Novel ultrahigh resolution data acquisition and image reconstruction for multi-detector row CT

被引:78
作者
Flohr, T. G.
Stierstorfer, K.
Suess, C.
Primak, A. N.
McCollough, C. H.
机构
[1] Siemens Med Solut, Computed Tomog CTE PA, D-91301 Forchheim, Germany
[2] Univ Tubingen, Dept Diagnost Radiol, Tubingen, Germany
[3] Mayo Clin, Coll Med, Dept Radiol, Rochester, MN USA
关键词
multi-detector row CT; CT image quality evaluation; high resolution CT;
D O I
10.1118/1.2722872
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
We present and evaluate a special ultrahigh resolution mode providing considerably enhanced spatial resolution both in the scan plane and in the z-axis direction for a routine medical multidetector row computed tomography (CT) system. Data acquisition is performed by using a flying focal spot both in the scan plane and in the z-axis direction in combination with tantalum grids that are inserted in front of the multi-row detector to reduce the aperture of the detector elements both in-plane and in the z-axis direction. The dose utilization of the system for standard applications is not affected, since the grids are moved into place only when needed and are removed for standard scanning. By means of this technique, image slices with a nominal section width of 0.4 mm (measured full width at half maximum = 0.45 mm) can be reconstructed in spiral mode on a CT system with a detector configuration of 32 x 0.6 mm. The measured 2% value of the in-plane modulation transfer function (MTF) is 20.4 lp/cm, the measured 2% value of the longitudinal (z axis) MTF is 21.5 lp/cm. In a resolution phantom with metal line pair test patterns, spatial resolution of 20 lp/cm can be demonstrated both in the scan plane and along the z axis. This corresponds to an object size of 0.25 mm that can be resolved. The new mode is intended for ultrahigh resolution bone imaging, in particular for wrists, joints, and inner ear studies, where a higher level of image noise due to the reduced aperture is an acceptable trade-off for the clinical benefit brought about by the improved spatial resolution. (c) 2007 American Association of Physicists in Medicine.
引用
收藏
页码:1712 / 1723
页数:12
相关论文
共 10 条
[1]   Image reconstruction and image quality evaluation for a 16-slice CT scanner [J].
Flohr, T ;
Stierstorfer, K ;
Bruder, H ;
Simon, J ;
Polacin, A ;
Schaller, S .
MEDICAL PHYSICS, 2003, 30 (05) :832-845
[2]   Multi-detector row CT systems and image-reconstruction techniques [J].
Flohr, TG ;
Schaller, S ;
Stierstorfer, K ;
Bruder, H ;
Ohnesorge, BM ;
Schoepf, UJ .
RADIOLOGY, 2005, 235 (03) :756-773
[3]   Image reconstruction and image quality evaluation for a 64-slice CT scanner with z-flying focal spot [J].
Flohr, TG ;
Stierstorfer, K ;
Ulzheimer, S ;
Bruder, H ;
Primak, AN ;
McCollough, CH .
MEDICAL PHYSICS, 2005, 32 (08) :2536-2547
[4]   Spiral interpolation algorithms for multislice spiral CT - Part II: Measurement and evaluation of slice sensitivity profiles and noise at a clinical multislice system [J].
Fuchs, T ;
Krause, J ;
Schaller, S ;
Flohr, T ;
Kalender, WA .
IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (09) :835-847
[5]   Ultra-high resolution flat-panel volume CT: fundamental principles, design architecture, and system characterization [J].
Gupta, Rajiv ;
Grasruck, Michael ;
Suess, Christoph ;
Bartling, Soenke H. ;
Schmidt, Bernhard ;
Stierstorfer, Karl ;
Popescu, Stefan ;
Brady, Tom ;
Flohr, Thomas .
EUROPEAN RADIOLOGY, 2006, 16 (06) :1191-1205
[6]   Four multidetector-row helical CT: Image quality and volume coverage speed [J].
Hu, H ;
He, HD ;
Foley, WD ;
Fox, SH .
RADIOLOGY, 2000, 215 (01) :55-62
[7]   Multi-slice helical CT: Scan and reconstruction [J].
Hu, H .
MEDICAL PHYSICS, 1999, 26 (01) :5-18
[8]  
KNOLLMANN F, 2003, CIRCULATION, V107
[9]   Dual-slice spiral versus single-slice spiral scanning: Comparison of the physical performance of two computed tomography scanners [J].
Liang, Y ;
Kruger, RA .
MEDICAL PHYSICS, 1996, 23 (02) :205-220
[10]   Flat panel computed tomography of human ex vivo heart and bone specimens: initial experience [J].
Nikolaou, K ;
Flohr, T ;
Stierstorfer, K ;
Becker, CR ;
Reiser, MF .
EUROPEAN RADIOLOGY, 2005, 15 (02) :329-333