Assessment of PMU-based wide-area angle criterion for fault detection in microgrid

被引:31
作者
Sharma, Nikhil Kumar [1 ]
Samantaray, Subhransu Ranjan [1 ]
机构
[1] Indian Inst Technol, Sch Elect Sci, Bhubaneswar, India
关键词
distributed power generation; fault diagnosis; synchronisation; phasor measurement; power system measurement; power distribution faults; power distribution system; serious protection challenges; effective fault detection scheme; reliable fault detection scheme; present-day microgrid environment; phasor measurement unit-based wide-area phase angle criterion; protection system; voltage phase angle difference; fault point; accurate measurement; faithful measurement; faulted conditions; phasor data concentrator; time synchronised phasor data; protection index; effective fault detection measure; microgrid including large variations; PMU-based wide-area angle criterion; distributed generation; DISTRIBUTION NETWORKS; DISTRIBUTION-SYSTEMS; PROTECTION SCHEME; SYNCHROPHASORS;
D O I
10.1049/iet-gtd.2019.0027
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
The penetration of distributed generation in the power distribution system has increased significantly in recent years, bringing serious protection challenges. Hence, it is mandated to develop effective and reliable fault detection scheme for present-day microgrid environment. This study presents a phasor measurement unit-based (PMU) wide-area phase angle criterion for building a protection system for the microgrid. The absolute value of the rate of change of voltage phase angle difference between the point of common coupling and the bus closest to the fault point is utilised for fault detection in grid connected as well as in the islanded modes of operation. C37.118.1 complied PMUs are employed at the appropriate locations for accurate and faithful measurement of voltage phase angle and the rate of angle difference (RAD) for detecting faulted conditions. PMUs are connected to phasor data concentrator, which receives the time synchronised phasor data and acts as a centralised processing unit. The proposed protection index has been extensively validated on MATLAB/Simulink environment as well as the real-time digital simulator with external PMUs. The test results show that the proposed RAD is a potential candidate for providing effective fault detection measure for microgrid including large variations in operating conditions.
引用
收藏
页码:4301 / 4310
页数:10
相关论文
共 30 条
  • [1] Performance of communication networks for Integrity protection systems based on travelling wave with IEC 61850
    Ali, N. H.
    Ali, Borhanuddin M.
    Othman, Mohammad Lutfi
    Abdel-Latif, K. M.
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2018, 95 : 664 - 675
  • [2] ANDERSON PM, 1999, POWER SYSTEM PROTECT, P201
  • [3] [Anonymous], ELECT POWER COMPONEN
  • [4] [Anonymous], C371181A2014 IEEE, P1
  • [5] [Anonymous], 2014, IEEE ISGT, DOI DOI 10.1109/ISGT.2014.6816509
  • [6] Bollen MHJ, 2000, INT C HARMON QUAL PO, P193, DOI 10.1109/ICHQP.2000.897023
  • [7] A Differential Sequence Component Protection Scheme for Microgrids With Inverter-Based Distributed Generators
    Casagrande, E.
    Woon, W. L.
    Zeineldin, H. H.
    Svetinovic, D.
    [J]. IEEE TRANSACTIONS ON SMART GRID, 2014, 5 (01) : 29 - 37
  • [8] Distance relaying of 11Kv circuits to increase the installed capacity of distributed generation
    Chilvers, I
    Jenkins, N
    Crossley, P
    [J]. IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2005, 152 (01) : 40 - 46
  • [9] Performance of Interconnection Protection Based on Distance Relaying for Wind Power Distributed Generation
    El-Arroudi, Khalil
    Joos, Geza
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2018, 33 (02) : 620 - 629
  • [10] Power System Real-Time Event Detection and Associated Data Archival Reduction Based on Synchrophasors
    Ge, Yinyin
    Flueck, Alexander J.
    Kim, Dae-Kyeong
    Ahn, Jong-Bo
    Lee, Jae-Duck
    Kwon, Dae-Yun
    [J]. IEEE TRANSACTIONS ON SMART GRID, 2015, 6 (04) : 2088 - 2097