共 7 条
Effective degradation of 2,4-dihydroxybenzophenone by zero-valent iron powder (Fe0)-activated persulfate in aqueous solution: Kinetic study, product identification and theoretical calculations
被引:81
|作者:
Zou, Mengting
[1
]
Qi, Yumeng
[1
]
Qu, Ruijuan
[1
]
Al-Basher, Gadah
[2
]
Pan, Xiaoxue
[1
]
Wang, Zunyao
[1
]
Huo, Zongli
[3
]
Zhu, Feng
[3
]
机构:
[1] Nanjing Univ, Sch Environm, State Key Lab Pollut Control & Resources Reuse, Nanjing 210023, Jiangsu, Peoples R China
[2] King Saud Univ, Coll Sci, Zool Dept, POB 2455, Riyadh 11451, Saudi Arabia
[3] Jiangsu Prov Ctr Dis Control & Prevent, 172 Jiangsu Rd, Nanjing 210009, Jiangsu, Peoples R China
基金:
中国国家自然科学基金;
关键词:
2,4-Dihydroxybenzophenone;
Fe-0-activated persulfate;
Kinetics;
Reaction pathways;
THERMALLY ACTIVATED PERSULFATE;
UV FILTERS;
PHENOLIC-COMPOUNDS;
OXIDATIVE-DEGRADATION;
ESTROGENIC ACTIVITY;
RADICAL GENERATION;
ENHANCED OXIDATION;
IN-VITRO;
PEROXYMONOSULFATE;
SULFATE;
D O I:
10.1016/j.scitotenv.2020.144743
中图分类号:
X [环境科学、安全科学];
学科分类号:
08 ;
0830 ;
摘要:
2,4-Dihydroxybenzophenone (BP-1), a typically known derivative of the benzophenone-type UV filter, has been frequently detected in aqueous environments and poses a potential risk to human health and the entire ecosystem. In this study, an effective advanced oxidation technique using zero-valent iron powder (Fe-0)-activated persulfate (PS) was used for the degradation of BP-1. The effects of several experimental parameters, including Fe0 dosages, PS dosages, pH, and common natural water constituents, were systematically investigated. The BP-1 degradation efficiency was enhanced by increasing the Fe-0 and PS dosages and decreasing the solution pH. The presence of different concentrations of humic acid (HA) could inhibit BP-1 removal, while the addition of various cations and anions had different effects on the degradation. Moreover, the degradation of BP-1 in five water matrices was also compared, and the removal rates followed the order of ultrapure water > tap water > secondary clarifier effluent > river water > synthetic water. Thirteen oxidation products were identified by liquid chromatography-time-of-flight-mass spectrometry (LC-TOF-MS) analysis, and five possible degradation pathways were proposed. The addition reactions initiated by HO center dot and SO4 center dot(-), as well as single-electron coupling reactions and ring-closing reactions, were further supported by density functional theory (DFT) calculations. Assessment of toxicity of intermediates of the oxidation of BP-1 suggested decreased toxicity from the parent contaminant. The present work illustrates that BP-1 could be efficiently degraded in the Fe-0/PS system, which may provide new insights into the removal of benzophenones in water and wastewater. (C) 2021 Elsevier B.V. All rights reserved.
引用
收藏
页数:12
相关论文