Accurate Doppler Radar Noncontact Vital Sign Detection Using the RELAX Algorithm

被引:137
作者
Li, Changzhi [1 ]
Ling, Jun [1 ]
Li, Jian [1 ]
Lin, Jenshan [1 ]
机构
[1] Univ Florida, Dept Elect & Comp Engn, Gainesville, FL 32611 USA
关键词
Doppler radar; noncontact; nonlinear phase modulation; periodogram; spectral estimation; the RELAX algorithm; vital sign detection; HEARTBEAT; MOVEMENT;
D O I
10.1109/TIM.2009.2025986
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We consider using a Doppler radar for accurate noncontact vital sign detection. The Doppler radar first captures and downconverts the wireless signal that is phase modulated by the physiological movements, and then identifies the human heartbeat and respiration rates by processing the baseband signal. When nonlinear Doppler phase modulation is employed to monitor vital signs without contact, one of the challenges that we encounter is the presence of undesired harmonic terms and intermodulations other than the sinusoids of interest. A spectral estimation algorithm is needed to accurately estimate the sinusoidal frequencies before identifying the heartbeat and respiration rates. The conventional periodogram cannot reliably separate the rich sinusoidal components since it suffers from smearing and leakage problems, particularly for the case of limited data samples. A parametric and cyclic optimization approach, referred to as the RELAX algorithm, is instead suggested to mitigate these difficulties. Both simulated and experimental results are provided to validate the superiority of using the RELAX algorithm for accurate noncontact vital sign detection.
引用
收藏
页码:687 / 695
页数:9
相关论文
共 20 条
[1]  
[Anonymous], 2005, SPECTRAL ANAL SIGNAL
[2]   Microwave life-detection systems for searching human subjects under earthquake rubble or behind barrier [J].
Chen, KM ;
Huang, Y ;
Zhang, JP ;
Norman, A .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2000, 47 (01) :105-114
[3]   Range correlation and I/Q performance benefits in single-chip silicon Doppler radars for noncontact cardiopulmonary monitoring [J].
Droitcour, AD ;
Boric-Lubecke, O ;
Lubecke, VM ;
Lin, JS ;
Kovacs, GTA .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2004, 52 (03) :838-848
[4]  
Gao WH, 2007, IEEE WCNC, P2802
[5]   MATRIX PENCIL METHOD FOR ESTIMATING PARAMETERS OF EXPONENTIALLY DAMPED UNDAMPED SINUSOIDS IN NOISE [J].
HUA, Y ;
SARKAR, TK .
IEEE TRANSACTIONS ON ACOUSTICS SPEECH AND SIGNAL PROCESSING, 1990, 38 (05) :814-824
[6]   GENERALIZED PENCIL-OF-FUNCTION METHOD FOR EXTRACTING POLES OF AN EM SYSTEM FROM ITS TRANSIENT-RESPONSE [J].
HUA, Y ;
SARKAR, TK .
IEEE TRANSACTIONS ON ANTENNAS AND PROPAGATION, 1989, 37 (02) :229-234
[7]   Experiment and spectral analysis of a low-power Ka-band heartbeat detector measuring from four sides of a human body [J].
Li, Changzhi ;
Xiao, Yanming ;
Lin, Jenshan .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2006, 54 (12) :4464-4471
[8]  
Li CZ, 2008, IEEE MTT-S, P566
[9]   Random Body Movement Cancellation in Doppler Radar Vital Sign Detection [J].
Li, Changzhi ;
Lin, Jenshan .
IEEE TRANSACTIONS ON MICROWAVE THEORY AND TECHNIQUES, 2008, 56 (12) :3143-3152
[10]   Efficient mixed-spectrum estimation with applications to target feature extraction [J].
Li, J ;
Stoica, P .
IEEE TRANSACTIONS ON SIGNAL PROCESSING, 1996, 44 (02) :281-295