Temperature controlled ionic liquid-based dispersive micro-extraction using two ligands, for determination of aluminium in scalp hair samples of Alzheimer's patients: A multivariate study

被引:44
作者
Arain, Mariam S. [1 ]
Arain, Salma A. [1 ]
Kazi, Tasneem G. [1 ]
Afridi, Hassan I. [1 ]
Ali, Jamshaid [1 ]
Naeemulllah [1 ]
Arain, Sadaf S. [1 ]
Brahman, Kapil Dev [1 ]
Mughal, Moina Akhtar [2 ]
机构
[1] Univ Sindh, Natl Ctr Excellence Analyt Chem, Jamshoro 76080, Pakistan
[2] Univ Sindh, Dr MA Kazi Inst Chem, Jamshoro 76080, Pakistan
关键词
Aluminium; 1-Hexyl-3-methylimidazolium; hexafluorophosphate; 8-Hydroxyquinoline; 3,5,7,2 '-4 ' Pentahydroxy flavone; Dispersive liquid-liquid microextraction; Alzheimer's disease; CLOUD POINT EXTRACTION; ATOMIC-ABSORPTION-SPECTROMETRY; MULTIWALLED CARBON NANOTUBES; SOLID-PHASE EXTRACTION; MICELLE-MEDIATED METHODOLOGY; SINGLE-DROP MICROEXTRACTION; TRACE ALUMINUM; DRINKING-WATER; NATURAL-WATERS; METAL-IONS;
D O I
10.1016/j.saa.2014.08.068
中图分类号
O433 [光谱学];
学科分类号
0703 ; 070302 ;
摘要
A green and sensitive temperature controlled dispersive liquid-liquid microextraction (TIL-DLLME) methodology based on the application of ionic liquid 1-butyl-3-methylimidazolium hexafluorophosphate, [C(4)mim][PF6], as an extractant solvent was proposed for the preconcentration of trace levels of aluminium (Al3+) in scalp hair samples of Alzheimer's (AD) patients, prior to analyzing by flame atomic absorption spectrometry (FAAS). The Al3+ was complexed with 8-hydrooxyquinoline (oxine) (L-1) and 3,5,7,2'-4' pentahydroxy flavone (morin) (L-2) separately and then extracted by IL at temperature (50 +/- 2.0 degrees C). Some effective factors that influence the TIL-DLLME efficiency such as pH, ligands concentrations, volume of IL, ionic strength, and incubation time were investigated and optimized by multivariate analysis. In the optimum experimental conditions, the limit of detection (3 s) and enhancement factor were 0.56 mu g L-1, 0.64 mu g L-1 and 85, 73 for both ligands, respectively. The relative standard deviation (RSD) for six replicate determinations of 100 mu g L-1 Al3+ complexed with oxine and morn were found to be 3.88% and 4.74%, respectively. The developed method was validated by the analysis of certified reference material of human hair (NCSZC81002).and applied satisfactorily to the determination of Al3+ in acid digested scalp hair samples of AD patients and healthy controls. The resulted data shows significant higher level in scalp hair samples of AD male patients with related to referents of same age and socioeconomic status. (C) 2014 Elsevier B.V. All rights reserved.
引用
收藏
页码:877 / 885
页数:9
相关论文
共 60 条
  • [1] Combination of ionic liquid-based dispersive liquid-liquid micro-extraction with stopped-flow spectrofluorometry for the pre-concentration and determination of aluminum in natural waters, fruit juice and food samples
    Abdolmohammad-Zadeh, H.
    Sadeghi, G. H.
    [J]. TALANTA, 2010, 81 (03) : 778 - 785
  • [2] Direct coupling of ionic liquid based single-drop microextraction and GC/MS
    Aguilera-Heirador, Eva
    Lucena, Rafael
    Cardenas, Soledad
    Valcarcel, Miguel
    [J]. ANALYTICAL CHEMISTRY, 2008, 80 (03) : 793 - 800
  • [3] Alexandrov PN, 2005, J ALZHEIMERS DIS, V8, P117
  • [4] Amjadi M., 2012, RES PHARM SCI, V7, pS652
  • [5] [Anonymous], 1997, 194 IPCS WHO, P138
  • [6] Investigation of Alteration in the Levels of Iron and Copper in Scalp Hair Samples of Patients Having Different Types of Viral Hepatitis
    Arain, Salma Aslam
    Afridi, Hassan Imran
    Kazi, Tasneem G.
    Talpur, Farah Naz
    Shah, Faheem
    Arain, Sadaf Sadia
    Panhwar, Abdul Haleem
    Brahman, Kapil Dev
    [J]. BIOLOGICAL TRACE ELEMENT RESEARCH, 2013, 156 (1-3) : 5 - 11
  • [7] Aluminum complexing enhances amyloid β protein penetration of blood-brain barrier
    Banks, William A.
    Niehoff, Michael L.
    Drago, Denise
    Zatta, Paolo
    [J]. BRAIN RESEARCH, 2006, 1116 : 215 - 221
  • [8] Aluminum as a toxicant
    Becaria, A
    Campbell, A
    Bondy, SC
    [J]. TOXICOLOGY AND INDUSTRIAL HEALTH, 2002, 18 (07) : 309 - 320
  • [9] Ionic liquids in separation techniques
    Berthod, A.
    Ruiz-Angel, Mt
    Carda-Broch, S.
    [J]. JOURNAL OF CHROMATOGRAPHY A, 2008, 1184 (1-2) : 6 - 18
  • [10] Quantification of trace elements by sector field inductively coupled plasma mass spectrometry in urine, serum, blood and cerebrospinal fluid of patients with Parkinson's disease
    Bocca, B
    Alimonti, A
    Petrucci, F
    Violante, N
    Sancesario, G
    Forte, G
    Senofonte, O
    [J]. SPECTROCHIMICA ACTA PART B-ATOMIC SPECTROSCOPY, 2004, 59 (04) : 559 - 566