Temperature measurement of stored biomass using low-frequency acoustic waves and correlation signal processing techniques

被引:20
作者
Guo, Miao [1 ]
Yan, Yong [1 ,2 ]
Hu, Yonghui [1 ]
Lu, Gang [2 ]
Zhang, Jingqiong [2 ]
机构
[1] North China Elect Power Univ, Sch Control & Comp Engn, Beijing 102206, Peoples R China
[2] Univ Kent, Sch Engn & Digital Arts, Canterbury CT2 7NT, Kent, England
关键词
Biomass; Temperature measurement; Sound wave; Acoustic sensor; Linear chirp signal; Correlation; SOUND-TRANSMISSION; TOMOGRAPHY; GRAIN; AIR;
D O I
10.1016/j.fuel.2018.04.062
中图分类号
TE [石油、天然气工业]; TK [能源与动力工程];
学科分类号
0807 ; 0820 ;
摘要
As a substitute of traditional fossil fuels, biomass is widely used to generate electricity and heat. The temperature of stored biomass needs to be monitored continuously to prevent the biomass from self-ignition. This paper proposes a non-intrusive method for the temperature measurement of stored biomass based on acoustic sensing techniques. A characteristic factor is introduced to obtain the sound speed in free space from the measured time of flight of acoustic waves in stored biomass. After analysing the relationship between the defined characteristic factor and air temperature, an updating procedure on the characteristic factor is proposed to reduce the influence of air temperature. By measuring the sound speed in free space, air temperature is determined which is the same as biomass temperature. The proposed methodology is examined using a single path acoustic system which consists of a source and two sensors. A linear chirp signal with a duration of 0.1 s and frequencies of 200-500 Hz is generated and transmitted through stored biomass pellets. The time of flight of sound waves between the two acoustic sensors is measured through correlation signal processing. The relative error of measurement results using the proposed method is no more than 4.5% over the temperature range from 22 degrees C to 48.9 degrees C. Factors that affect the temperature measurement are investigated and quantified. The experimental results indicate that the proposed technique is effective for the temperature measurement of stored biomass with a maximum error of 1.5 degrees C under all test conditions.
引用
收藏
页码:89 / 98
页数:10
相关论文
共 35 条
[1]   Real-time temperature field measurement based on acoustic tomography [J].
Bao, Yong ;
Jia, Jiabin ;
Polydorides, Nick .
MEASUREMENT SCIENCE AND TECHNOLOGY, 2017, 28 (07)
[2]  
Blomqvist P, 2006, SP SWEDISH NATL TEST, V41, P15
[3]  
BOHN DA, 1988, J AUDIO ENG SOC, V36, P223
[4]   Experimental investigations into the flow characteristics of pneumatically conveyed biomass particles using an electrostatic sensor array [J].
Coombes, James Robert ;
Yan, Yong .
FUEL, 2015, 151 :11-20
[5]   Experimental study on underwater acoustic imaging of 2-D temperature distribution around hot springs on floor of Lake Qiezishan, China [J].
Fan, Wei ;
Chen, Ying ;
Pan, Huachen ;
Ye, Ying ;
Cai, Yong ;
Zhang, Zhujun .
EXPERIMENTAL THERMAL AND FLUID SCIENCE, 2010, 34 (08) :1334-1345
[6]   On-line particle sizing of pneumatically conveyed biomass particles using piezoelectric sensors [J].
Gao, Lingjun ;
Yan, Yong ;
Carter, Robert M. ;
Sun, Duo ;
Lee, Peter ;
Xu, Chuanlong .
FUEL, 2013, 113 :810-816
[7]   EQUATION FOR THE DETERMINATION OF THE DENSITY OF MOIST AIR (1981) [J].
GIACOMO, P .
METROLOGIA, 1982, 18 (01) :33-40
[8]  
Guo M., 2018, CHIN J SCI INSTRUM, V39, P76
[9]  
Hardy B., 1998, Third International Symposium on Humidity Moisture, P1
[10]   Studies of sound transmission in various types of stored grain for acoustic detection of insects [J].
Hickling, R ;
Wei, W ;
Hagstrum, DW .
APPLIED ACOUSTICS, 1997, 50 (04) :263-278