Numerical evaluation of ultrasonic pulse-echo subwavelength defect detection

被引:0
|
作者
Yin, XT [1 ]
Morris, SA [1 ]
O'Brien, WD [1 ]
机构
[1] Univ Illinois, Dept Elect & Comp Engn, Bioacoust Res Lab, Urbana, IL 61801 USA
关键词
D O I
10.1109/ULTSYM.2002.1193504
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
The ultrasonic pulse-echo Backscattered Amplitude Integral (BAI)-mode imaging technique [UFTC Trans, 45:30, 1998] has been developed to detect small channel defects in flexible food package seals. This technique detects 38-mum-diameter channels reliably and 6-mum-diameter channels occasionally using a 17.3-MHz; focused transducer in water (20degreesC, lambda approximate to 86 mum, total sample thickness 220 mum). However, interaction between ultrasound and sample microstructure - the underlying detection mechanism is poorly understood. Experimental evidence showed that the subwavelength channel was fused inside the two binding trilaminate plastic package films. Each trilaminate film had three sublayers. Package sample impedance profiles along the ultrasound beam axis were examined. Although identical in nominal impedance properties before sealing, the two binding films showed an asymmetric impedance profile after sealing. A generalized impedance profile model was proposed. The defect detection behavior of the echo signal was investigated by solving the 2D linear acoustic wave equations in fluid with finite-difference time-domain method and the perfectly matched layer absorbing boundary. The normalized correlation coefficients between the simulated and the measured RF echo waveforms were greater than 95% for this generalized model.
引用
收藏
页码:729 / 732
页数:4
相关论文
共 50 条
  • [21] A calibration methodology of ultrasonic transducers: Evaluation of spatial propagation characteristics of pulse-echo
    Yoshida, Taiki
    Wada, Sanehiro
    Furuichi, Noriyuki
    MEASUREMENT, 2023, 214
  • [22] A SIMULATION-MODEL FOR ULTRASONIC PULSE-ECHO SYSTEMS
    UEDA, M
    MURATA, H
    ULTRASONICS, 1981, 19 (05) : 230 - 234
  • [23] Performance Evaluation of Neural Network Based Pulse-Echo Weld Defect Classifiers
    Seyedtabaii, S.
    MEASUREMENT SCIENCE REVIEW, 2012, 12 (05): : 168 - 174
  • [24] IMPROVEMENT IN PULSE-ECHO TECHNIQUE FOR ULTRASONIC ATTENUATION MEASUREMENTS
    TRIPATHI, RC
    GUPTA, AK
    VERMA, GS
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1973, 53 (04): : 1102 - 1106
  • [25] Ferroelectret Ultrasonic Transducers for Pulse-Echo Water Immersion
    Quirce, Julio
    Svilainis, Linas
    Camacho, Jorge
    Gomez Alvarez-Arenas, Tomas
    APPLIED SCIENCES-BASEL, 2020, 10 (24): : 1 - 14
  • [26] ULTRASONIC TRANSMISSION TOMOGRAPHY AND PULSE-ECHO IMAGING OF THE BREAST
    KOCH, R
    WHITING, JF
    PRICE, DC
    MCCAFFREY, JF
    ULTRASONIC IMAGING, 1982, 4 (02) : 188 - 189
  • [27] DUAL-FREQUENCY ULTRASONIC PULSE-ECHO TESTING
    GERICKE, OR
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1964, 36 (02): : 313 - &
  • [28] ULTRASONIC PULSE-ECHO TECHNIQUE AS APPLIED TO ADHESION TESTING
    TATTERSALL, HG
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1973, 6 (07) : 819 - 832
  • [29] SIMPLE CHOPPING CIRCUIT FOR ULTRASONIC PULSE-ECHO SYSTEM
    MATHUR, SS
    BAHUGUNA, RD
    AMERICAN JOURNAL OF PHYSICS, 1977, 45 (06) : 588 - 588
  • [30] Efficient transmit beamforming in pulse-echo ultrasonic imaging
    Cincotti, G
    Cardone, G
    Gori, P
    Pappalardo, M
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 1999, 46 (06) : 1450 - 1458