Vanillylmandelic and Homovanillic acid: Electroanalysis at non-modified and polymer-modified carbon-based electrodes

被引:38
作者
Baluchova, Simona [1 ]
Barek, Jiri [1 ]
Tome, Luciana I. N. [2 ]
Brett, Christopher M. A. [2 ]
Schwarzova-Peckova, Karolina [1 ]
机构
[1] Charles Univ Prague, Dept Analyt Chem, Fac Sci, UNESCO Lab Environm Electrochem, Albertov 6, Prague 12843 2, Czech Republic
[2] Univ Coimbra, Fac Sci & Technol, Dept Chem, Rua Larga, P-3004535 Coimbra, Portugal
关键词
Homovanillic acid; Vanillylmandelic acid; Boron-doped diamond; Modified glassy carbon electrode; Voltammetry; BORON-DOPED DIAMOND; HUMAN URINE SAMPLES; PERFORMANCE LIQUID-CHROMATOGRAPHY; COMPETITIVE ENZYME-IMMUNOASSAY; NEUROENDOCRINE TUMOR-MARKERS; CAPILLARY-ELECTROPHORESIS; CATECHOLAMINE METABOLITES; AMPEROMETRIC DETECTION; MASS-SPECTROMETRY; ASCORBIC-ACID;
D O I
10.1016/j.jelechem.2018.03.011
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical behaviour of two main catecholamine metabolites serving as diagnostic tumour biomarkers, homovanillic acid (HVA) and vanillylmandelic acid (VMA), on anodically oxidized boron doped diamond (BDD) electrodes, non-modified glassy carbon electrodes (GCE), and GCE modified by polymers, namely by Nafion (Nafion/GCE) and by poly(neutral red) (PNR/GCE), was investigated. The voltammetric responses of both biomarkers are strongly dependent on pH of the aqueous buffer solution and electrode material used. BDD electrodes exhibit more positive oxidation potentials and lower current densities for oxidation of both analytes, depending also on the surface termination. Concentration dependences were measured in 0.1 mol L-1 phosphate buffer pH 3.0, as optimal supporting electrolyte for differential pulse voltammetric determination. Achieved detection limits were 0.6, 0.9, 0.8, and 1.2 mu mol L-1 for HVA and 0.4, 1.5, 2.4, and 1.1 mu mol L-1 for VMA at BDD electrodes, non-modified GCE, Nafion/GCE, and PNR/GCE, respectively. The limits of quantification for both organic compounds on all tested electrode materials are sufficiently low for their determination in urine. Verification of the possibility of simultaneous voltammetric determination of the studied biomarkers in the mixture was also carried out.
引用
收藏
页码:22 / 32
页数:11
相关论文
共 91 条
  • [1] Development of a voltammetric technique for monitoring brain dopamine metabolism: compensation for interference caused by DOPAC electrogenerated during homovanillic acid detection
    Al Mulla, Ismael
    Lowry, John P.
    Serra, Pier Andrea
    O'Neill, Robert D.
    [J]. ANALYST, 2009, 134 (05) : 893 - 898
  • [2] Alemany G, 1996, BIOMED CHROMATOGR, V10, P144, DOI 10.1002/(SICI)1099-0801(199605)10:3<144::AID-BMC570>3.3.CO
  • [3] 2-J
  • [4] Selective and simultaneous determination of total chlorogenic acids, vanillin and caffeine in foods and beverages by adsorptive stripping voltammetry using a cathodically pretreated boron-doped diamond electrode
    Alpar, Nurcan
    Yardim, Yavuz
    Senturk, Zuhre
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2018, 257 : 398 - 408
  • [5] Liquid chromatography in the analysis of neurotransmitters and alkaloids
    Baranowska, I
    Zydron, M
    [J]. JOURNAL OF CHROMATOGRAPHIC SCIENCE, 2002, 40 (04) : 224 - 228
  • [6] Urinary homovanillic and vanillylmandelic acid in the diagnosis of neuroblastoma: Report from the Italian Cooperative Group for Neuroblastoma
    Barco, Sebastian
    Gennai, Iulian
    Reggiardo, Giorgio
    Galleni, Barbara
    Barbagallo, Laura
    Maffia, Angelo
    Viscardi, Elisabetta
    De Leonardis, Francesco
    Cecinati, Valerio
    Sorrentino, Stefania
    Garaventa, Alberto
    Conte, Massimo
    Cangemi, Giuliana
    [J]. CLINICAL BIOCHEMISTRY, 2014, 47 (09) : 848 - 852
  • [7] Electrooxidation of chlorophenols at a glassy carbon electrode in a pH 11 buffer
    Berrios, C.
    Arce, R.
    Rezende, M. C.
    Ureta-Zanartu, M. S.
    Gutierrez, C.
    [J]. ELECTROCHIMICA ACTA, 2008, 53 (06) : 2768 - 2775
  • [8] Electrochemical behavior of catecholamines and related compounds at in situ surfactant modified carbon paste electrodes
    Blanco-Lopez, M. Carmen
    Lobo-Castanon, M. Jesus
    Ordieres, Arturo J. Miranda
    Tunon-Blanco, Paulino
    [J]. ELECTROANALYSIS, 2007, 19 (2-3) : 207 - 213
  • [9] Voltammetric sensor for vanillylmandelic acid based on molecularly imprinted polymer-modified electrodes
    Blanco-López, MC
    Lobo-Castañón, MJ
    Miranda-Ordieres, AJ
    Tuñón-Blanco, P
    [J]. BIOSENSORS & BIOELECTRONICS, 2003, 18 (04) : 353 - 362
  • [10] Assessments of the Effect of Increasingly Severe Cathodic Pretreatments on the Electrochemical Activity of Polycrystalline Boron-Doped Diamond Electrodes
    Brocenschi, Ricardo F.
    Hammer, Peter
    Deslouis, Claude
    Rocha-Filho, Romeu C.
    [J]. ANALYTICAL CHEMISTRY, 2016, 88 (10) : 5363 - 5368