Experimental investigation on non-boiling heat transfer of two-component air-oil and air-water slug flow in horizontal pipes

被引:25
作者
Dong, Chuanshuai [1 ,2 ,3 ]
Lu, Lin [2 ]
Wang, Xin [3 ]
机构
[1] South China Univ Technol, Sch Chem & Chem Engn, Guangzhou 510640, Guangdong, Peoples R China
[2] Hong Kong Polytech Univ, Dept Bldg Serv Engn, Hong Kong 999077, Peoples R China
[3] China Univ Petr, Coll Pipeline & Civil Engn, Prov Key Lab Oil & Gas Storage & Transportat, Qingdao 266580, Shandong, Peoples R China
基金
中国国家自然科学基金; 中国博士后科学基金;
关键词
Slug flow; Heat transfer coefficient; Pressure drop multiplier; Chilton-Colburn analogy; 2-PHASE FLOW; PRESSURE-DROP; LIQUID FLOWS;
D O I
10.1016/j.ijmultiphaseflow.2019.07.004
中图分类号
O3 [力学];
学科分类号
08 ; 0801 ;
摘要
Gas-liquid slug flow in horizontal pipes occurs frequently in industrial applications and its heat transfer characteristics are very important but complicated due to the intermittent flow structures. This paper aims at investigating the heat transfer mechanism of both air-oil and air-water slug flow in horizontal pipes. An experimental setup was fabricated to investigate the flow and heat transfer characteristics of air-oil and air-water slug flow under cooling conditions in horizontal pipes. The test section was made of a copper pipe with I.D. of 26 mm and a polyvinyl chloride pipe with I.D. of 63mm using concentric geometry. The effect of flow parameters, such as liquid flow rate, gas flow rate, two-phase pressure drop multiplier, void fraction and slug frequency on heat transfer of gas-liquid slug flow was comprehensively investigated. The heat transfer coefficient of two-phase flow was significantly improved by the introduction of air and the maximum two-phase heat transfer enhancement ratio for air-water and air-oil flow were 150% and 300%, respectively. The circumferential temperature distribution and local heat transfer coefficient were also investigated. The local heat transfer coefficient at the bottom was around 25% higher than that at the top due to the uneven distribution of liquid and gas inside the pipe. Finally, a semi-empirical heat transfer correlation for gas-liquid slug flow was developed based on Reynolds and Chilton-Colburn analogies. The newly developed correlation predicts 96% of the present experimental two-phase heat transfer data within +/- 20% error and the mean relative deviations of the correlations are estimated to be -2.02% and +2.85% for Re-f <= 2300 and Re-f > 2300, respectively. This research helps researchers and engineers to better understand the heat transfer mechanism of gas-liquid slug flow. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:28 / 41
页数:14
相关论文
共 36 条
[1]   Flow structure in horizontal oil-water flow [J].
Angeli, P ;
Hewitt, GF .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2000, 26 (07) :1117-1140
[2]  
[Anonymous], 2009, Experimentation, Validation, and Uncertainty Analysis for Engineers
[3]   Modeling the scooping phenomenon for the heat transfer in liquid-gas horizontal slug flows [J].
Bassani, Carlos L. ;
Pereira, Fernando H. G. ;
Barbuto, Fausto A. A. ;
Morales, Rigoberto E. M. .
APPLIED THERMAL ENGINEERING, 2016, 98 :862-871
[4]   Flow regime independent, high resolution multi-field modelling of near-horizontal gas-liquid flows in pipelines [J].
Bonizzi, M. ;
Andreussi, P. ;
Banerjee, S. .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2009, 35 (01) :34-46
[5]   Design Options for Avoiding Hydrates in Deep Offshore Production [J].
Cardoso, Carlos A. B. R. ;
Goncalves, Marcelo A. L. ;
Camargo, Ricardo M. T. .
JOURNAL OF CHEMICAL AND ENGINEERING DATA, 2015, 60 (02) :330-335
[6]   Characterization of slug initiation for horizontal air-water two-phase flow [J].
Conte, Marco G. ;
Hegde, Govind A. ;
da Silva, Marco J. ;
Sum, Amadeu K. ;
Morales, Rigoberto E. M. .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2017, 87 :80-92
[7]   Correlation of heat transfer coefficient for two-component two-phase slug flow in a vertical pipe [J].
Dong, Chuanshuai ;
Hibiki, Takashi .
INTERNATIONAL JOURNAL OF MULTIPHASE FLOW, 2018, 108 :124-139
[8]   Heat transfer correlation for two-component two-phase slug flow in Check for horizontal pipes [J].
Dong, Chuanshuai ;
Hibiki, Takashi .
APPLIED THERMAL ENGINEERING, 2018, 141 :866-876
[9]   Experimental study on dehumidification performance enhancement by TiO2 superhydrophilic coating for liquid desiccant plate dehumidifiers [J].
Dong, Chuanshuai ;
Lu, Lin ;
Wen, Tao .
BUILDING AND ENVIRONMENT, 2017, 124 :219-231
[10]  