Proposal for a new approach to corneal biomechanics: dynamic corneal topography

被引:8
作者
Bonatti, Jose Americo [1 ]
Bechara, Samir Jacob [1 ]
Carricondo, Pedro Carlos [1 ]
Kara-Jose, Newton [1 ]
机构
[1] Univ Sao Paulo, Biotechnol & Bioengn Res Grp, Refract Surg Sect, Lab Invest Med LIM 33, Sao Paulo, Brazil
关键词
Corneal topography/methods; Microscopy; video/methods; Biomechanics; Image processing; computer-assisted/methods; Diagnostic techniques; ophthalmological/methods; Refractive surgical procedures; TEAR FILM; HUMAN EYE; ABERRATIONS;
D O I
10.1590/S0004-27492009000200028
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: To establish the literature basis that could support the idea that it would be possible to analyze changes at the anterior surface of the cornea induced by an air jet applied onto the eye. Methods: The PUBMED/MEDLINE literature basis regarding the following subjects was searched: videokeratography, high-speed photography, ocular response analyzer ( ORA). The information concerning the goal of this paper was selected. Results: The literature showed data that support the idea of gathering 3 nowadays available technologies that could result in a new concept of "dynamic corneal topography": the corneal topography, the air jet applied to histeresis measurement by the Ocular Response Analyzer (R) and the high-speed photography technique used to study the tear film and the anterior surface of the cornea. Conclusion: The literature basis supports the idea of gathering the existent technologies of corneal topography, the air jet of the corneal histeresis device and the high-speed photography to create a new concept in the analysis of the corneal surface: the dynamic corneal topography.
引用
收藏
页码:264 / 267
页数:4
相关论文
共 12 条
[1]   Fluctuations in intraocular pressure and the potential effect on aberrations of the eye [J].
Asejczyk-Widlicka, M. ;
Pierscionek, B. K. .
BRITISH JOURNAL OF OPHTHALMOLOGY, 2007, 91 (08) :1054-1058
[2]  
Collins Michael J, 2006, Eye Contact Lens, V32, P287, DOI 10.1097/01.icl.0000224551.58399.9a
[3]   The brilliant beauty of the eye - Light reflex from the cornea and tear film [J].
Goto, Eiki .
CORNEA, 2006, 25 (10) :S78-S81
[4]   Optical aberrations and visual disturbances associated with dry eye [J].
Goto, Eiki ;
Ishida, Reiko ;
Kaido, Minako ;
Dogru, Murat ;
Matsumoto, Yukihiro ;
Kojima, Takashi ;
Tsubota, Kazuo .
OCULAR SURFACE, 2006, 4 (04) :207-213
[5]   Dynamic corneal imaging [J].
Grabner, G ;
Ellmsteiner, R ;
Steindl, C ;
Ruckhofer, J ;
Mattioli, R ;
Husinsky, W .
JOURNAL OF CATARACT AND REFRACTIVE SURGERY, 2005, 31 (01) :163-174
[6]   Curvature sensor for the measurement of the static corneal topography and the dynamic tear film topography in the human eye [J].
Gruppetta, S ;
Koechlin, L ;
Lacombe, FO ;
Puget, P .
OPTICS LETTERS, 2005, 30 (20) :2757-2759
[7]  
Iskander D Robert, 2005, Clin Exp Optom, V88, P223
[8]   Evaluating tear film stability in the human eye with high-speed videokeratoscopy [J].
Iskander, DR ;
Collins, MJ ;
Davis, B .
IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 2005, 52 (11) :1939-1949
[9]   Corneal hysteresis using the Reichert ocular response analyser: findings pre- and post-LASIK and LASEK [J].
Kirwan, Caitriona ;
O'Keefe, Michael .
ACTA OPHTHALMOLOGICA, 2008, 86 (02) :215-218
[10]   Temporal changes in optical quality of air-tear film interface at anterior cornea after blink [J].
Montés-Micó, R ;
Alió, JL ;
Muñoz, G ;
Charman, WN .
INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2004, 45 (06) :1752-1757