ULTRASOUND DIAGNOSIS OF TYPE A AORTIC DISSECTION

被引:19
作者
Perkins, Alisha M. [1 ]
Liteplo, Andrew [1 ]
Noble, Vicki E. [1 ]
机构
[1] Massachusetts Gen Hosp, Dept Emergency Med, Boston, MA 02114 USA
关键词
aortic dissection; ultrasound; thoracic aortic dissection; type A dissection; intimal flap; ECHOCARDIOGRAPHY; ACCURACY;
D O I
10.1016/j.jemermed.2008.05.013
中图分类号
R4 [临床医学];
学科分类号
1002 ; 100602 ;
摘要
Background: An aortic dissection is a life-threatening process that must be diagnosed and treated expeditiously. Imaging modalities used for diagnosis in the emergency department include computed tomography, magnetic resonance imaging, and trans-esophageal echocardiography. There are significant limitations to these studies, including patient contraindications (intravenous contrast dye allergies, renal insufficiency, metal-containing implants, hemodynamic instability) and the length of time required for study completion and interpretation by a radiologist or cardiologist. Objectives: A case is presented that demonstrates how emergency physicians can use transthoracic and abdominal bedside ultrasound to diagnose a type A aortic dissection. Case Report: A 72-year-old woman presented with chest pain radiating to her neck and back that was concerning for aortic dissection. This was subsequently confirmed and further classified as a type A dissection by bedside emergency physician-performed ultrasound. The images showed a clear intimal flap in the abdominal aorta, a dilatated aortic root, and extension of the intimal flap into the left common carotid artery. With prompt diagnosis, the patient was able to have emergent surgical consultation, confirmatory imaging, and intervention before further complication occurred. Conclusion: This case provides an example of how emergency transthoracic and abdominal ultrasound can be used to promptly diagnose a type A aortic dissection and expedite further consultation and prompt management. (C) 2010 Elsevier Inc.
引用
收藏
页码:490 / 493
页数:4
相关论文
共 5 条
  • [1] The International Registry of Acute Aortic Dissection (IRAD) - New insights into an old disease
    Hagan, PG
    Nienaber, CA
    Isselbacher, EM
    Bruckman, D
    Karavite, DJ
    Russman, PL
    Evangelista, A
    Fattori, R
    Suzuki, T
    Oh, JK
    Moore, AG
    Malouf, JF
    Pape, LA
    Gaca, C
    Sechtem, U
    Lenferink, S
    Deutsch, HJ
    Diedrichs, H
    Robles, JMY
    Llovet, A
    Gilon, D
    Das, SK
    Armstrong, WF
    Deeb, GM
    Eagle, KA
    [J]. JAMA-JOURNAL OF THE AMERICAN MEDICAL ASSOCIATION, 2000, 283 (07): : 897 - 903
  • [2] Khandheria B K, 1989, J Am Soc Echocardiogr, V2, P17
  • [3] ACCURACY OF M-MODE AND TWO-DIMENSIONAL ECHOCARDIOGRAPHY IN THE DIAGNOSIS OF AORTIC DISSECTION - AN EXPERIENCE WITH 128 CASES
    ROUDAUT, RP
    BILLES, MA
    GOSSE, P
    DEVILLE, C
    BAUDET, E
    FONTAN, F
    BESSE, P
    BRICAUD, H
    DALLOCCHIO, M
    [J]. CLINICAL CARDIOLOGY, 1988, 11 (08) : 553 - 562
  • [4] Diagnostic accuracy of transesophageal echocardiography, helical computed tomography, and magnetic resonance imaging for suspected thoracic aortic dissection - Systematic review and meta-analysis
    Shiga, Toshiya
    Wajima, Zen'ichiro
    Apfel, Christian C.
    Inoue, Tetsuo
    Ohe, Yoko
    [J]. ARCHIVES OF INTERNAL MEDICINE, 2006, 166 (13) : 1350 - 1356
  • [5] TWO-DIMENSIONAL ECHOCARDIOGRAPHIC DIAGNOSIS OF AORTIC DISSECTION
    VICTOR, MF
    MINTZ, GS
    KOTLER, MN
    WILSON, AR
    SEGAL, BL
    [J]. AMERICAN JOURNAL OF CARDIOLOGY, 1981, 48 (06) : 1155 - 1159