Use of contrast harmonic ultrasound for the diagnosis of congenital portosystemic shunts in three dogs

被引:31
作者
Salwei, RM [1 ]
O'Brien, RT [1 ]
Matheson, JS [1 ]
机构
[1] Univ Wisconsin, Sch Vet Med, Dept Surg Sci, Madison, WI 53706 USA
关键词
harmonic sonography; dog; liver; shunt; ultrasound contrast;
D O I
10.1111/j.1740-8261.2003.tb00459.x
中图分类号
S85 [动物医学(兽医学)];
学科分类号
0906 ;
摘要
Contrast harmonic ultrasound was used to determine macrovascular and perfusion patterns in three dogs with congenital extrahepatic solitary portosystemic shunts (PSS). With coded harmonic angiographic ultrasound, the size and tortuosity of the hepatic arteries were subjectively increased. Single pulse intermittent low-amplitude harmonic perfusion imaging provided contrast enhancement time-intensity curves from regions of interest in the liver. Mean ( standard deviation) peak perfusion times of dogs with PSS were significantly shorter (p = 0.01; 7.0 +/- 2.0 s) than reported in normal dogs (22.8 +/- 6.8 s). The contrast inflow slope for the dogs with PSS (14.6 +/- 3.7 pixel intensity units [PIU] was significantly (p = 0.05) larger than reported for normal dogs (3.6 +/- 1.4 PIU/s). These results indicate that combined coded harmonic angiographic and contrast harmonic perfusion sonography can be used to detect increased hepatic arterial blood flow as an indicator of PSS in dogs.
引用
收藏
页码:301 / 305
页数:5
相关论文
共 25 条
[1]  
BERRY CR, 1996, HDB VET NUCL MED
[2]  
Burns PN, 1996, CLIN RADIOL, V51, P50
[3]   Hepatocellular carcinoma - Contrast enhancement with Levovist [J].
Choi, BI ;
Kim, AY ;
Lee, JY ;
Kim, KW ;
Lee, KH ;
Kim, TK ;
Han, JK .
JOURNAL OF ULTRASOUND IN MEDICINE, 2002, 21 (01) :77-84
[4]   PER RECTAL PORTAL SCINTIGRAPHY USING 99M TECHNETIUM PERTECHNETATE TO DIAGNOSE PORTOSYSTEMIC SHUNTS IN DOGS AND CATS [J].
DANIEL, GB ;
BRIGHT, R ;
OLLIS, P ;
SHULL, R .
JOURNAL OF VETERINARY INTERNAL MEDICINE, 1991, 5 (01) :23-27
[5]   COMPARISON OF PER-RECTAL PORTAL SCINTIGRAPHY USING TC-99M PERTECHNETATE TO MESENTERIC INJECTION OF RADIOACTIVE MICROSPHERES FOR QUANTIFICATION OF PORTOSYSTEMIC SHUNTS IN AN EXPERIMENTAL DOG-MODEL [J].
DANIEL, GB ;
BRIGHT, R ;
MONNET, E ;
OLLIS, P .
VETERINARY RADIOLOGY, 1990, 31 (04) :175-181
[6]   Basic acoustic properties of microbubbles [J].
de Jong, N ;
Bouakaz, A ;
Frinking, P .
ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2002, 19 (03) :229-240
[7]  
Di Giulio G, 1997, Radiol Med, V93, P225
[8]  
HOLT DE, 1995, J AM VET MED ASSOC, V207, P1190
[9]  
HORNOF WJ, 1983, J AM VET MED ASSOC, V182, P44
[10]   Enhancement of hepatic hemangiomas with Levovist on coded harmonic angiographic ultrasonography [J].
Kim, JH ;
Kim, TK ;
Kim, BS ;
Eun, HW ;
Kim, PN ;
Lee, MG ;
Ha, HK .
JOURNAL OF ULTRASOUND IN MEDICINE, 2002, 21 (02) :141-148