Modeling Real-World System Geometry and Detector Response within a High-Throughput X-Ray Simulation Framework

被引:3
|
作者
Coccarelli, David [1 ]
Hurlock, Ava [1 ]
Royse, Camen [1 ]
Carpenter, Joshua H. [1 ]
Greenberg, Joel A. [1 ]
Johnson, Eric [2 ]
Bosch, Carl [2 ]
Gehm, Michael E. [1 ]
机构
[1] Duke Univ, ECE Dept, Durham, NC 27708 USA
[2] SureScan Corp, Binghamton, NY USA
来源
ANOMALY DETECTION AND IMAGING WITH X-RAYS (ADIX) IV | 2019年 / 10999卷
关键词
Simulation; Hardware Characterization; X-Ray Imaging; X-Ray System; Material Classification; Automatic Threat Recognition; TUBE;
D O I
10.1117/12.2518870
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Simulations of x-ray scanners have the potential to aid in the design and understanding of system performance. We have previously shown the usefulness of a high-throughput simulation framework in pursuit of information theoretic analysis of x-ray systems employed for aviation security. While conclusions drawn from these studies were able to inform design decisions, they were limited to generic system geometries and naive interpretations of detector responses. In collaboration with the SureScan Corporation, we have since expanded our analysis efforts to include their real world system geometry and detector response. To this extent, we present our work to simulate the SureScan x1000 scanner, a fixed-gantry spectral CT system for checked baggage. Our simulations are validated in terms of system geometry and spectral response. We show how high fidelity simulations are used with SureScan reconstruction software to analyze virtual baggage. The close match between simulated and real world measurements means that simulation can be a powerful tool in system development. Moreover, the close match allows simulation to be a straightforward avenue for producing large labeled datasets needed in machine learning approaches to automatic threat recognition (ATR).
引用
收藏
页数:9
相关论文
共 12 条
  • [1] Modeling realistic virtual objects within a high-throughput X-ray simulation framework
    Coccarelli, David
    Gehm, Michael E.
    Greenberg, Joel A.
    ANOMALY DETECTION AND IMAGING WITH X-RAYS (ADIX) V, 2020, 11404
  • [2] Simulation of X-ray and gamma ray detector response and spectral deconvolution
    Sinha, Srikanta
    ADVANCES IN SPACE RESEARCH, 2006, 38 (12) : 3005 - 3007
  • [3] Simulation of X-ray and gamma ray detector response and spectral deconvolution
    Sinha, Srikanta
    SPECTRA AND TIMING OF COMPACT X-RAY BINARIES, 2006, 38 (12): : 3005 - 3007
  • [4] Evolution of the X-ray Binary System Sco X-1 within the Framework of the Induced Stellar Wind Model
    Fedorova, A. V.
    Tutukov, A. V.
    ASTRONOMY REPORTS, 2022, 66 (11) : 925 - 935
  • [5] Evolution of the X-ray Binary System Sco X-1 within the Framework of the Induced Stellar Wind Model
    A. V. Fedorova
    A. V. Tutukov
    Astronomy Reports, 2022, 66 : 925 - 935
  • [6] Rate-distortion tradeoff to optimize high-throughput phenotyping systems. Application to X-ray images of seeds
    Belin, E.
    Rousseau, D.
    Lechappe, J.
    Langlois-Meurinne, M.
    Duerr, C.
    COMPUTERS AND ELECTRONICS IN AGRICULTURE, 2011, 77 (02) : 188 - 194
  • [7] Modeling Technique for Optimizing Simulation Objective Function Based on Key Parameters of the X-ray Imaging System
    Gao, Zhiyu
    Lan, Haibin
    Zhang, Changsheng
    Huang, Yao
    Fu, Jian
    PROCEEDINGS OF THE 2024 THE 7TH INTERNATIONAL CONFERENCE ON MACHINE VISION AND APPLICATIONS, ICMVA 2024, 2024, : 139 - 144
  • [8] Simulation and measurements of the internal electric field of a CZT (or CdTe) detector under high X-ray flux for Medical Imaging
    Alirol, Olivier
    Glasser, Francis
    d'Aillon, Eric Gros
    Tabary, Joachim
    2009 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-5, 2009, : 2460 - 2464
  • [9] High-speed multi-beam X-ray imaging using a lens coupling detector system
    Shirasawa, Tetsuroh
    Xiaouyu, Liang
    Voegeli, Wolfgang
    Arakawa, Etsuo
    Kajiwara, Kentaro
    Yashiro, Wataru
    APPLIED PHYSICS EXPRESS, 2020, 13 (07)
  • [10] High-resolution high-efficiency X-ray imaging system based on the in-line Bragg magnifier and the Medipix detector
    Vagovic, Patrik
    Korytar, Dusan
    Cecilia, Angelica
    Hamann, Elias
    Sveda, Libor
    Pelliccia, Daniele
    Haertwig, Juergen
    Zaprazny, Zdenko
    Oberta, Peter
    Dolbnya, Igor
    Shawney, Kawal
    Fleschig, Uwe
    Fiederle, Michael
    Baumbach, Tilo
    JOURNAL OF SYNCHROTRON RADIATION, 2013, 20 : 153 - 159