Trend of soil temperature during pipeline leakage of high-pressure natural gas: Experimental and numerical study

被引:35
作者
Zhou, Zhaoming [1 ]
Zhang, Jia [1 ]
Huang, Xuesong [2 ]
Zhang, Jie [1 ]
Guo, Xishui [2 ]
机构
[1] Southwest Petr Univ, Sch Mechatron Engn, Chengdu 610500, Sichuan, Peoples R China
[2] Petr Engn Technol Res Inst Sinopec Zhongyuan Oilf, Puyang 457000, Henan, Peoples R China
基金
中国国家自然科学基金;
关键词
Gas leakage experiment; Natural gas buried pipeline; Distributed optical fiber; Temperature detection; Leakage detection; Numerical analysis; SIGNAL; LOCATION; SENSOR;
D O I
10.1016/j.measurement.2019.107440
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The key to buried gas pipeline leakage detection using a distributed optical fiber is to detect temperature changes. However, the trend of temperature change caused by natural gas leakage lacks tests and verification. Optical cable laying on site is not standard. In this work, combined with the Peng-Robinson (PR) real gas state equation and fiber Raman scattering principle, the trend of soil temperature around a leakage hole was systematically studied. The simulation results show that the higher the pressure of pipeline, leakage hole and soil porosity, the faster the rate of temperature change is monitored, the greater the temperature change at leakage hole. Temperature change can be clearly detected within 100 mm from the leak hole. On this basis, a field test was conducted for a buried high-pressure gas pipeline leakage. The test used the array of point temperature sensor and fiber to collect the change of soil temperature. The test results show that the soil temperature field at the leakage hole changed the most. The temperature change was detected within 100 mm away from the leakage hole. The test and simulation results are basically consistent. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:14
相关论文
共 39 条
  • [1] Agrawal A., 2017, RECENT TRENDS COMPUT, DOI [10.1007/978-3-319-55438-9, DOI 10.1007/978-3-319-55438-9]
  • [2] Ai G., 2015, J PRESSURE VESSEL, V32, P1, DOI DOI 10.3969/J.ISSN.1001-4837.2015.09.001
  • [3] [艾刚 Ai Gang], 2016, [机械工程学报, Journal of Mechanical Engineering], V52, P97
  • [4] Feasibility of Locating Leakages in Sewage Pressure Pipes Using the Distributed Temperature Sensing Technology
    Apperl, Benjamin
    Pressl, Alexander
    Schulz, Karsten
    [J]. WATER AIR AND SOIL POLLUTION, 2017, 228 (02)
  • [5] Localization of CO2 leakage from transportation pipelines through low frequency acoustic emission detection
    Cui, Xiwang
    Yan, Yong
    Ma, Yifan
    Ma, Lin
    Han, Xiaojuan
    [J]. SENSORS AND ACTUATORS A-PHYSICAL, 2016, 237 : 107 - 118
  • [6] Experimental study on acoustic propagation-characteristics-based leak location method for natural gas pipelines
    Cui-wei, Liu
    Yu-xing, Li
    Jun-tao, Fu
    Guang-xiao, Liu
    [J]. PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2015, 96 : 43 - 60
  • [7] A Fiber-Optic System for the Quasi-Distributed Detection of Liquids
    Donlagic, Denis
    Preloznik, Borut
    [J]. IEEE PHOTONICS TECHNOLOGY LETTERS, 2015, 27 (18) : 1895 - 1898
  • [8] A metrological comparison of Raman-distributed temperature sensors
    Failleau, G.
    Beaumont, O.
    Razouk, R.
    Delepine-Lesoille, S.
    Landolt, M.
    Courthial, B.
    Henault, J. M.
    Martinot, F.
    Bertrand, J.
    Hay, B.
    [J]. MEASUREMENT, 2018, 116 : 18 - 24
  • [9] Feng X., 2016, Journal of Water Resources and Architectura-l Engineering, V14, P1
  • [10] GE N, 2008, J T TECHNOL, V21, P2005, DOI DOI 10.3969/J.ISSN.1004-1699.2008.12.011