In-vivo cell and tissue monitoring with active implants

被引:0
作者
Clauss, Johannes F. [1 ]
Wirths, Walter [1 ,2 ]
Roos, Michael [1 ]
Woehrle, Budi [1 ]
Brischwein, Martin [1 ]
Wolf, Bernhard [1 ]
机构
[1] Tech Univ Munich, Heinz Nixdorf Lehrstuhl Med Elekt, D-80290 Munich, Germany
[2] Erwin Quarder Syst Tech GmbH, Lossburg, Germany
来源
2015 37TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC) | 2015年
关键词
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Active implant systems are becoming increasingly important in modern medicine. We describe the development of an implantable system for the monitoring of dissolved oxygen. Tissue oxygen saturation plays a leading role in many pathophysiological processes in the human body such as the growth of malignant tumors or the viability of transplanted organs. The implant allows monitoring the tissue oxygenation in vivo with a wireless interface to an external device. An improved self-calibration technique is described to minimize sensor drift with electrochemical sensors in vivo for a better long term stability of the implant system. The sensor was coated with a hydrogel membrane to avoid convection artifacts during calibration procedure.
引用
收藏
页码:7087 / 7090
页数:4
相关论文
共 15 条
  • [1] Concept for a gas-cell-driven drug delivery system for therapeutic applications
    Becker, S.
    Xu, T.
    Ilchmann, F.
    Eisler, J.
    Wolf, B.
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2011, 225 (H12) : 1196 - 1201
  • [2] Becker S., 2010, Biomedizinische Technik, V55, P4, DOI 10.1515/BMT.2010.329
  • [3] Becker S., 2010, BMT S1, V55, P44
  • [4] Becker S., 2011, P DTSCH BIOS FOR 201, P30
  • [5] Clauss J., 2012, BIOELEKTRONISCHE DIA, P237
  • [6] Self calibration of a planar dissolved oxygen sensor
    Eminaga, Yazay
    Brischwein, Martin
    Wiest, Joachim
    Clauss, Johannes
    Becker, Sven
    Wolf, Bernhard
    [J]. SENSORS AND ACTUATORS B-CHEMICAL, 2013, 177 : 785 - 791
  • [7] Relevance of tumor microenvironment for progression, therapy and drug development
    Henning, T
    Kraus, M
    Brischwein, M
    Otto, AM
    Wolf, B
    [J]. ANTI-CANCER DRUGS, 2004, 15 (01) : 7 - 14
  • [8] Analysis of drug action on tumor cell metabolism using electronic sensor chips
    Otto, AM
    Brischwein, M
    Motrescu, E
    Wolf, B
    [J]. ARCHIV DER PHARMAZIE, 2004, 337 (12) : 682 - 686
  • [9] The role of hypoxia-induced factors in tumor progression
    Vaupel, P
    [J]. ONCOLOGIST, 2004, 9 : 10 - 17
  • [10] White H S, 2001, ELECTROCHEMICAL METH