Pressurized SOFC System Fuelled by Biogas: Control Approaches and Degradation Impact

被引:8
作者
Ferrari, Mario L. [1 ]
Zaccaria, Valentina [2 ]
Kyprianidis, Konstantinos [2 ]
机构
[1] Univ Genoa, Thermochem Power Grp TPG, I-16145 Genoa, Italy
[2] Malardalen Univ MDH, S-72123 Vasteras, Sweden
来源
JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME | 2021年 / 143卷 / 06期
基金
瑞典研究理事会;
关键词
hybrid system; SOFC; biogas; CYCLES IRSOFC-GT; PART II; CELL; MODEL;
D O I
10.1115/1.4048653
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
This paper shows control approaches for managing a pressurized solid oxide fuel cell (SOFC) system fuelled by biogas. This is an advanced solution to integrate the high efficiency benefits of a pressurized SOFC with a renewable source. The operative conditions of these analyses are based on the matching with an emulator rig including a T100 machine for tests in cyber-physical mode. So, this paper presents a real-time model including the fuel cell, the off-gas burner (OFB), and the recirculation lines. Although the microturbine components are planned to be evaluated with the hardware devices, the model includes also the T100 expander for machine control reasons. The simulations shown in this paper regard the assessment of an innovative control tool based on the model predictive control (MPC) technology. This controller and an additional tool based on the coupling of MPC and proportional integral derivative (PID) approaches were assessed against the application of PID controllers. The control targets consider both steady-state and dynamic aspects. Moreover, different control solutions are presented to operate the system during fuel cell degradation. The results include the system response to load variations, and SOFC voltage decrease. Considering the simulations including SOFC degradation, the MPC was able to decrease the thermal stress, but it was not able to compensate the degradation. On the other hand, the tool based on the coupling of the MPC and the PID approaches produced the best results in terms of set-point matching, and SOFC thermal stress containment.
引用
收藏
页数:8
相关论文
共 28 条
  • [1] Agnew G.D., GT200569122 ASME, DOI [10.1115/GT2005-69122, DOI 10.1115/GT2005-69122]
  • [2] [Anonymous], 2018, FUEL CELLS B, P6, DOI DOI 10.1016/S1464-2859(18)30045-2
  • [3] Emulator Rig for SOFC Hybrid Systems: Temperature and Power Control with a Real-Time Software
    Caratozzolo, F.
    Ferrari, M. L.
    Traverso, A.
    Massardo, A. F.
    [J]. FUEL CELLS, 2013, 13 (06) : 1123 - 1130
  • [4] Caratozzolo F., 2011, 201154315 ASME, DOI [10.1115/2011-54315, DOI 10.1115/2011-54315]
  • [5] Gas turbine size optimization in a hybrid system considering SOFC degradation
    Cuneo, A.
    Zaccaria, V.
    Tucker, D.
    Sorce, A.
    [J]. APPLIED ENERGY, 2018, 230 : 855 - 864
  • [6] Ferrari M.L., 2009, ICEPAG 2009 NEW PORT
  • [7] Advanced Control System for Grid-Connected SOFC Hybrid Plants: Experimental Verification in Cyber-Physical Mode
    Ferrari, Mario L.
    Rossi, Iacopo
    Sorce, Alessandro
    Massardo, Aristide F.
    [J]. JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2019, 141 (09):
  • [8] Ejector Model for High Temperature Fuel Cell Hybrid Systems: Experimental Validation at Steady-State and Dynamic Conditions
    Ferrari, Mario L.
    Pascenti, Matteo
    Massardo, Aristide F.
    [J]. JOURNAL OF FUEL CELL SCIENCE AND TECHNOLOGY, 2008, 5 (04):
  • [9] Generic Real-Time Modeling of Solid Oxide Fuel Cell Hybrid Systems
    Ghigliazza, Francesco
    Traverso, Alberto
    Massardo, Aristide F.
    Wingate, John
    Ferrari, Mario
    [J]. JOURNAL OF FUEL CELL SCIENCE AND TECHNOLOGY, 2009, 6 (02): : 0213121 - 0213127
  • [10] Teaching and Practicing Model Predictive Control
    Honc, Daniel
    Sharma, Rahul K.
    Abraham, Anuj
    Dusek, Frantisek
    Pappa, Natarajan
    [J]. IFAC PAPERSONLINE, 2016, 49 (06): : 34 - 39