The Cost-Effectiveness of Dual Mobility Implants for Primary Total Hip Arthroplasty: A Computer-Based Cost-Utility Model

被引:49
作者
Barlow, Brian T. [1 ]
McLawhorn, Alexander S. [1 ,2 ]
Westrich, Geoffrey H. [1 ,2 ]
机构
[1] Hosp Special Surg, Dept Orthoped Surg, 535 E 70th St, New York, NY 10021 USA
[2] Weill Cornell Med Coll, Dept Orthoped Surg, New York, NY 10065 USA
关键词
TOTAL KNEE ARTHROPLASTY; FOLLOW-UP; UNITED-STATES; PREVENT DISLOCATION; INTRAPROSTHETIC DISLOCATION; JOINT ARTHROPLASTY; YOUNGER PATIENTS; FEMORAL-NECK; REPLACEMENT; REVISION;
D O I
10.2106/JBJS.16.00109
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Dislocation remains a clinically important problem following primary total hip arthroplasty, and it is a common reason for revision total hip arthroplasty. Dual mobility (DM) implants decrease the risk of dislocation but can be more expensive than conventional implants and have idiosyncratic failure mechanisms. The purpose of this study was to investigate the cost-effectiveness of DM implants compared with conventional bearings for primary total hip arthroplasty. Methods: Markov model analysis was conducted from the societal perspective with use of direct and indirect costs. Costs, expressed in 2013 U.S. dollars, were derived from the literature, the National Inpatient Sample, and the Centers for Medicare & Medicaid Services. Effectiveness was expressed in quality-adjusted life years (QALYs). The model was populated with health state utilities and state transition probabilities derived from previously published literature. The analysis was performed for a patient's lifetime, and costs and effectiveness were discounted at 3% annually. The principal outcome was the incremental cost-effectiveness ratio (ICER), with a willingness-to-pay threshold of $100,000/QALY. Sensitivity analyses were performed to explore relevant uncertainty. Results: In the base case, DM total hip arthroplasty showed absolute dominance over conventional total hip arthroplasty, with lower accrued costs ($39,008 versus $40,031 U.S. dollars) and higher accrued utility (13.18 versus 13.13 QALYs) indicating cost-savings. DM total hip arthroplasty ceased being cost-saving when its implant costs exceeded those of conventional total hip arthroplasty by $ 1,023, and the cost-effectiveness threshold for DM implants was $ 5,287 greater than that for conventional implants. DM was not cost-effective when the annualized incremental probability of revision from any unforeseen failure mechanism or mechanisms exceeded 0.29%. The probability of intraprosthetic dislocation exerted the most influence on model results. Conclusions: This model determined that, compared with conventional bearings, DM implants can be cost-saving for routine primary total hip arthroplasty, from the societal perspective, if newer-generation DM implants meet specific economic and clinical benchmarks. The differences between these thresholds and the performance of other contemporary bearings were frequently quite narrow. The results have potential application to the postmarket surveillance of newer-generation DM components.
引用
收藏
页码:768 / 777
页数:10
相关论文
共 77 条
[1]   Dual mobility cups hip arthroplasty as a treatment for displaced fracture of the femoral neck in the elderly. A prospective, systematic, multicenter study with specific focus on postoperative dislocation [J].
Adam, P. ;
Philippe, R. ;
Ehlinger, M. ;
Roche, O. ;
Bonnomet, F. ;
Mole, D. ;
Fessy, M. -H. .
ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2012, 98 (03) :296-300
[2]  
[Anonymous], 2011, CURRENT POPULATION R
[3]  
Arias Elizabeth, 2014, Natl Vital Stat Rep, V62, P1
[4]  
Australian Orthopaedic Association National Joint Replacement Registry, 2014, HIP KNEE ARTHR ANN R
[5]   Early Intraprosthetic Dislocation in a Revision Dual-mobility Hip Prosthesis [J].
Banka, Trevor R. ;
Ast, Michael P. ;
Parks, Michael L. .
ORTHOPEDICS, 2014, 37 (04) :E395-E397
[6]   Economic Benefit to Society at Large of Total Knee Arthroplasty in Younger Patients A Markov Analysis [J].
Bedair, Hany ;
Cha, Thomas D. ;
Hansen, Viktor J. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2014, 96A (02) :119-126
[7]   Mortality after total hip replacement surgery A SYSTEMATIC REVIEW [J].
Berstock, J. R. ;
Beswick, A. D. ;
Lenguerrand, E. ;
Whitehouse, M. R. ;
Blom, A. W. .
BONE & JOINT RESEARCH, 2014, 3 (06) :175-182
[8]   Primary total hip arthroplasty with dual mobility socket to prevent dislocation: a 22-year follow-up of 240 hips [J].
Boyer, Bertrand ;
Philippot, Remi ;
Geringer, Jean ;
Farizon, Frederic .
INTERNATIONAL ORTHOPAEDICS, 2012, 36 (03) :511-518
[9]   Technology assessment and adoption in orthopaedics: Lessons learned [J].
Bozic, Kevin J. ;
Jacobs, Joshua J. .
JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (04) :689-690
[10]   Health State Utility in Patients with Osteoarthritis of the Hip and Total Hip Arthroplasty [J].
Bozic, Kevin J. ;
Chiu, Vanessa W. ;
Slover, James D. ;
Immerman, Igor ;
Kahn, James G. .
JOURNAL OF ARTHROPLASTY, 2011, 26 (06) :129-132