Performance investigation of salt gradient cylindrical solar pond integrated and nonintegrated with evacuated tube solar collectors

被引:5
作者
Atiz, Ayhan [1 ]
Bozkurt, Ismail [2 ]
Karakilcik, Mehmet [3 ]
机构
[1] Alanya Alaaddin Keykubat Univ, Dept Math & Sci Educ, Fac Educ, Antalya, Turkey
[2] Adiyaman Univ, Dept Mech Engn, Fac Engn, Adiyaman, Turkey
[3] Univ Cukurova, Fac Sci & Letters, Dept Phys, TR-01330 Adana, Turkey
关键词
energy; exergy; heat storage; solar collector; solar pond; HEAT EXTRACTION; ENERGY; EXERGY;
D O I
10.1002/er.4304
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
In this study, the energetic and exergetic efficiencies of a salt gradient cylindrical solar pond (SGCSP) that integrated and nonintegrated evacuated tube solar collectors (ETSCs) are investigated to improve daily heat preservation performance of the heat storage zone (HSZ). The integrated system is consisted of an SGCSP and four ETSCs. The SGCSP has a surface area of 2 m(2), a depth of 1.65 m, salty water layers at different densities, and HSZ in which the cylindrical serpentine type heat exchanger (CSHE) is located. Thus, the daily effects of the heat storage performance of both the ETSCs and the SGCSP in the winter season was determined experimentally. The analysis of the data regarding the efficiencies of the system is investigated separately by means of experimental studies where the SGCSP is integrated and nonintegrated with the ETSCs. The number of ETSCs integrated with SGCSP is increased to 1, 2, 3, and 4, respectively, and each of the five different experimental systems is performed separately. The temperature distributions of the integrated system are measured by a data acquisition system on 11 different points per hour. The efficiencies are calculated using the data obtained from these studies. Consequently, the energetic and exergetic efficiencies of the SGCSP are obtained without collectors as 10.4% and 4.3% and with one collector as 12.83% and 6.15%, with two collectors 14.88% and 8.25%, with three collectors 16% and 9.35%, and finally with four collectors 16.94% and 10.3%, respectively. Furthermore, the theoretical efficiencies are found to be consistent with the experimental results obtained by increasing the collector numbers.
引用
收藏
页码:6243 / 6255
页数:13
相关论文
共 50 条
  • [21] Analytical characteristic equation of N identical evacuated tubular collectors integrated single slope solar still
    Singh, D. B.
    Dwivedi, V. K.
    Tiwari, G. N.
    Kumar, Navneet
    DESALINATION AND WATER TREATMENT, 2017, 88 : 41 - 51
  • [22] Exergetic performance analysis of a salinity gradient solar pond
    Khalilian, Morteza
    SOLAR ENERGY, 2017, 157 : 895 - 904
  • [23] Performance analysis of a combined cooling, heat, electricity and hydrogen plant powered by evacuated tube solar collectors
    Khammal, Salim
    Khouya, Ahmed
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2025, 101 : 34 - 46
  • [24] Development of Dynamic Thermal Modeling for Evacuated U-Tube Solar Collectors
    Toker, Serpil Celik
    Kizilkan, Onder
    ARABIAN JOURNAL FOR SCIENCE AND ENGINEERING, 2024,
  • [25] Effect of heat extraction on the thermal efficiency of salt gradient solar pond
    Wu, Qi
    Wang, Hua
    Xie, Shukuan
    Zhang, Liugang
    Wang, Jie
    Dong, Zhanwei
    Zhao, Tao
    ENERGY EXPLORATION & EXPLOITATION, 2019, 37 (05) : 1502 - 1515
  • [26] Design of a solar-driven cogeneration system using flat plate collectors and evacuated tube collectors
    Bellos, Evangelos
    Tzivanidis, Christos
    INTERNATIONAL JOURNAL OF ENERGY RESEARCH, 2019, 43 (11) : 5841 - 5851
  • [27] Annual Performance Evaluation of Evacuated Tube Solar Air Collector With Phase Change Material
    Mehla, Neeraj
    Kumar, Manoj
    Yadav, Avadhesh
    JOURNAL OF SOLAR ENERGY ENGINEERING-TRANSACTIONS OF THE ASME, 2020, 142 (03):
  • [28] Thermal performance of an evacuated tube solar collector with inserted baffles for air heating applications
    Kumar, A. Veera
    Arjunan, T. V.
    Seenivasan, D.
    Venkatramanan, R.
    Vijayan, S.
    SOLAR ENERGY, 2021, 215 : 131 - 143
  • [29] Comparative exergy and economic analyses of single slope solar desalination unit combined with concentrator integrated evacuated collectors
    Singh, Ajay Raj
    Agarwal, Alka Bani
    Singh, Desh Bandhu
    DESALINATION AND WATER TREATMENT, 2024, 318
  • [30] Experimental investigation of a solar-heated direct contact membrane distillation system using evacuated tube collectors
    Bamasag, Ahmad
    Alqahtani, Talal
    Sinha, Shahnawaz
    Ghaffour, Noreddine
    Phelan, Patrick
    DESALINATION, 2020, 487