Mechanical properties of the abdominal wall and biomaterials utilized for hernia repair

被引:170
作者
Deeken, Corey R. [1 ]
Lake, Spencer P. [2 ]
机构
[1] Covalent Bio LLC, St Louis, MO USA
[2] Washington Univ, Dept Mech Engn & Mat Sci, St Louis, MO USA
关键词
Abdominal wall; Anisotropy; Biomaterials; Hernia repair; Mechanics; Mesh; PORCINE MODEL; IN-VIVO; POLYPROPYLENE MESH; INCISIONAL HERNIA; BIOMECHANICAL PROPERTIES; MORPHOLOGIC VARIATIONS; COMPOSITE MESH; FOLLOW-UP; PORE-SIZE; BEHAVIOR;
D O I
10.1016/j.jmbbm.2017.05.008
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Abdominal wall hernias are one of the most common and long-standing surgical applications for biomaterials engineering. Yet, despite over 50 years of standard use of hernia repair materials, revision surgery is still required in nearly one third of patients due to hernia recurrence. To date, hernia mesh designs have focused on maximizing tensile strength to prevent structural failure of the implant. However, most recurrences occur at the biomaterial-tissue interface. There is a fundamental gap in understanding the degree to which a mechanical mismatch between hernia repair materials and host tissue contributes to failure at this interface. This review summarizes the current literature related to the anatomy and mechanics of both human and animal abdominal wall tissues, as well as the mechanical properties of many commonly-utilized hernia repair materials. The studies reviewed here reported greater compliance of the linea alba, larger strains for the intact abdominal wall, and greater stiffness for the rectus sheath and umbilical fascia when the tissues were loaded in the longitudinal direction compared to transverse. Additionally, greater stresses were observed in the linea alba when loaded in the transverse direction compared to longitudinal. Given these trends, a few recommendations can be made regarding orientation of mesh. The most compliant axis of the biomaterial should be oriented in the cranio-caudal (longitudinal) direction, and the strongest axis of the biomaterial should be oriented in the medial-lateral (transverse) direction. The human abdominal wall is also anisotropic, with anisotropy ratios as high as 8-9 reported for the human linea alba. Current biomaterial designs exhibit anisotropy ratios in the range of 1-3, and it is unclear whether an ideal ratio exists for optimal match between mesh and tissue. This is likely dependent on implantation location as the linea alba, rectus sheath, and other tissues of the abdominal wall exhibit different characteristics. Given the number of unknowns yet to be addressed by studies of the human abdominal wall, it is unlikely that any single biomaterial design currently encompasses all of the ideal features identified. More data on the mechanical properties of the abdominal wall will be needed to establish a full set of guidelines for ideal mesh mechanics including strength, compliance, anisotropy, nonlinearity and hysteresis.
引用
收藏
页码:411 / 427
页数:17
相关论文
共 109 条
[1]  
Amid PK., 1997, HERNIA, V1, P15, DOI DOI 10.1007/BF02426382
[2]   Biomechanical compatibility of surgical mesh and fascia being reinforced: dependence of experimental hernia defect repair results on anisotropic surgical mesh positioning [J].
Anurov, M. V. ;
Titkova, S. M. ;
Oettinger, A. P. .
HERNIA, 2012, 16 (02) :199-210
[3]   Collagen fibers in linea alba and rectus sheaths - I. General scheme and morphological aspects [J].
Axer, H ;
von Keyserlingk, DG ;
Prescher, A .
JOURNAL OF SURGICAL RESEARCH, 2001, 96 (01) :127-134
[4]   Effect of two loading rates on the elasticity of the human anterior rectus sheath [J].
Ben Abdelounis, H. ;
Nicolle, S. ;
Ottenio, M. ;
Beillas, P. ;
Mitton, D. .
JOURNAL OF THE MECHANICAL BEHAVIOR OF BIOMEDICAL MATERIALS, 2013, 20 :1-5
[5]   Which mesh for hernia repair? [J].
Brown, C. N. ;
Finch, J. G. .
ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2010, 92 (04) :272-278
[6]  
Burger JWA, 2004, ANN SURG, V240, P578
[7]  
Cardoso M., 2012, THESIS U PORTO
[8]   Remodeling characteristics and biomechanical properties of a crosslinked versus a non-crosslinked porcine dermis scaffolds in a porcine model of ventral hernia repair [J].
Cavallo, J. A. ;
Greco, S. C. ;
Liu, J. ;
Frisella, M. M. ;
Deeken, C. R. ;
Matthews, B. D. .
HERNIA, 2015, 19 (02) :207-218
[9]  
Cobb W, 2009, CENTRAL MESH FAILURE
[10]  
Cobb William S, 2005, Surg Innov, V12, P63, DOI 10.1177/155335060501200109