    Azara, E
    Wood, TD
    Dettorl, A
    Delitala, G
    Marchetti, M
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2006, 833 (02): : 204 - 209
  • [5] Liquid chromatography-mass spectrometry assay for quantification of Gluten Exorphin B5 in cerebrospinal fluid
    Fanciulli, Giuseppe
    Azara, Emanuela
    Wood, Troy D.
    Delitala, Giuseppe
    Marchetti, Mauro
    [J]. JOURNAL OF CHROMATOGRAPHY B-ANALYTICAL TECHNOLOGIES IN THE BIOMEDICAL AND LIFE SCIENCES, 2007, 852 (1-2): : 485 - 490
  • [6] LC/MS/MS plasma assay for the peptidomimetic VLA4 antagonist I and its major active metabolite II: for treatment of asthma by inhalation
    Fisher, AL
    DePuy, E
    Jayaraj, A
    Raab, C
    Braun, M
    Ellis-Hutchings, M
    Zhang, J
    Rogers, JD
    Musson, DG
    [J]. JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2002, 27 (1-2) : 57 - 71
  • [7] Antiangiogenesis in cancer therapy - endostatin and its mechanisms of action
    Folkman, J
    [J]. EXPERIMENTAL CELL RESEARCH, 2006, 312 (05) : 594 - 607
  • [8] Guidance for Industry, 2015, BIOAN METH VAL
  • [9] Bioanalytical determination of unstable endogenous small peptides: RFRP3 & its metabolites in rat, blood
    Haynes, Julian J.
    Jones, Hannah
    Gibson, Drew
    Clark, Graeme T.
    [J]. BIOANALYSIS, 2011, 3 (07) : 763 - 778
  • [10] Determination of carryover and contamination for mass spectrometry-based chromatographic assays
    Hughes, Nicola C.
    Wong, Ernest Y. K.
    Fan, Juan
    Bajaj, Navgeet
    [J]. AAPS JOURNAL, 2007, 9 (03) : E353 - E360