Point x-ray source using graphite nanofibers and its application to x-ray radiography

被引:52
作者
Matsumoto, T
Mimura, H
机构
[1] Stanley Elect Corp, Ctr Res & Dev, Yokohama, Kanagawa 2250014, Japan
[2] Tohoku Univ, Elect Commun Res Inst, Sendai, Miyagi 9808577, Japan
关键词
D O I
10.1063/1.1558969
中图分类号
O59 [应用物理学];
学科分类号
摘要
A point x-ray emission was obtained from a diode configuration composed of a graphite-nanofiber cold cathode and a conical-shaped copper metal anode. When combined with a highly sensitive charge coupled device (CCD) camera with a scintillator, this x-ray source was then used to obtain x-ray transmission images of a tungsten mesh and an x-ray test chart. The spatial resolution of this x-ray radiography system was on the order of 10 mum and the acquisition time for these images was less than 10 s. This combination of the point x-ray source and the sensitive detection system offers a high-resolution x-ray radiography system. (C) 2003 American Institute of Physics.
引用
收藏
页码:1637 / 1639
页数:3
相关论文
共 8 条
[1]   A CARBON NANOTUBE FIELD-EMISSION ELECTRON SOURCE [J].
DEHEER, WA ;
CHATELAIN, A ;
UGARTE, D .
SCIENCE, 1995, 270 (5239) :1179-1180
[2]   Electron emission in intense electric fields [J].
Fowler, RH ;
Nordheim, L .
PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-CONTAINING PAPERS OF A MATHEMATICAL AND PHYSICAL CHARACTER, 1928, 119 (781) :173-181
[3]   EFFICIENCY OF PRODUCTION OF CHARACTERISTIC X-RADIATION IN THICK TARGETS OF A PURE ELEMENT [J].
GREEN, M ;
COSSLETT, VE .
PROCEEDINGS OF THE PHYSICAL SOCIETY OF LONDON, 1961, 78 (505) :1206-&
[4]  
Hirakawa M., 2000, IDW '00. Proceedings of the Seventh International Display Workshops, P1027
[5]   RANGE OF ELECTRONS AND POSITRONS [J].
MUKOYAMA, T .
NUCLEAR INSTRUMENTS & METHODS, 1976, 134 (01) :125-127
[6]   Carbon nanotubes as electron source in an x-ray tube [J].
Sugie, H ;
Tanemura, M ;
Filip, V ;
Iwata, K ;
Takahashi, K ;
Okuyama, F .
APPLIED PHYSICS LETTERS, 2001, 78 (17) :2578-2580
[7]   Fabrication of nitrogen-doped diamond field emitter utilizing porous silicon and molding technique [J].
Takida, T ;
Inoue, K ;
Ri, SG ;
Kimura, H ;
Kiyota, H ;
Saito, I ;
Kurosu, T ;
Iida, M .
JAPANESE JOURNAL OF APPLIED PHYSICS PART 2-LETTERS, 2000, 39 (1AB) :L56-L58
[8]   Generation of continuous and pulsed diagnostic imaging x-ray radiation using a carbon-nanotube-based field-emission cathode [J].
Yue, GZ ;
Qiu, Q ;
Gao, B ;
Cheng, Y ;
Zhang, J ;
Shimoda, H ;
Chang, S ;
Lu, JP ;
Zhou, O .
APPLIED PHYSICS LETTERS, 2002, 81 (02) :355-357