Reduced Tear Meniscus Dynamics in Dry Eye Patients With Aqueous Tear Deficiency

被引:44
作者
Yuan, Yimin [1 ]
Wang, Jianhua [1 ]
Chen, Qi [1 ,2 ]
Tao, Aizhu [1 ,2 ]
Shen, Meixiao [1 ]
Abou Shousha, Mohamed
机构
[1] Univ Miami, Miller Sch Med, Bascom Palmer Eye Inst, Miami, FL 33136 USA
[2] Wenzhou Med Coll, Sch Ophthalmol & Optometry, Wenzhou, Peoples R China
基金
美国国家卫生研究院;
关键词
OCULAR SURFACE; ARTIFICIAL TEARS; BLINK RATE; PREVALENCE; HEIGHT; DIAGNOSIS; INSTILLATION; POPULATION; PARAMETERS; THICKNESS;
D O I
10.1016/j.ajo.2010.01.004
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE: To measure the tear meniscus dynamics in aqueous tear deficiency dry eye patients using optical coherence tomography. DESIGN: Clinical research study of a laboratory technique. METHODS: Twenty-five aqueous tear deficiency dry eye patients and 30 healthy subjects were recruited. Upper and lower tear menisci of 1 randomly selected eye of each participant were imaged during normal and delayed blinking using optical coherence tomography. Measured parameters included upper tear meniscus height and volume, lower tear meniscus height and volume, the blink outcome defined as the meniscus volume change during blink action, and open eye outcome defined as the meniscus volume change during the open eye period. RESULTS: During normal blinking, both tear meniscus height and volume before blink in dry eye patients were significantly smaller than those in healthy subjects, except for the upper tear meniscus volume. During normal blinking, the blink outcome and open eye outcome of lower tear meniscus were significantly smaller in dry eye patients compared with healthy subjects. During delayed blinking, the upper and lower tear menisci heights and volumes significantly increased in both groups. However, dry eye patients had smaller increases than healthy subjects. During delayed blinking, the open eye outcomes of upper and lower tear menisci were smaller in dry eye patients than healthy subjects. CONCLUSIONS: Dry eye patients seem to have reduced tear meniscus dynamics during normal blinking and smaller increases of meniscus volume during delayed blinking. Analysis of tear meniscus dynamics may provide more insight in the altered tear system in dry eye patients. (Am J Ophthalmol 2010;149:932-938. (C) 2010 by Elsevier Inc. All rights reserved.)
引用
收藏
页码:932 / 938
页数:7
相关论文
共 36 条
[21]   Effect of Blinking on Tear Volume After Instillation of Midviscosity Artificial Tears [J].
Palakuru, Jayachandra R. ;
Wang, Jianhua ;
Aquavella, James V. .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2008, 146 (06) :920-924
[22]   Evaluation of subjective assessments and objective diagnostic tests for diagnosing tear-film disorders known to cause ocular irritation [J].
Pflugfelder, SC ;
Tseng, SCG ;
Sanabria, O ;
Kell, H ;
Garcia, CG ;
Felix, C ;
Feuer, W ;
Reis, BL .
CORNEA, 1998, 17 (01) :38-56
[23]   Gravity, blink rate, and lacrimal drainage capacity [J].
Sahlin, S ;
Chen, EP .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1997, 124 (06) :758-764
[24]  
Sahlin Sven, 1998, Orbit, V17, P155, DOI 10.1076/orbi.17.3.155.2757
[25]   Tear meniscus evaluation by optical coherence tomography [J].
Savini, G ;
Barboni, P ;
Zanini, M .
OPHTHALMIC SURGERY LASERS & IMAGING, 2006, 37 (02) :112-118
[26]   Prevalence of dry eye syndrome among US women [J].
Schaumberg, DA ;
Sullivan, DA ;
Buring, JE ;
Dana, MR .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 2003, 136 (02) :318-326
[27]   Relation between signs and symptoms of dry eye in the elderly - A population-based perspective [J].
Schein, OD ;
Tielsch, JM ;
Munoz, B ;
BandeenRoche, K ;
West, S .
OPHTHALMOLOGY, 1997, 104 (09) :1395-1401
[28]   Prevalence of dry eye among the elderly [J].
Schein, OD ;
Munoz, B ;
Tielsch, JM ;
BandeenRoche, K ;
West, S .
AMERICAN JOURNAL OF OPHTHALMOLOGY, 1997, 124 (06) :723-728
[29]   Upper and Lower Tear Menisci in the Diagnosis of Dry Eye [J].
Shen, Meixiao ;
Li, Jianhua ;
Wang, Jianhua ;
Ma, Huixiang ;
Cai, Chunyan ;
Tao, Aizhu ;
Yuan, Yimin ;
Lu, Fan .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2009, 50 (06) :2722-2726
[30]  
TSUBOTA K, 1992, INVEST OPHTH VIS SCI, V33, P2942