Optical link based readout system for Medipix2 quad X-ray detector

被引:1
作者
Fanti, V.
Marzeddu, R.
Randaccio, P.
Aloisio, A.
Del Guerra, A.
Lanconelli, N.
Mettivier, G.
Montesi, M. C.
Pani, R.
Russo, P.
机构
[1] Univ Cagliari, I-09042 Monserrato, CA, Italy
[2] INFN Sez Cagliari, I-09042 Monserrato, CA, Italy
[3] Univ Bologna, I-40127 Bologna, BO, Italy
[4] INFN Sez Bologna, I-40127 Bologna, BO, Italy
[5] Univ Naples Federico II, I-80126 Naples, NA, Italy
[6] INFN Sez Napoli, I-80126 Naples, NA, Italy
[7] Univ Pisa, I-56127 Pisa, PI, Italy
[8] INFN Sez Pisa, I-56127 Pisa, PI, Italy
[9] Univ Roma La Sapienza, I-00161 Rome, RO, Italy
关键词
X-ray imaging; data acquisition; PCI interface; optical link;
D O I
10.1016/j.nima.2007.01.141
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
An imaging system based on the Medipix2, a single photon counting pixel readout ASIC for X-ray hybrid detectors, has been developed for tomography imaging applications. The "quad assembly" houses four Medipix2 chips placed in a 2 x 2 array with an active area of about 3 x 3 cm(2). The readout system we present consists of four electronic cards and exploits the Medipix2 parallel readout mode and a fast optical link based on the Glink standard, giving high flexibility and EM interference immunity over long distance connections. A PCI board interfaces the imaging system to a standard PC. We expect a frame rate of 25 frame/s which allows real-time X-ray imaging acquisitions and fast computed tomography (CT) scanning. In this paper, we describe the DAQ project and the status of development. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:137 / 141
页数:5
相关论文
共 7 条
[1]   An interface board for the control and data acquisition of the Medipix2 chip [J].
Bello, DS ;
van Beuzekom, M ;
Jansweijer, P ;
Verkooijen, H ;
Visschers, J .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 509 (1-3) :164-170
[2]  
CLEMENT J, 2006, P IWORID
[3]   Medipix2 parallel readout system [J].
Fanti, V ;
Marzeddu, R ;
Randaccio, P .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 509 (1-3) :171-175
[4]   PCI card with DMA capabilities for digital imaging detectors [J].
Fanti, Viviana ;
Marzeddu, Roberto ;
Randaccio, Paolo .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01) :108-111
[5]   Medipix2:: a 64-k pixel readout chip with 55 μm square elements working in single photon counting mode [J].
Llopart, X ;
Campbell, M ;
Dinapoli, R ;
Segundo, DS ;
Pemigotti, E .
IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2002, 49 (05) :2279-2283
[6]   A read-out system for the Medipix2 chip capable of 500 frames per second [J].
Maiorino, M ;
Martinez, R ;
Pellegrini, G ;
Blanchot, G ;
Chmeissani, M ;
Garcia, J ;
Lozano, M ;
Puigdengoles, C ;
Ullan, M .
NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 563 (01) :96-99
[7]   USB interface for Medipix2 pixel device enabling energy and position-sensitive detection of heavy charged particles [J].
Vykydal, Z ;
Jakubek, J ;
Pospisil, S .