A Single-Channel Non-Orthogonal I/Q RF Sensor for Non-Contact Monitoring of Vital Signs

被引:0
|
作者
Bo, Hongrui [1 ]
Xu, Lisheng [1 ]
Hao, Liling [1 ]
Dou, Yuanzhu [2 ]
Zhao, Lei [3 ]
Yu, Wenhua [3 ]
机构
[1] Northeastern Univ, Dept Elect Engn, Sinodutch Biomed & Informat Engn Sch, Shenyang 110819, Liaoning, Peoples R China
[2] XIKANG ALPS Technol Co Ltd, Shenyang 110179, Liaoning, Peoples R China
[3] Jiangsu Normal Univ, Sch Math & Stat, Ctr Computat Sci & Engn, Xuzhou, Peoples R China
基金
中国国家自然科学基金;
关键词
Non-contact RF sensor; non-orthogonal I/Q signals; vital signs monitoring; Yagi antenna; QUASI-YAGI ANTENNA; RADAR; MICROSTRIP; BALUN;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
In order to remotely monitor the activities of heartbeat, respiration and body movement, this article designed and implemented a single-channel non-orthogonal in-phase/quadrature (I/Q) RF sensor, which works at the central frequency of 2.4 GHz. The designed RF sensor is based on a printed circuit board (PCB) antenna. Taking into account low cost, simple structure and easy fabrication, the antenna is designed and implemented with a special broad-band microstrip-tocoplanar strip line Balun structure by combining the transmitter with the receiver on a PCB to form one single antenna system. The gain of the sensor is 7.7 dB. The return loss is -22.7 dB at 2.4 GHz and the directionality of the antenna is satisfactory for monitoring vital signs. It has been validated that the designed sensor can detect the respiration, heartbeat and body movement accurately in comparison with the signals acquired by respiration sensor and pulse sensor.
引用
收藏
页码:603 / 611
页数:9
相关论文
共 50 条
  • [41] Simultaneous measurements of multiple vital signs using non-contact frequency modulated continuous wave radar monitoring
    Al Ahmad, Mahmoud
    Olule, Lillian Joyce Among
    ALEXANDRIA ENGINEERING JOURNAL, 2023, 71 : 609 - 617
  • [42] Sparsity-Based Multi-Person Non-Contact Vital Signs Monitoring via FMCW Radar
    Eder, Yonathan
    Eldar, Yonina C.
    IEEE JOURNAL OF BIOMEDICAL AND HEALTH INFORMATICS, 2023, 27 (06) : 2806 - 2817
  • [43] Non-Contact Monitoring of Human Vital Signs Using FMCW Millimeter Wave Radar in the 120 GHz Band
    Lv, Wenjie
    He, Wangdong
    Lin, Xipeng
    Miao, Jungang
    SENSORS, 2021, 21 (08)
  • [44] A Novel Microwave Measurement Technique for Non-contact Vital Sign Monitoring
    Sinharay, Arijit
    Das, Rajat
    Seth, Sayan
    2018 IEEE SENSORS, 2018, : 1515 - 1518
  • [45] Estimating vital signs through non-contact video-based approaches: A Survey
    Sinhal, Ruchika
    Singh, Kavita
    Shankar, Anuraj
    2017 INTERNATIONAL CONFERENCE ON RECENT INNOVATIONS IN SIGNAL PROCESSING AND EMBEDDED SYSTEMS (RISE), 2017, : 139 - 141
  • [46] 'No Touch' Vitals: A Pilot Study of Non-contact Vital Signs Acquisition in Exercising Volunteers
    Capraro, Geoffrey
    Etebari, Cameron
    Luchette, Katherine
    Mercurio, Laura
    Merck, Derek
    Kirenko, Ihor
    van Zon, Kees
    Bartula, Marek
    Rocque, Mukul
    Kobayashi, Leo
    2018 IEEE BIOMEDICAL CIRCUITS AND SYSTEMS CONFERENCE (BIOCAS): ADVANCED SYSTEMS FOR ENHANCING HUMAN HEALTH, 2018, : 631 - 634
  • [47] A non-contact lie detector using Radar Vital Signs Monitor (RVSM) technology
    Geisheimer, J
    Greneker, EF
    IEEE AEROSPACE AND ELECTRONIC SYSTEMS MAGAZINE, 2001, 16 (08) : 10 - 14
  • [48] Non-contact sensor for monitoring catenary-pantograph interaction
    Luna Vazquez, C.A.
    IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS (ISIE 2010), 2010, : 482 - 487
  • [49] A Feasibility Study of Remote Non-Contact Vital Signs (NCVS) Monitoring in a Clinic Using a Novel Sensor Realized by Software-Defined Radio (SDR)
    Liu, Yang
    Sweeney, Clint
    Mayeda, Jill C.
    Lopez, Jerry
    Lie, Paul E.
    Nguyen, Tam Q.
    Lie, Donald Y. C.
    BIOSENSORS-BASEL, 2023, 13 (02):
  • [50] An Innovative Non-Contact ECG Sensor for Monitoring Heart Disease
    Sun, Ye
    Yu, Xiong
    Berilla, Jim
    SENSING TECHNOLOGIES FOR GLOBAL HEALTH, MILITARY MEDICINE, DISASTER RESPONSE, AND ENVIRONMENTAL MONITORING AND BIOMETRIC TECHNOLOGY FOR HUMAN IDENTIFICATION VIII, 2011, 8029