Assessment of PMU-based wide-area angle criterion for fault detection in microgrid

被引:31
|
作者
Sharma, Nikhil Kumar [1 ]
Samantaray, Subhransu Ranjan [1 ]
机构
[1] Indian Inst Technol, Sch Elect Sci, Bhubaneswar, India
关键词
distributed power generation; fault diagnosis; synchronisation; phasor measurement; power system measurement; power distribution faults; power distribution system; serious protection challenges; effective fault detection scheme; reliable fault detection scheme; present-day microgrid environment; phasor measurement unit-based wide-area phase angle criterion; protection system; voltage phase angle difference; fault point; accurate measurement; faithful measurement; faulted conditions; phasor data concentrator; time synchronised phasor data; protection index; effective fault detection measure; microgrid including large variations; PMU-based wide-area angle criterion; distributed generation; DISTRIBUTION NETWORKS; DISTRIBUTION-SYSTEMS; PROTECTION SCHEME; SYNCHROPHASORS;
D O I
10.1049/iet-gtd.2019.0027
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The penetration of distributed generation in the power distribution system has increased significantly in recent years, bringing serious protection challenges. Hence, it is mandated to develop effective and reliable fault detection scheme for present-day microgrid environment. This study presents a phasor measurement unit-based (PMU) wide-area phase angle criterion for building a protection system for the microgrid. The absolute value of the rate of change of voltage phase angle difference between the point of common coupling and the bus closest to the fault point is utilised for fault detection in grid connected as well as in the islanded modes of operation. C37.118.1 complied PMUs are employed at the appropriate locations for accurate and faithful measurement of voltage phase angle and the rate of angle difference (RAD) for detecting faulted conditions. PMUs are connected to phasor data concentrator, which receives the time synchronised phasor data and acts as a centralised processing unit. The proposed protection index has been extensively validated on MATLAB/Simulink environment as well as the real-time digital simulator with external PMUs. The test results show that the proposed RAD is a potential candidate for providing effective fault detection measure for microgrid including large variations in operating conditions.
引用
收藏
页码:4301 / 4310
页数:10
相关论文
共 50 条
  • [31] Fault Location Method Based on Wide-Area Voltage
    Xu, Yan
    Ying, Lu-man
    Zhi, Jing
    Feng, Ren-qing
    ENERGY DEVELOPMENT, PTS 1-4, 2014, 860-863 : 2077 - +
  • [32] A Novel Wide-area Fault Location Algorithm Based on Fault Model
    Ma, Jing
    Li, Jin-long
    Wang, Zeng-ping
    Yang, Qi-Xun
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [33] A novel wide-area fault location algorithm based on fault model
    Ma, Jing
    Li, Jin-Long
    Li, Jin-Hui
    Yang, Qi-Xun
    Wang, Zeng-Ping
    Dianli Xitong Baohu yu Kongzhi/Power System Protection and Control, 2010, 38 (20): : 74 - 78
  • [34] A PMU-based back-up protection scheme for fault detection considering uncertainties
    Shazdeh, Sirwan
    Golpira, Hemin
    Bevrani, Hassan
    INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2023, 145
  • [35] Fault Assessment of Circuit Breakers Based on Wide-Area Generalization Information and Improved ACGAN
    Sun, Shuguang
    Yang, Feilong
    Wang, Jingqin
    Li, Ruijie
    Wang, Zewei
    IEEE SENSORS JOURNAL, 2023, 23 (20) : 24954 - 24969
  • [36] A Study of Communication and Power System Infrastructure Interdependence on PMU-based Wide Area Monitoring and Protection
    Lin, Hua
    Sambamoorthy, Santosh
    Shukla, Sandeep
    Thorp, James
    Mili, Lamine
    2012 IEEE POWER AND ENERGY SOCIETY GENERAL MEETING, 2012,
  • [37] A PMU-based Dynamic Fault Location Estimation for Transmission Lines
    He Wen
    He Zhengyou
    Mai Ruikun
    2010 ASIA-PACIFIC POWER AND ENERGY ENGINEERING CONFERENCE (APPEEC), 2010,
  • [38] Wide-Area Wide-Angle SAR Focusing
    Dungan, Kerry E.
    Nehrbass, John W.
    IEEE AEROSPACE AND ELECTRONIC SYSTEMS MAGAZINE, 2014, 29 (01) : 21 - 28
  • [39] PMU-Based Detection of Voltage Imbalances with Tolerance Constraints
    Routtenberg, Tirza
    Concepcion, Ricky
    Tong, Lang
    IEEE TRANSACTIONS ON POWER DELIVERY, 2017, 32 (01) : 484 - 494
  • [40] Wide-Area Damping Control for Interarea Oscillations in Power Grids Based on PMU Measurements
    Zenelis, Ilias
    Wang, Xiaozhe
    IEEE CONTROL SYSTEMS LETTERS, 2018, 2 (04): : 719 - 724