Inflow Cannula Position Influences Improvement in Mitral Regurgitation After Ventricular Assist Device Implantation

被引:6
作者
Pasrija, Chetan [1 ]
Sawan, Mariem A. [2 ]
Sorensen, Erik [3 ]
Gammie, James S. [1 ]
Madathil, Ronson [1 ]
Tran, Douglas [1 ]
Wang, Libin [2 ]
Ton, Van-Khue [2 ]
Feller, Erika [2 ]
Griffith, Bartley P. [1 ]
Kon, Zachary N. [4 ]
Kaczorowski, David J. [1 ]
机构
[1] Univ Maryland, Sch Med, Dept Surg, Div Cardiac Surg, Baltimore, MD 21201 USA
[2] Univ Maryland, Sch Med, Dept Med, Baltimore, MD 21201 USA
[3] Univ Maryland, Med Ctr, Div Clin Engn, Baltimore, MD 21201 USA
[4] New York Univ Langone Hlth, Dept Cardiothorac Surg, New York, NY USA
关键词
left ventricular assist device; mitral regurgitation; heart failure; REPAIR;
D O I
10.1097/MAT.0000000000001248
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Significant residual mitral regurgitation (MR) after left ventricular assist device (LVAD) implantation has been associated with increased morbidity and mortality. The effect of cannula position on improvement of preexisting MR has yet to be evaluated. Consecutive patients who underwent centrifugal LVAD implantation with >mild preoperative MR and without concomitant mitral repair were reviewed. Left ventricular assist device position was determined by the angle between actual and ideal inflow cannula on computed tomography. The magnitudes of angles (anterior and lateral angle) were added to form an LVAD position assessment (LVADpa). Mitral regurgitation was numerically classified, and improvement in MR was determined by difference in MR preoperatively to MR >1 month postoperatively with a median of 162 (interquartile range: 78-218) days. The primary analysis examined the relationship between LVADpa and postoperative MR. Forty-one patients were identified with >mild preoperative functional MR. Mean age was 51 +/- 13 years with an ejection fraction of 16 +/- 4%. Overall, MR improved from moderate-severe preoperatively to mild postoperatively (p < 0.001). On multivariable analysis, higher LVADpa deviation was associated with greater postoperative MR (odds ratio [OR] = 2.29, p = 0.005) and higher 1-month pulsatility index was associated with lower postoperative MR (OR = 0.47, p = 0.011). Inflow cannula position during centrifugal LVAD implantation is an important determinant of postoperative MR.
引用
收藏
页码:423 / 429
页数:7
相关论文
共 50 条
[21]   Pre-operative echocardiographic features associated with persistent mitral regurgitation after left ventricular assist device implantation [J].
Kitada, Shuichi ;
Kato, Tomoko S. ;
Thomas, Sunu S. ;
Conwell, Suzanne D. ;
Russo, Cesare ;
Di Tullio, Marco R. ;
Farr, Maryjane ;
Schulze, P. Christian ;
Uriel, Nir ;
Jorde, Ulrich P. ;
Takayama, Hiroo ;
Naka, Yoshifumi ;
Homma, Shunichi ;
Mancini, Donna M. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2013, 32 (09) :897-904
[22]   Impact of severe mitral regurgitation on postoperative outcome after durable left-ventricular assist device implantation [J].
Zubarevich, Alina ;
Szczechowicz, Marcin ;
Arjomandi Rad, Arian ;
Osswald, Anja ;
Papathanasiou, Maria ;
Luedike, Peter ;
Koch, Achim ;
Pizanis, Nikolaus ;
Kamler, Markus ;
Schmack, Bastian ;
Ruhparwar, Arjang ;
Weymann, Alexander .
ARTIFICIAL ORGANS, 2022, 46 (05) :953-963
[23]   Impact of Baseline Mitral Regurgitation on Postoperative Outcomes After Left Ventricular Assist Device Implantation as Destination Therapy [J].
Okoh, A. ;
Yanagida, R. ;
Schultheis, M. ;
Chaudari, S. ;
Fugar, S. ;
Nnaoma, C. ;
Chan, O. ;
Zucker, M. J. ;
Karanam, R. ;
Russo, M. J. ;
Camacho, M. .
TRANSPLANTATION PROCEEDINGS, 2019, 51 (03) :859-864
[24]   Presentation and management of left ventricular assist device inflow cannula malposition [J].
Milano, Carmelo A. ;
Simeone, Alan A. ;
Blue, Laura J. ;
Rogers, Joseph G. .
JOURNAL OF HEART AND LUNG TRANSPLANTATION, 2011, 30 (07) :838-840
[25]   Impact of anatomical position of the inflow cannula on stroke in patients with left ventricular assist devices [J].
Takada, Takuma ;
Nishinaka, Tomohiro ;
Ichihara, Yuki ;
Saito, Satoshi ;
Imamura, Yasutaka ;
Kikuchi, Noriko ;
Hattori, Hidetoshi ;
Suzuki, Atsushi ;
Ashihara, Kyomi ;
Shiga, Tsuyoshi ;
Nunoda, Shinichi ;
Hagiwara, Nobuhisa ;
Niinami, Hiroshi .
INTERNATIONAL JOURNAL OF ARTIFICIAL ORGANS, 2022, 45 (01) :27-34
[26]   In Vitro Evaluation of Inflow Cannula Fixation Techniques in Left Ventricular Assist Device Surgery [J].
Hanke, Jasmin S. ;
Krabatsch, Thomas ;
Rojas, Sebastian V. ;
Deniz, Ezin ;
Ismail, Issam ;
Martens, Andreas ;
Shrestha, Malakh ;
Haverich, Axel ;
Netuka, Ivan ;
Schmitto, Jan D. .
ARTIFICIAL ORGANS, 2017, 41 (03) :272-275
[27]   Right ventricular function and residual mitral regurgitation after left ventricular assist device implantation determines the incidence of right heart failure [J].
Tang, Paul C. ;
Haft, Jonathan W. ;
Romano, Matthew A. ;
Bitar, Abbas ;
Hasan, Reema ;
Palardy, Maryse ;
Wu, Xiaoting ;
Aaronson, Keith D. ;
Pagani, Francis D. .
JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 2020, 159 (03) :897-+
[28]   Impact of mitral valve intervention with left ventricular assist device implantation on postoperative outcomes and morphologic change [J].
Hata, Hiroki ;
Fujita, Tomoyuki ;
Ishibashi-Ueda, Hatsue ;
Kuroda, Kensuke ;
Seguchi, Osamu ;
Matsumoto, Yorihiko ;
Yanase, Masanobu ;
Sato, Takuma ;
Nakajima, Seiko ;
Fukushima, Norihide ;
Kobayashi, Junjiro .
JOURNAL OF ARTIFICIAL ORGANS, 2018, 21 (02) :164-171
[29]   Resolution of Mitral Regurgitation With Left Ventricular Assist Device Support [J].
Goodwin, Matthew ;
Nemeh, Hassan W. ;
Borgi, Jamil ;
Paone, Gaetano ;
Morgan, Jeffrey A. .
ANNALS OF THORACIC SURGERY, 2017, 104 (03) :811-819
[30]   Understanding the influence of left ventricular assist device inflow cannula alignment and the risk of intraventricular thrombosis [J].
Michael Neidlin ;
Sam Liao ;
Zhiyong Li ;
Benjamin Simpson ;
David M. Kaye ;
Ulrich Steinseifer ;
Shaun Gregory .
BioMedical Engineering OnLine, 20