Comparative evaluation of the intermediate systems employed in two-stage refrigeration cycles driven by compound compressors

被引:19
作者
Cabello, R. [1 ]
Torrella, E. [2 ]
Llopis, R. [1 ]
Sanchez, D. [1 ]
机构
[1] Jaume I Univ, Dep Mech Engn & Construct, E-12071 Castellon de La Plana, Spain
[2] Univ Politecn Valencia, Dep Appl Thermodynam, E-46022 Valencia, Spain
关键词
Two-stage system; Intermediate injection; Subcooler; Compound compressor; R404A; OPTIMIZATION;
D O I
10.1016/j.energy.2009.11.009
中图分类号
O414.1 [热力学];
学科分类号
摘要
This work presents an experimental evaluation, from an energy analysis point of view, for two of the most used inter-stage systems in two-stage vapour compression cycles driven by compound compressors: the direct liquid injection and subcooler systems. The evaluation, considers the two-stage cycle with no intermediate systems as reference cycle and was performed on a plant, driven by a compound compressor using the refrigerant R404A for an evaporating temperature range of -36 to -20 degrees C and for a condensing temperature range of 30-47 degrees C. The analysis of the results shows that the inter-stage systems determine the performance of the energy parameters, which are discussed in the paper. The configuration yielding the best results was the two-stage compression cycle with subcooler, since the cooling capacity and COP values for this configuration were the highest. Conversely, the two-stage compression cycle working with direct liquid injection showed lower performance from an energy point of view, though this configuration allows a substantial reduction of the discharge temperature. (C) 2009 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1274 / 1280
页数:7
相关论文
共 12 条
[1]   Optimization of two-stage transcritical carbon dioxide heat pump cycles [J].
Agrawal, Neeraj ;
Bhattacharyya, Souvik ;
Sarkar, J. .
INTERNATIONAL JOURNAL OF THERMAL SCIENCES, 2007, 46 (02) :180-187
[2]   Studies on a two-stage transcritical carbon dioxide heat pump cycle with flash intercooling [J].
Agrawal, Neeraj ;
Bhattacharyya, Souvik .
APPLIED THERMAL ENGINEERING, 2007, 27 (2-3) :299-305
[3]  
[Anonymous], THESIS ECOLE POLYTEC
[4]  
[Anonymous], HVAC RES
[5]  
[Anonymous], THESIS U MARYLAND CO
[6]  
[Anonymous], INT J REFRIGERATION
[7]   Analysis of the variation mechanism in the main energetic parameters in a single-stage vapour compression plant [J].
Cabello, R. ;
Navarro-Esbri, J. ;
Llopis, R. ;
Torrella, E. .
APPLIED THERMAL ENGINEERING, 2007, 27 (01) :167-176
[8]   Two-stage transcritical carbon dioxide cycle optimisation: A theoretical and experimental analysis [J].
Cavallini, A ;
Cecchinato, L ;
Corradi, M ;
Fornasieri, E ;
Zilio, C .
INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2005, 28 (08) :1274-1283
[9]  
Gosney W.B., 1982, PRINCIPLES REFRIGERA
[10]   Experimental Energetic Analysis of the Subcooler System in a Two-Stage Refrigeration Facility Driven by a Compound Compressor [J].
Torrella, Enrique ;
Llopis, Rodrigo ;
Cabello, Ramon ;
Sanchez, Daniel .
HVAC&R RESEARCH, 2009, 15 (03) :583-596