Detection and management of an implantable cardioverter defibrillator lead failure - Incidence and clinical implications

被引:108
作者
Ellenbogen, KA
Wood, MA
Shepard, RK
Clemo, HF
Vaughn, T
Holloman, K
Dow, M
Leffler, J
Abeyratne, A
Verness, D
机构
[1] Virginia Commonwealth Univ, Med Coll Virginia, Div Cardiol, Richmond, VA 23398 USA
[2] Medtronic Inc, Minneapolis, MN USA
关键词
D O I
10.1016/S0735-1097(02)02620-7
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
OBJECTIVES This study evaluated the long-term reliability of an implantable cardioverter defibrillator (ICD) lead to determine the incidence, clinical presentation, and management of lead failure. BACKGROUND Despite recent advances in ICD technology, the long-term reliability of ICD leads remains a significant problem. METHODS Concern about long-term reliability of coaxial polyurethane ICD leads caused us to systematically study all patients implanted with Medtronic (Minneapolis, Minnesota) 6936 lead at our institution. We performed follow-up of 74 patients with 76 ICD leads that were implanted from February 28, 1995 to September 8, 1997. Thirty-seven patients underwent routine clinical ICD follow-up testing and ventricular fibrillation induction to determine the status of their ICD lead after a mean follow-up of 68.6 +/- 8.2 months. RESULTS The lead survival analysis shows a cumulative failure probability of 37% (confidence interval,, 24% to 54%) at 68.6 months. Six patients demonstrated a previously undescribed mode of ICD lead failure: prolonged oversensing immediately after shock therapy. The use of short interval counters to monitor nonphysiologic R-R intervals and the measurement of ring-to-coil impedance detected early lead failures in five patients. CONCLUSIONS This analysis shows: 1) problems with ICD leads may not become apparent until late during follow-up and may become a significant late problem, 2) a "signature" mode of lead failure for the 6936 consisting of oversensing of electrical noise following shocks, 3) early detection of lead failure with a short interval counter algorithm or measurement of ring-to-coil impedance may be clinically useful. (C) 2003 by the American College of Cardiology Foundation.
引用
收藏
页码:73 / 80
页数:8
相关论文
共 24 条
[1]   Insulation lead failure: Is it a matter of insulation coating, venous approach, or both? [J].
Antonelli, D ;
Rosenfeld, T ;
Freedberg, NA ;
Palma, E ;
Gross, JN ;
Furman, S .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1998, 21 (02) :418-421
[2]   Multicenter experience with a pectoral unipolar implantable cardioverter-defibrillator [J].
Bardy, GH ;
Yee, R ;
Jung, W .
JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 1996, 28 (02) :400-410
[3]  
BARDY GH, 2002, PACING CLIN ELECTROP, V24, P578
[4]   Malfunction of endocardial defibrillator leads and lead extraction: where do they meet? [J].
Bracke, FALE ;
Meijer, A ;
van Gelder, LM .
EUROPACE, 2002, 4 (01) :19-24
[5]   Sensing lead failure in implantable defibrillators: A comparison of two commonly used leads [J].
Degeratu, FT ;
Khalighi, K ;
Peters, RW ;
Shorofsky, SR ;
Gold, MR .
JOURNAL OF CARDIOVASCULAR ELECTROPHYSIOLOGY, 2000, 11 (01) :21-24
[6]  
GAHY GJ, 1995, PACING CLIN ELECTROP, V18, P172
[7]   Complications associated with pectoral implantation of cardioverter defibrillators [J].
Gold, MR ;
Peters, RW ;
Johnson, JW ;
Shorofsky, SR .
PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 1997, 20 (01) :208-211
[8]   ACC/AHA Guidelines for Implantation of Cardiac Pacemakers and Antiarrhythmia Devices: Executive summary - A report of the American College of Cardiology American Heart Association Task Force on Practice Guidelines (Committee on Pacemaker Implantation) [J].
Gregoratos, G ;
Cheitlin, MD ;
Conill, A ;
Epstein, AE ;
Fellows, C ;
Ferguson, TB ;
Freedman, RA ;
Hlatky, MA ;
Naccarelli, GV ;
Saksena, S ;
Schlant, RC ;
Silka, MJ .
CIRCULATION, 1998, 97 (13) :1325-1335
[9]  
GUNDERSON B, 2000, PACING CLIN ELECTROP, V23, P591
[10]  
HAUSER RG, 2002, CLIN ELECTROPHYSIOL, V25, P879