Characterization of a nanoflow sheath liquid interface and comparison to a sheath liquid and a sheathless porous-tip interface for CE-ESI-MS in positive and negative ionization

被引:45
作者
Hoecker, Oliver [1 ]
Montealegre, Cristina [1 ]
Neusuess, Christian [1 ]
机构
[1] Aalen Univ, Dept Chem, Beethovenstr 1, D-73430 Aalen, Germany
关键词
Capillary electrophoresis/electrophoresis; Mass spectrometry; Electrospray ionization; Interfacing; ELECTROPHORESIS-MASS-SPECTROMETRY; CAPILLARY-ZONE-ELECTROPHORESIS; FLOW NANOSPRAY INTERFACE; SENSITIVITY SAMPLE QUANTIFICATION; ELECTROSPRAY-IONIZATION; COMPLEX PROTEOMES; CHARGE-STATE; PEPTIDE; EFFICIENCY; EMITTER;
D O I
10.1007/s00216-018-1179-3
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
Coupling of capillary electrophoresis to electrospray mass spectrometry still remains challenging and a topic of research to find the best interface regarding sensitivity, robustness, and ease of use. Here, a nanoflow sheath liquid interface for CE-ESI-MS is presented and compared to both a standard triple-tube sheath liquid and a porous-tip sheathless interface for three groups of analytes. The nanoflow sheath liquid interface with a separation capillary inserted into a glass emitter was initially characterized to facilitate optimization and method development. Implementation of a shut-off valve, syringe pump, and inline filter enabled easy handling and fast analyses, repeatable both in positive and negative modes (intra-day RSD of 6.6 to 12.0%). The same setup was used for sheathless interfacing by exchanging the emitter and using a porous etched tip separation capillary. Both nanoflow interfaces showed similar performance. Average peak areas using the nanoflow sheath liquid interface were a factor of 38 for 6 organic acids in negative mode, 114 and 36 for the light and heavy chain of a monoclonal antibody, and 13 higher for peptides in positive mode compared to the triple-tube interface. This first direct comparison of the three most common interfaces exhibits a strong improvement in sensitivity to the same extent for both nanoflow interfaces, where sheath liquid interfaces offer full flexibility in method development.
引用
收藏
页码:5265 / 5275
页数:11
相关论文
共 53 条
[1]   Electrospray Ionization Mass Spectrometry: A Technique to Access the Information beyond the Molecular Weight of the Analyte [J].
Banerjee, Shibdas ;
Mazumdar, Shyamalava .
INTERNATIONAL JOURNAL OF ANALYTICAL CHEMISTRY, 2012, 2012
[2]   Capillary electrophoresis-electrospray ionization-mass spectrometry interfaces: Fundamental concepts and technical developments [J].
Bonvin, Gregoire ;
Schappler, Julie ;
Rudaz, Serge .
JOURNAL OF CHROMATOGRAPHY A, 2012, 1267 :17-31
[3]   Practical implications of some recent studies in electrospray ionization fundamentals [J].
Cech, NB ;
Enke, CG .
MASS SPECTROMETRY REVIEWS, 2001, 20 (06) :362-387
[4]   Strong cation exchange-reversed phase liquid chromatography-capillary zone electrophoresis-tandem mass spectrometry platform with high peak capacity for deep bottom-up proteomics [J].
Chen, Daoyang ;
Shen, Xiaojing ;
Sun, Liangliang .
ANALYTICA CHIMICA ACTA, 2018, 1012 :1-9
[5]   Tapered-Tip Capillary Electrophoresis Nano-Electrospray Ionization Mass Spectrometry for Ultrasensitive Proteomics: the Mouse Cortex [J].
Choi, Sam B. ;
Zamarbide, Marta ;
Manzini, M. Chiara ;
Nemes, Peter .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2017, 28 (04) :597-607
[6]   SOLVENT EFFECT ON ANALYTE CHARGE-STATE, SIGNAL INTENSITY, AND STABILITY IN NEGATIVE-ION ELECTROSPRAY MASS-SPECTROMETRY - IMPLICATIONS FOR THE MECHANISM OF NEGATIVE-ION FORMATION [J].
COLE, RB ;
HARRATA, AK .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1993, 4 (07) :546-556
[7]   Capillary Isoelectric Focusing-Mass Spectrometry Method for the Separation and Online Characterization of Intact Monoclonal Antibody Charge Variants [J].
Dai, Jun ;
Lamp, Jared ;
Xia, Qiangwei ;
Zhang, Yingru .
ANALYTICAL CHEMISTRY, 2018, 90 (03) :2246-2254
[8]  
Dovichi NJ, 2013, US, Patent No. [2013/ 0140180 A1, 20130140180]
[9]   Efficiency of nano-electrospray ionization [J].
El-Faramawy, A ;
Siu, KWM ;
Thomson, BA .
JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 2005, 16 (10) :1702-1707
[10]   Quantitative Proteomics Using Ultra low Flow Capillary Electrophoresis-Mass Spectrometry [J].
Faserl, Klaus ;
Kremser, Leopold ;
Mueller, Martin ;
Teis, David ;
Lindner, Herbert H. .
ANALYTICAL CHEMISTRY, 2015, 87 (09) :4633-4640