Proximity hybridization-induced competitive rolling circle amplification to construct fluorescent dual-sensor for simultaneous evaluation of glycated and total hemoglobin

被引:10
作者
Chen, Zhao-Peng [1 ]
Su, Ming-Li [1 ]
Chen, Hao-Ran [1 ]
Yuan, Ruo [1 ]
Li, Yan [2 ,3 ]
Liang, Wen-Bin [1 ]
机构
[1] Southwest Univ, Coll Chem & Chem Engn, Key Lab Luminescence Anal & Mol Sensing, Minist Educ, Chongqing 400715, Peoples R China
[2] Army Med Univ, Dept Clin, Chongqing 400038, Peoples R China
[3] Army Med Univ, Mil Lab Med, Coll Med Lab Sci, Chongqing 400038, Peoples R China
关键词
Hemoglobin; Glycated hemoglobin; Proximity hybridization; Rolling circle amplification; IMMUNOSENSOR; MANAGEMENT; HBA(1C);
D O I
10.1016/j.bios.2022.113998
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
The glycated hemoglobin (HbA1c) level, defined as the ratio of HbA1c to total hemoglobin (tHb), has been considered as a standard index for diabetes mellitus diagnosis, avoiding any short-term fluctuation of the blood glucose level. However, it is still a key challenge that some complicated separation procedures are required to detect HbA1c and tHb in a single experiment. Herein, we developed a dual-sensing fluorescent assay for HbA1c and tHb based on proximity hybridization-induced rolling circle amplification (RCA) and T7 exonuclease aided signal cycle to calculate the HbAlc level in one single experiment. Typically, four DNA-tagged probes were used for immunoreactions of anti-HbA1c antibodies (Ab1) and anti-Hb antibodies (Ab2) with HbA1c and Hb, respectively. The RCA1 and RCA2 were induced by the complexes of assistant DNAs and the products of proximity hybridization with anti-HbA1c-DNA1 (2) and anti-Hb-DNA3 (4), respectively. Meanwhile, the tHb in solution could prevent the existing RCA2 based on its competing with Hb-DNA3 for Ab2-DNA4. Thus, RCA1 and RCA2 routes create "signal-on" and "signal-off" readouts, respectively. After the hybridization of signal probes and RCA products, the quenched fluorescence was recovered by the digestion of T7 exonuclease. Under optimized conditions, the method displayed high sensitivity with a limit of detection 2.17 ng/mL and 33.4 ng/mL for HbA1c and tHb, respectively, and the real sample analysis results were found to match well with the theoretical data, holding feasibility for rapid, homogeneous, and easy HbA1c level evaluation and great promise as a potential alternative tool to analyze HbA1c level clinically.
引用
收藏
页数:7
相关论文
共 48 条
[1]   Rapid colorimetric sensing platform for the detection of Listeria monocytogenes foodborne pathogen [J].
Alhogail, Sahar ;
Suaifan, Ghadeer A. R. Y. ;
Zourob, Mohammed .
BIOSENSORS & BIOELECTRONICS, 2016, 86 :1061-1066
[2]   Localized Visualization and Autonomous Detection of Cell Surface Receptor Clusters Using DNA Proximity Circuit [J].
Ang, Yan Shan ;
Li, Jia'En Jasmine ;
Chua, Pei-Jou ;
Ng, Cheng-Teng ;
Bay, Boon-Huat ;
Yung, Lin-Yue Lanry .
ANALYTICAL CHEMISTRY, 2018, 90 (10) :6193-6198
[3]   Boronate-Modified Interdigitated Electrode Array for Selective Impedance-Based Sensing of Glycated Hemoglobin [J].
Boonyasit, Yuwadee ;
Laiwattanapaisal, Wanida ;
Chailapakul, Orawon ;
Emneus, Jenny ;
Heiskanen, Arto R. .
ANALYTICAL CHEMISTRY, 2016, 88 (19) :9582-9589
[4]   An electrochemical biosensor for fructosyl valine for glycosylated hemoglobin detection based on core-shell magnetic bionanoparticles modified gold electrode [J].
Chawla, Sheetal ;
Pundir, Chandra Shekhar .
BIOSENSORS & BIOELECTRONICS, 2011, 26 (08) :3438-3443
[5]   Detection of Total and A1c-Glycosylated Hemoglobin in Human Whole Blood Using Sandwich Immunoassays on Polydimethylsiloxane-Based Antibody Microarrays [J].
Chen, Huang-Han ;
Wu, Chih-Hsing ;
Tsai, Mei-Ling ;
Huang, Yi-Jing ;
Chen, Shu-Hui .
ANALYTICAL CHEMISTRY, 2012, 84 (20) :8635-8641
[6]   Ultrasensitive photoelectrochemical immunosensor of cardiac troponin I detection based on dual inhibition effect of Ag@Cu2O core-shell submicron-particles on CdS QDs sensitized TiO2 nanosheets [J].
Chen, Jie ;
Kong, Ling ;
Sun, Xiaokai ;
Feng, Jinhui ;
Chen, Zhiwei ;
Fan, Dawei ;
Wei, Qin .
BIOSENSORS & BIOELECTRONICS, 2018, 117 :340-346
[7]   Performances of Capillary Electrophoresis and HPLC Methods in HbA1c Determination: Diagnostic Accuracy in HbS and HbD-Iran Variants' Presence [J].
Dessi, Mariarita ;
Pieri, Massimo ;
Pignalosa, Stefano ;
Martino, Francesca Gabriela ;
Zenobi, Rossella .
JOURNAL OF CLINICAL LABORATORY ANALYSIS, 2015, 29 (01) :57-60
[8]   Review of hemoglobin A1c in the management of diabetes [J].
Gallagher, Emily Jane ;
Le Roith, Derek ;
Bloomgarden, Zachary .
JOURNAL OF DIABETES, 2009, 1 (01) :9-17
[9]   Proximity hybridization-regulated electrogenerated chemiluminescence bioassay of α-fetoprotein via target-induced quenching mechanism [J].
Gao, Hongfang ;
Wang, Xiaofei ;
Li, Man ;
Qi, Honglan ;
Gao, Qiang ;
Zhang, Chengxiao .
BIOSENSORS & BIOELECTRONICS, 2017, 98 :62-67
[10]   Separation detection of hemoglobin and glycated hemoglobin fractions in blood using the electrochemical microfluidic channel with a conductive polymer composite sensor [J].
Hossain, M. D. Mozammal ;
Moon, Jong-Min ;
Gurudatt, N. G. ;
Park, Deog-Su ;
Choi, Cheol Soo ;
Shim, Yoon-Bo .
BIOSENSORS & BIOELECTRONICS, 2019, 142