A unified interaction equation for strength and global stability of solid and hollow concrete-filled steel tube columns under room and elevated temperatures

被引:16
作者
Yu, Min [1 ]
Xu, Haoming [1 ]
Ye, Jianqiao [1 ,2 ]
Chi, Yin [1 ]
机构
[1] Wuhan Univ, Sch Civil Engn, Wuhan 430072, Hubei, Peoples R China
[2] Univ Lancaster, Dept Engn, Lancaster LA1 4YR, England
基金
中国国家自然科学基金;
关键词
Concrete-filled steel tube (CFST); Unified interaction formula; Combined load; Average temperature; Fire resistance; FIRE RESISTANCE; TUBULAR COLUMNS; RHS COLUMNS; BEHAVIOR; MODEL;
D O I
10.1016/j.jcsr.2018.05.026
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
On the basis of plastic limit analysis, this paper proposes a novel, simple and unified interaction equation (N-M) for Concrete-filled Steel Tube (CFST) columns subjected to combined compression and bending. A unique feature of the new N-M equation is that the single equation is valid for a range of columns that can be solid, hollow, circular, polygonal, short or long. The single equation can also apply to columns under both room and elevated temperatures. Validations against independent laboratory test, analytical and numerical results are carried out to assess the accuracy and applicability of the equation. The new equation agrees well with most of the results used in the comparisons. It can be concluded that the simple and unified equation can be used in practical design with sufficient accuracy. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:304 / 313
页数:10
相关论文
共 55 条
[1]  
[Anonymous], 2004, 1994112004 EN BRIT S
[2]  
[Anonymous], 2014, GB 50936-2014
[3]  
[Anonymous], 1976, CONCRETE FILLED STEE
[4]  
British Standards Institution, 2005, 1994122005 EN BRIT S
[5]  
Cai S, 1985, J BUILD STRUCT, V4, P32, DOI [10.14006/j.jzjgxb.1985.04.004.html, DOI 10.14006/J.JZJGXB.1985.04.004.HTML]
[6]  
Cai S.H., 1990, Journal of Building Structures, V11, P1
[7]  
Chen W.F., 1976, PLANE BEHAV DESIGN, V1
[8]   Fire Resistance of Concrete Filled Square Steel Tube Columns Subjected to Eccentric Axial Load [J].
Chung, Kyungsoo ;
Park, Suhee ;
Choi, Sungmo .
INTERNATIONAL JOURNAL OF STEEL STRUCTURES, 2009, 9 (01) :69-76
[9]   Fire design method for bar-reinforced circular and elliptical concrete filled tubular columns [J].
Espinos, Ana ;
Romero, Manuel L. ;
Hospitaler, Antonio .
ENGINEERING STRUCTURES, 2013, 56 :384-395
[10]   Simple calculation model for evaluating the fire resistance of unreinforced concrete filled tubular columns [J].
Espinos, Ana ;
Romero, Manuel L. ;
Hospitaler, Antonio .
ENGINEERING STRUCTURES, 2012, 42 :231-244