Optimizing femur symmetry judgment using three-dimensional data correction scheme in fractures of the proximal femur

被引:2
作者
Zhang, Wenxi [1 ]
Liu, Jie [1 ]
Jiang, Junfeng [2 ]
Zhou, Jinhua [1 ]
机构
[1] Peoples Hosp Liyang, Dept Orthopaed, Changzhou, Jiangsu, Peoples R China
[2] Hohai Univ, Coll IOT Engn, Changzhou, Peoples R China
来源
INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED | 2022年 / 53卷 / 06期
关键词
3D printing; Intertrochanteric fractures; Symmetry; Internal fixation; Dihedral angle; LOCKING PLATE; FIXATION; EXPRESSION;
D O I
10.1016/j.injury.2022.02.051
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: The application of the 3D printing mirror image model is based on the symmetry of the limbs. Different from image fusion to judge the similarity, based on the commonality of the limb morphology of the same organism and the isotropic of the long bone cross-section, the symmetry of the femur has been determined by calculating the dimension difference of the corresponding cross-section of the non-fractured area. However, the previous version used equidistant cross-sections for measurement and two-dimensional data correction, and there were problems with insufficient reliability and data failure. The purpose of this study is to achieve a more accurate and universal symmetry verification scheme for bilateral tubular bones through an improved method. Methods: Forty-five imaging data of proximal femoral fracture and osteopathy were selected from October 2015 to September 2017. 10%, 30%, and 50% of the full-length of the bilateral femur is sliced to judge the similarity between paired femurs. Long and short axes of the bilateral femoral cross-sections on the two-dimensional slices were measured and compared. A stylized trigonometric were used to correct the measured axes lengths such that they more closely match with measurements taken from slices perpendicular to femoral shaft axis.Results: 540 valid data items from the long axis and short axis of the bilateral side of the distal femur were obtained, and 192 of these were corrected. There were no significant differences between the left and right of the long and short axis of each cross-section in paired cases ( P > 0.05).Conclusions: This study have demonstrated symmetricity of the left and right femurs. The availability of CT data at any position of the patient's lower limbs is realized through replacing the previous "twodimensional data correction" with "three-dimensional data correction".(c) 2022 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2172 / 2179
页数:8
相关论文
共 23 条
  • [1] Volume fusion of CT images to measure femoral symmetricity
    Bakhshayesh, Peyman
    Sandberg, Olof
    Kumar, Vishal
    Ali, Adam
    Enocson, Anders
    [J]. SURGICAL AND RADIOLOGIC ANATOMY, 2020, 42 (06) : 635 - 639
  • [2] Randomized Trial of Reamed and Unreamed Intramedullary Nailing of Tibial Shaft Fractures
    Bhandari, Mohit
    Guyatt, Gordon
    Tornetta, Paul, III
    Schemitsch, Emil H.
    Swiontkowski, Marc
    Sanders, David
    Walter, Stephen D.
    [J]. JOURNAL OF BONE AND JOINT SURGERY-AMERICAN VOLUME, 2008, 90A (12) : 2567 - 2578
  • [3] Recruitment of mesenchymal stem cells and expression of TGF-β1 and VEGF in the early stage of shock wave-promoted bone regeneration of segmental defect in rats
    Chen, YJ
    Wurtz, T
    Wang, CJ
    Kuo, YR
    Yang, KD
    Huang, HC
    Wang, FS
    [J]. JOURNAL OF ORTHOPAEDIC RESEARCH, 2004, 22 (03) : 526 - 534
  • [4] Preshaping Plates for Minimally Invasive Fixation of Calcaneal Fractures Using a Real-Size 3D-Printed Model as a Preoperative and Intraoperative Tool
    Chung, Kook Jin
    Hong, Do Yeong
    Kim, Yong Tae
    Yang, Ik
    Park, Yong Wook
    Kim, Hyong Nyun
    [J]. FOOT & ANKLE INTERNATIONAL, 2014, 35 (11) : 1231 - 1236
  • [5] A Data-Driven Approach for Assembling Intertrochanteric Fractures by Axis-Position Alignment
    Deng, Ziyue
    Jiang, Junfeng
    Liu, Hongwei
    Cheng, Zhengming
    Huang, Rui
    Zhang, Wenxi
    He, Kunjin
    [J]. IEEE ACCESS, 2020, 8 (08): : 137549 - 137563
  • [6] Side-to-side variation in normal femoral morphology: 3D CT analysis of 122 femurs
    Dimitriou, D.
    Tsai, T. -Y.
    Yue, B.
    Rubash, H. E.
    Kwon, Y. -M.
    Li, G.
    [J]. ORTHOPAEDICS & TRAUMATOLOGY-SURGERY & RESEARCH, 2016, 102 (01) : 91 - 97
  • [7] Bilateral Symmetrical Comparison of Femoral and Tibial Anatomic Features
    Eckhoff, Donald G.
    Jacofsky, David J.
    Springer, Bryan D.
    Dunbar, Michael
    Cherian, Jeffrey J.
    Elmallah, Randa K.
    Mont, Michael A.
    Greene, Kenneth A.
    [J]. JOURNAL OF ARTHROPLASTY, 2016, 31 (05) : 1083 - 1090
  • [8] A 3D-CT Analysis of Femoral Symmetry-Surgical Implications
    Ferras-Tarrago, Joan
    Sanchis-Alfonso, Vicente
    Ramirez-Fuentes, Cristina
    Rosello-Anon, Alejandro
    Baixauli-Garcia, Francisco
    [J]. JOURNAL OF CLINICAL MEDICINE, 2020, 9 (11) : 1 - 10
  • [9] A Biomechanical Comparison of a Locking Plate, a Nail, and a 95° Angled Blade Plate for Fixation of Subtrochanteric Femoral Fractures
    Forward, Daren P.
    Doro, Christopher J.
    O'Toole, Robert V.
    Kim, Hyunchul
    Floyd, John C. P.
    Sciadini, Marcus F.
    [J]. JOURNAL OF ORTHOPAEDIC TRAUMA, 2012, 26 (06) : 334 - 340
  • [10] Multi-atlas automatic positioning of anatomical landmarks
    Jacinto, Hector
    Valette, Sebastien
    Prost, Remy
    [J]. JOURNAL OF VISUAL COMMUNICATION AND IMAGE REPRESENTATION, 2018, 50 : 167 - 177