Evaluation of the 200 MWe Tonghae CFB boiler performance with cyclone modification

被引:14
作者
Lee, JM [1 ]
Kim, JS [1 ]
Kim, JJ [1 ]
机构
[1] Korea Elect Power Corp, Korea Elect Power Res Inst, Power Generat Lab, Adv Power Generat & Combust Grp,Yusang Gu, Taejon 305380, South Korea
关键词
D O I
10.1016/S0360-5442(02)00155-X
中图分类号
O414.1 [热力学];
学科分类号
摘要
The performance of the Tonghae CFB boiler with modification of the cyclone has been evaluated using the IEA-CFBC model. The effect of the cyclone efficiency on solid hold-up and pressure and temperature profiles in the combustor has been determined. From the calculated results, solid hold up in the lean phase of the combustor and pressure in the combustor increase, whereas solid hold-up in the dense phase and temperature in the combustor decrease as the cyclone efficiency increases. After modification of the cyclone through extension of the vortex finder and reduction of the width of the cyclone inlet duct, DeltaP(upper) (part) and DeltaP(lower) (part) in the combustor increase from 1328 to 1942 Pa and from 4402 to 4950 Pa, respectively. The temperature and the emission of SO2 of the combustor decrease after modification of the cyclone. Therefore, modification of the cyclone to improve its efficiency can allow operation and control of the Tonghae CFB boiler to be stable. The simulation results by the IEA-CFBC model can also explain well the improved performance of the CFB boiler. (C) 2003 Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:575 / 589
页数:15
相关论文
共 17 条
[1]  
Bellgardt D., 1987, P 9 INT C FLUID BED, P713
[2]  
BOEMER A, 1994, P 29 IEA FBC M PAR F
[3]  
CHELIAND PK, 1995, P 13 INT C FLUID BED, P535
[4]  
ERGUN S, 1952, CHEM ENG PROG, V48, P89
[5]  
Hannaes J, 1995, P 13 INT C FLUID BED, V1, P287
[6]  
HANNES J, 1996, THESIS DELFT U TECHN
[7]  
KIM JS, 1998, P 2 KOR CHIN JOINT W, P445
[8]  
Kunii D., 1991, FLUIDIZATION ENG
[9]   Simulation of the 200 MWe Tonghae thermal power plant circulating fluidized bed combustor by using IEA-CFBC model [J].
Lee, JM ;
Kim, JS .
KOREAN JOURNAL OF CHEMICAL ENGINEERING, 1999, 16 (05) :640-645
[10]  
MAITLAND J, 1997, P 14 INT C FLUID BED, P191