Determination of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans, and dioxin-like polychlorinated biphenyls in human serum using programmable-temperature vaporization gas chromatography with high-resolution mass spectrometry

被引:7
作者
Zhang, Lei [1 ,2 ]
Zhong, Yuxin [3 ,4 ]
Liu, Xin [1 ,2 ,5 ]
Bao, Yan [1 ,2 ]
Zhao, Yunfeng [1 ,2 ]
Wu, Yongning [1 ,2 ]
Cai, Zongwei [6 ]
Li, Jingguang [1 ,2 ]
机构
[1] Minist Hlth CFSA, Key Lab Food Safety Risk Assessment, Room 203,7 Panjiayuan Nanli, Beijing 10002, Peoples R China
[2] China Natl Ctr Food Safety Risk Assessment, Room 203,7 Panjiayuan Nanli, Beijing 10002, Peoples R China
[3] Chinese Acad Med Sci, Canc Hosp, Natl Canc Ctr, Dept Pancreatogastr Surg, Beijing, Peoples R China
[4] Peking Union Med Coll, Beijing, Peoples R China
[5] Nanchang Univ, State Key Lab Food Sci & Technol, Nanchang, Jiangxi, Peoples R China
[6] Hong Kong Baptist Univ, Dept Chem, State Key Lab Environm & Biol Anal, Hong Kong, Hong Kong, Peoples R China
基金
中国国家自然科学基金;
关键词
dioxins; human serum; large-volume injection; programmable-temperature vaporization; LARGE-VOLUME INJECTION; PCDD/F LEVELS; BLOOD; OPTIMIZATION; PCBS; POPULATIONS; MILK;
D O I
10.1002/jssc.201700465
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The determination of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans, and dioxin-like polychlorinated biphenyls in blood from a non-occupational population is essential for the investigation of adverse health effects from these pollutants. In this study, a sensitive method based on programmable-temperature vaporization with large-volume injection coupled with gas chromatography with high-resolution mass spectrometry was developed to determine these pollutants in 1-2 mL of human serum samples. Various key parameters of programmable-temperature vaporization injector, including vent temperature, vent time, vent flow, transfer temperature and transfer time were optimized by factorial design. The accuracy and precision as well as applicability were assessed by determining polychlorinated dibenzo-p-dioxins, polychlorinated dibenzofurans, and dioxin-like polychlorinated biphenyls in calibration standard solutions, standard reference materials and real human serum samples from non-occupational population. The method detection limits of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans, and dioxin-like polychlorinated biphenyls were 1.5-9.0 and 0.005-0.02 ng/kg wet weight, respectively. By comparing with typically splitless injection, the application of programmable-temperature vaporization injector could effectively lead to higher detectable rate of polychlorinated dibenzo-p-dioxins and polychlorinated dibenzofurans, and dioxin-like polychlorinated biphenyls in 1-2 mL of human serum samples.
引用
收藏
页码:3453 / 3461
页数:9
相关论文
共 31 条
[1]  
[Anonymous], 1994, ORGANOHALOGEN COMP
[2]   Optimisation of the GC-MS conditions for the determination of the 15 EU foodstuff priority pollycyclic aromatic hydrocarbons [J].
Bordajandi, Luisa R. ;
Dabrio, Marta ;
Ulberth, Franz ;
Emons, Hendrik .
JOURNAL OF SEPARATION SCIENCE, 2008, 31 (10) :1769-1778
[3]   Profile of PCDD/F levels in serum of general Taiwanese between different gender, age and smoking status [J].
Chen, HL ;
Liao, PC ;
Su, HJ ;
Guo, YL ;
Chen, CH ;
Lee, CC .
SCIENCE OF THE TOTAL ENVIRONMENT, 2005, 337 (1-3) :31-43
[4]   Blood levels of dioxins, furans, dioxin-like PCBs, and TEQs in general populations: A review, 1989-2010 [J].
Consonni, Dario ;
Sindaco, Raffaella ;
Bertazzi, Pier Alberto .
ENVIRONMENT INTERNATIONAL, 2012, 44 :151-162
[5]   PCDD/F levels in plasma of a Belgian population before and after the 1999 Belgian PCB/DIOXIN incident [J].
Debacker, Noemi ;
Sasse, Andre ;
van Wouwe, Nathalie ;
Goeyens, Leo ;
Sartor, Francis ;
van Oyen, Herman .
CHEMOSPHERE, 2007, 67 (09) :S217-S223
[6]   Chlorinated dibenzodioxins and dibenzofurans (PCDD/F) in blood and human milk of non occupationally exposed persons living in the vicinity of a municipal waste incinerator [J].
Deml, E ;
Mangelsdorf, I ;
Greim, H .
CHEMOSPHERE, 1996, 33 (10) :1941-1950
[7]   Levels of PCDD/PCDF in blood fat as indices of the PCDD/PCDF body burden in humans [J].
Ewers, U ;
Wittsiepe, J ;
Schrey, P ;
Selenka, F .
TOXICOLOGY LETTERS, 1996, 88 (1-3) :327-334
[8]   Spatial and temporal trends of the Stockholm Convention POPs in mothers' milk - a global review [J].
Fang, Johan ;
Nyberg, Elisabeth ;
Winnberg, Ulrika ;
Bignert, Anders ;
Bergman, Ake .
ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2015, 22 (12) :8989-9041
[9]  
Godula M, 2001, J SEP SCI, V24, P355, DOI 10.1002/1615-9314(20010501)24:5<355::AID-JSSC355>3.0.CO
[10]  
2-