A Count Rate-Dependent Method for Spectral Distortion Correction in Photon Counting CT

被引:7
|
作者
Dickmann, Jannis [1 ,2 ,3 ]
Maier, Joscha [1 ,4 ]
Sawall, Stefan [1 ,5 ]
Thuering, Thomas [6 ]
Gkoumas, Spyridon [6 ]
Broennimann, Christian [6 ]
Kachelriess, Marc [1 ,5 ]
机构
[1] German Canc Res Ctr, Div Xray Imaging & CT, Neuenheimer Feld 280, Heidelberg, Germany
[2] KTH Royal Inst Technol, Roslagstullsbacken 21, Stockholm, Sweden
[3] Tech Univ Darmstadt, Karolinenpl 4, Darmstadt, Germany
[4] Ruprecht Karls Univ Heidelberg, Dept Phys & Astron, Neuenheimer Feld 226, Heidelberg, Germany
[5] Ruprecht Karls Univ Heidelberg, Med Fac, Neuenheimer Feld 672, Heidelberg, Germany
[6] Dectris Ltd, Tafernweg 1, Baden, Switzerland
来源
MEDICAL IMAGING 2018: PHYSICS OF MEDICAL IMAGING | 2018年 / 10573卷
关键词
spectral CT; photon counting; material decomposition; distortion correction; MATERIAL DECOMPOSITION; DETECTOR; MODEL;
D O I
10.1117/12.2292194
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Rawdata-based material decomposition in spectral CT using photon-counting energy-selective detectors relies on a precise forward model that predicts a count-rate given intersection lengths for each material. This requires extensive system-specific measurements or calibration techniques. Existing calibrations either estimate a detected spectrum and are able to account for spectrally distorted assumptions or correct the predicted count rate using a correction function and can accommodate for count rate-dependent effects such as pulse pileup. We propose a calibration method that uses transmission measurements to optimize a correction function that, unlike existing methods, depends both on the photon energy and the count rate. It is thus able to correct for both kinds of distortions. In a simulated material decomposition into water and iodine, the error was reduced by 96% compared to the best performing reference method if only pulse pileup was present and reduced by 23% if additionally spectral distortions were taken into account. In phantom measurements using a Dectris SANTIS prototype detector, the proposed method allowed to reduce the error by 29% compared to the best performing reference method. Artifacts were below the noise level for the proposed method, while the reference methods either showed an offset in the water region or ring artifacts.
引用
收藏
页数:8
相关论文
共 50 条
  • [1] A neural network-based method for spectral distortion correction in photon counting x-ray CT
    Touch, Mengheng
    Clark, Darin P.
    Barber, William
    Badea, Cristian T.
    PHYSICS IN MEDICINE AND BIOLOGY, 2016, 61 (16) : 6132 - 6153
  • [2] A Spectral CT Method to Directly Estimate Basis Material Maps From Experimental Photon-Counting Data
    Schmidt, Taly Gilat
    Barber, Rina Foygel
    Sidky, Emil Y.
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (09) : 1808 - 1819
  • [3] Count rate performance of a silicon-strip detector for photon-counting spectral CT
    Liu, X.
    Gronberg, F.
    Sjolin, M.
    Karlsson, S.
    Danielsson, M.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2016, 827 : 102 - 106
  • [4] Image-based spectral distortion correction for photon-counting x-ray detectors
    Ding, Huanjun
    Molloi, Sabee
    MEDICAL PHYSICS, 2012, 39 (04) : 1864 - 1876
  • [5] Contrast mediums discrimination by spectral photon-counting CT imaging
    Kimura, K.
    Koike, A.
    Aoki, T.
    HARD X-RAY, GAMMA-RAY, AND NEUTRON DETECTOR PHYSICS XX, 2018, 10762
  • [6] Photon-counting CT: modeling and compensating of spectral distortion effects
    Cammin, Jochen
    Kappler, Steffen
    Weidinger, Thomas
    Taguchi, Katsuyuki
    MEDICAL IMAGING 2015: PHYSICS OF MEDICAL IMAGING, 2015, 9412
  • [7] Count rate correction for pulse pileup in CdZnTe photon counting detectors
    Kang, Yang
    Wu, Rui
    Li, Peizheng
    Li, Qingpei
    Yin, Ziang
    Wu, Sen
    Tan, Tingting
    Li, Yingrui
    Zha, Gangqiang
    MATERIALS SCIENCE IN SEMICONDUCTOR PROCESSING, 2024, 173
  • [8] Spectral Photon Counting CT: Imaging Algorithms and Performance Assessment
    Wang, Adam S.
    Pelc, Norbert J.
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2021, 5 (04) : 453 - 464
  • [9] Study for band artifact correction for photon counting detector CT
    Kojima, Shinichi
    Yokoi, Kazuma
    Yamakawa, Keisuke
    Takahashi, Isao
    MEDICAL IMAGING 2022: PHYSICS OF MEDICAL IMAGING, 2022, 12031
  • [10] Iterative clustering material decomposition aided by empirical spectral correction for photon counting detectors in micro-CT
    Luna, J. Carlos Rodriguez
    Das, Mini
    JOURNAL OF MEDICAL IMAGING, 2024, 11