Elimination of matrix effect and simultaneous determination of multi-components in complex systems by matrix coefficient non-linearity multivariate calibration based on single point response signals

被引:13
作者
Zhang, Tai-Ming [1 ]
Yuan, Bin [1 ]
Liang, Yi-Zeng [1 ]
Cao, Juan [1 ]
Pan, Chun-Xiao [1 ]
Ying, Bin [1 ]
Lu, Di-Yi [1 ]
机构
[1] Cent S Univ, Coll Chem & Chem Engn, Changsha 410083, Peoples R China
关键词
D O I
10.2116/analsci.23.581
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
In order to deal with the matrix effect in the simultaneous determination of multi-components in a complex system, we have developed a novel method named matrix coefficient multivariate calibration method (MCMCM) for simultaneously determining n analytes in complex systems. The calibration models of n analytes, which are based on the experimental data of known samples, are first transformed into n linear equations, and then the equations are solved to obtain matrix calibration coefficients of the analytes in congeneric samples. In this way, the concentrations of n analytes in the unknown sample could be obtained easily and simultaneously by solving another n-variate linear equations with the help of the matrix calibration coefficients obtained-above. The method proposed in this work has been tested by voltammetry and atomic absorption spectrometry (AAS) with satisfactory results. On determining the elements such as Cu, Pb, Cd, Ni, Zn, Fe, Mn, Co, Ca, Mg, etc. in synthetic samples, the relative standard deviations (RSDs) of the results were 0.91-4.5%, and the recoveries were 95.8 - 105%. For actual samples, the RSDs and the recoveries were 1.5 - 6.9 and 92.0-110%, respectively.
引用
收藏
页码:581 / 587
页数:7
相关论文
共 15 条
[1]   Determination of elements in some lichens growing in Giresun and Ordu province (Turkey) using energy dispersive X-ray fluorescence spectrometry [J].
Aslan, A ;
Budak, G ;
Tirasoglu, E ;
Karabulut, A .
JOURNAL OF QUANTITATIVE SPECTROSCOPY & RADIATIVE TRANSFER, 2006, 97 (01) :10-19
[2]   Matrix removal for the ion chromatographic determination of some trace elements in milk [J].
Buldini, PL ;
Cavalli, S ;
Sharma, JL .
MICROCHEMICAL JOURNAL, 2002, 72 (03) :277-284
[3]   Analysis of environmental pollutants metabolized from pesticides using capillary electrophoresis with multiphoton-excited fluorescence detection [J].
Chen, Sheng ;
Xu, Youzhi ;
Bi, Yanhua ;
Du, Wei ;
Liu, Bi-Feng .
TALANTA, 2006, 70 (01) :63-67
[4]   Adsorptive square-wave voltammetry applied to study the reduction mechanism of Cu-sulfoxine and Cu-ferron complexes [J].
Garay, F ;
Solis, VM .
JOURNAL OF ELECTROANALYTICAL CHEMISTRY, 2003, 544 :1-11
[5]   Comparison of the volatile compounds of Atractylodes medicinal plants by headspace solid-phase microextraction-gas chromatography-mass spectrometry [J].
Guo, Fang-Qiu ;
Huang, Lan-Fang ;
Zhou, Shao-Yun ;
Zhang, Tai-Ming ;
Liang, Yi-Zeng .
ANALYTICA CHIMICA ACTA, 2006, 570 (01) :73-78
[6]   Identification and determination of nucleosides in Cordyceps sinensis and its substitutes by high performance liquid chromatography with mass spectrometric detection [J].
Guo, FQ ;
Li, A ;
Huang, LF ;
Liang, YZ ;
Chen, BM .
JOURNAL OF PHARMACEUTICAL AND BIOMEDICAL ANALYSIS, 2006, 40 (03) :623-630
[7]   Comparison of the volatile constituents of Artemisia capillaris from different locations by gas chromatography-mass spectrometry and projection method [J].
Guo, FQ ;
Liang, YZ ;
Xu, CJ ;
Huang, LF ;
Li, XN .
JOURNAL OF CHROMATOGRAPHY A, 2004, 1054 (1-2) :73-79
[8]   Multielemental fast analysis of vegetation samples by wavelength dispersive X-ray fluorescence spectrometry:: Possibilities and drawbacks [J].
Marguí, E ;
Hidalgo, M ;
Queralt, I .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (9-10) :1363-1372
[9]   Direct determination of Cu, Mn, Pb, and Zn in beer by thermospray flame furnace atomic absorption spectrometry [J].
Nascentes, CC ;
Kamogawa, MY ;
Fernandes, KG ;
Arruda, MAZ ;
Nogueira, ARA ;
Nóbrega, JA .
SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2005, 60 (05) :749-753