SHCC-strengthened RC panels under near-field explosions

被引:26
作者
Das Adhikary, Satadru [1 ]
Chandra, Lado Riannevo [2 ]
Christian, Abraham [2 ]
Ong, Khim Chye Gary [2 ]
机构
[1] Indian Inst Technol ISM, Dept Civil Engn, Dhanbad 826004, Bihar, India
[2] Natl Univ Singapore, Dept Civil & Environm Engn, 1 Engn Dr 2, Singapore 117576, Singapore
关键词
SHCC; Blast testing; Blast retrofit; MMALE; FSI; Numerical simulation; ENGINEERED CEMENTITIOUS COMPOSITES; REINFORCED-CONCRETE SLABS; AIR BLAST; BEHAVIOR;
D O I
10.1016/j.conbuildmat.2018.06.199
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Recurrence of recent activities in terms of accidental and premeditated explosions around the world has drawn the attention of the engineering community to assess the vulnerability of existing infrastructure under blast loading and find suitable repair and retrofitting technologies. Thus, this study focuses on the application of strain-hardening cementitious composite (SHCC) as a strengthening material by evaluating the response of SHCC-strengthened reinforced concrete (RC) panels under near-field explosions (scaled distance around 0.58 m/kg(1/3)) by spherical trinitrotoluene (TNT) charges as till now no study was conducted in this area. In total 5 panels, 1 control panel and 4 strengthened panels were tested under the same blast loading conditions. Two retrofit schemes (i.e., 'distal surface only' and both 'blast-incident and distal surfaces') were employed to retrofit the panels with a layer of SHCC. It was observed that the SHCC-strengthened panels perform better as compared to the control panel. Multi Material Arbitrary Lagrangian Eulerian (MMALE) with fluid-structure interaction (FSI) and Load Blast Enhanced (LBE) methodology available in LS-DYNA program were used to validate the blast wave parameters. Finally, three dimensional nonlinear finite element (FE) models were developed to compare the blast responses of the control and strengthened RC panels. This study as a whole will provide a guideline to the researchers and practicing engineers to deal with the blast retrofitting of RC structures. (C) 2018 Elsevier Ltd. All rights reserved.
引用
收藏
页码:675 / 692
页数:18
相关论文
共 33 条
[1]  
Adhikary S.D., 2016, ENG STRUCT
[2]  
[Anonymous], 1993, CEB FIP MOD COD 1990
[3]  
[Anonymous], DTIC DOCUMENT
[4]  
[Anonymous], 2012, LS-DYNA Keyword User's Manual Volume I (Version 971 R6.0.0), VI
[5]  
Chandra L. R., 2015, 5 INT C DES AN PROT
[6]  
Comite Euro-International du Beton, 2010, CEB FIP MOD COD 2010, V1
[7]   Blast resistance and mitigation strategies of structures: present status and future trends [J].
Das Adhikary, Satadru ;
Dutta, Sekhar Chandra .
PROCEEDINGS OF THE INSTITUTION OF CIVIL ENGINEERS-STRUCTURES AND BUILDINGS, 2019, 172 (04) :249-266
[8]  
Kingery C.N., 1984, Airblast parameters from TNT spherical air burst and hemispherical surface burst
[9]  
Lawve D., 2003, ASME Int Mech Eng Cong, P15
[10]  
Li V.C., 1993, J STRUCTURAL MECH EA, V10, P37