Mucin balls with wear of conventional and silicone hydrogel contact lenses

被引:24
作者
Tan, J
Keay, L
Jalbert, I
Naduvilath, TJ
Sweeney, DF [1 ]
Holden, BA
机构
[1] Univ New S Wales, Cooperat Res Ctr Eye Res & Technol, Sch Optometry & Vis Sci, Sydney, NSW 2052, Australia
[2] Univ New S Wales, Cornea & Contact Lens Res Unit, Sch Optometry & Vis Sci, Sydney, NSW 2052, Australia
关键词
soft contact lens; high Dk; silicone hydrogel; mucin balls; microdeposits; lipid plugs;
D O I
10.1097/00006324-200304000-00006
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose. To compare the frequency of mucin balls in subjects wearing conventional and high-Dk silicone hydrogel lenses during 12 months of extended-wear and to determine whether mucin balls are associated with any lens or subject characteristics. Methods. This study used data from a clinical trial where subjects wore either conventional hydrogel (N = 69, 6-night extended-wear) or silicone hydrogel (N = 70, 30-night extended-wear) contact lenses for 12 months. The number of mucin balls and other physiological responses, lens fit and performance, and subjective patient responses to lens wear were rated at each scheduled visit. Results. Subjects in the silicone hydrogel group had significantly greater numbers of mucin balls compared with subjects in the conventional hydrogel group over time (p < 0.001), but there were no significant differences in the percentage of subjects with mucin balls between the two groups. Increasing lens wettability, back surface deposits, and time of lens wear were associated with higher numbers of mucin balls in the conventional hydrogel group (p < 0.05); steeper corneal curvature and increasing lens wettability, back surface deposits, and number of microcysts were associated with higher numbers of mucin balls in the silicone hydrogel group (p < 0.05). Conclusions. This study indicates that a subset of the population is predisposed to develop mucin balls irrespective of the soft contact lens type worn, but lens type influences the degree of mucin ball formation. The relationship between lens wettability, back surface deposits, and steeper corneal curvature with mucin balls supports the hypothesis that the mechanical interaction of a lens with the surface layer of the epithelium and the tear film in association with the blinking forces of the lid is involved in mucin ball formation.
引用
收藏
页码:291 / 297
页数:7
相关论文
共 50 条
[31]   The effect of hydrogel and silicone hydrogel contact lenses on the measurement of intraocular pressure with rebound tonometry [J].
Zeri, Fabrizio ;
Calcatelli, Paolo ;
Donini, Bernardo ;
Lupelli, Luigi ;
Zarrilli, Luciana ;
Swann, Peter G. .
CONTACT LENS & ANTERIOR EYE, 2011, 34 (06) :260-265
[32]   Enhancing Performance of Silicone Hydrogel Contact Lenses with Hydrophilic Polyphenolic Coatings [J].
Demian, Paul ;
Nagaya, Daichi ;
Refaei, Roeya ;
Iwai, Kaoru ;
Hasegawa, Daiki ;
Baba, Masaki ;
Messersmith, Phillip B. ;
Lamrani, Mouad .
JOURNAL OF FUNCTIONAL BIOMATERIALS, 2024, 15 (11)
[33]   Clinical performance of different care systems with silicone hydrogel contact lenses [J].
Keir, Nancy ;
Woods, Craig A. ;
Dumbleton, Kathryn ;
Jones, Lyndon .
CONTACT LENS & ANTERIOR EYE, 2010, 33 (04) :189-195
[34]   Uptake and Release Phenomena in Contact Lens Care by Silicone Hydrogel Lenses [J].
Jones, Lyndon ;
Powell, Charles H. .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2013, 39 (01) :29-36
[35]   Deposition on Silicone Hydrogel Lenses [J].
Nichols, Jason J. .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2013, 39 (01) :20-23
[36]   Bacterial adhesion to conventional hydrogel and new silicone-hydrogel contact lens materials [J].
Laurent Kodjikian ;
Emmanuelle Casoli-Bergeron ;
Florence Malet ;
Hélène Janin-Manificat ;
Jean Freney ;
Carole Burillon ;
Joseph Colin ;
Jean-Paul Steghens .
Graefe's Archive for Clinical and Experimental Ophthalmology, 2008, 246 :267-273
[37]   Bacterial adhesion to conventional hydrogel and new silicone-hydrogel contact lens materials [J].
Kodjikian, Laurent ;
Casoli-Bergeron, Emmanuelle ;
Malet, Florence ;
Janin-Manificat, Helene ;
Freney, Jean ;
Burillon, Carole ;
Colin, Joseph ;
Steghens, Jean-Paul .
GRAEFES ARCHIVE FOR CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2008, 246 (02) :267-273
[38]   Bibliometric analysis of the literature relating to silicone hydrogel and daily disposable contact lenses [J].
Efron, Nathan ;
Jones, Lyndon W. ;
Morgan, Phillip B. ;
Nichols, Jason J. .
JOURNAL OF OPTOMETRY, 2022, 15 (01) :44-52
[39]   Tonopen XL Assessment of Intraocular Pressure Through Silicone Hydrogel Contact Lenses [J].
Schornack, Muriel ;
Rice, Melissa ;
Hodge, David .
EYE & CONTACT LENS-SCIENCE AND CLINICAL PRACTICE, 2012, 38 (05) :270-273
[40]   Micromechanical measurement of adhesion of dehydrating silicone hydrogel contact lenses to corneal tissue [J].
Zhu, Dongkai ;
Liu, Yangping ;
Gilbert, Jeremy L. .
ACTA BIOMATERIALIA, 2021, 127 :242-251