Using a plastic sheet to prevent the risk of contamination of the burn wound during the shower

被引:7
作者
Akin, S [1 ]
Özcan, M [1 ]
机构
[1] Uludag Univ, Fac Med, Burn Ctr, Dept Plast & Reconstruct Surg, TR-16059 Gorukle, Bursa, Turkey
关键词
hydrotherapy; showering contamination; plastic sheet; shower trolley;
D O I
10.1016/S0305-4179(02)00311-X
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
The shower technique for hydrotherapy was used in the treatment of the burn patients in our burn center. Before showering, the shower trolley (stretcher) was draped with a sterilized disposable plastic sheet to decrease the potential for seeding surface bacteria to open burn wounds. The patients were washed on the draped shower trolley. Samples for culture were taken from the surface of the shower trolley (stretcher) before it was draped with the sterilized disposable plastic sheet following the treatment of a patient. The samples were taken once a week for the first 6 months and only once a month for the last 42 months. At the period of 48 months (4 years), a total of 67 samples were obtained. Results Of Cultures of all the samples were negative. No patients were contaminated from the surface of the shower trolley during the shower. The use of the sterilized disposable plastic sheet proved to be a most effective procedure to decrease the risk of contamination between patients during the shower. (C) 2003 Elsevier Science Ltd and ISBI. All rights reserved.
引用
收藏
页码:280 / 283
页数:4
相关论文
共 7 条
[1]   2 SOURCES OF CONTAMINATION OF A HYDROTHERAPY POOL BY ENVIRONMENTAL ORGANISMS [J].
ASPINALL, ST ;
GRAHAM, R .
JOURNAL OF HOSPITAL INFECTION, 1989, 14 (04) :285-292
[2]   Outbreak of severe Pseudomonas aeruginosa infections caused by a contaminated drain in a whirlpool bathtub [J].
Berrouane, YF ;
McNutt, LA ;
Buschelman, BJ ;
Rhomberg, PR ;
Sanford, MD ;
Hollis, RJ ;
Pfaller, MA ;
Herwaldt, LA .
CLINICAL INFECTIOUS DISEASES, 2000, 31 (06) :1331-1337
[3]   WHIRLPOOL OPERATION AND THE PREVENTION OF INFECTION [J].
DAVIS, BJ .
INFECTION CONTROL AND HOSPITAL EPIDEMIOLOGY, 1985, 6 (10) :394-397
[4]   An outbreak of methicillin resistant Staphylococcus aureus on a burn unit:: potential role of contaminated hydrotherapy equipment [J].
Embil, JM ;
McLeod, JA ;
Al-Barrak, AM ;
Thompson, GM ;
Aoki, FY ;
Witwicki, EJ ;
Stranc, MF ;
Kabani, AM ;
Nicoll, DR ;
Nicólle, LE .
BURNS, 2001, 27 (07) :681-688
[5]   PSEUDOMONAS-AERUGINOSA AND WHIRLPOOL BATHS [J].
FALLON, RJ .
LANCET, 1995, 346 (8978) :841-841
[6]  
HEGGERS J, TOTAL BURN CARE, P121
[7]   Risk of contamination of the wound in a hydrotherapeutic tank [J].
Stanwood, W ;
Pinzur, MS .
FOOT & ANKLE INTERNATIONAL, 1998, 19 (03) :173-176