A high-pressure hydrogen time projection chamber for the MuCap experiment

被引:3
|
作者
Egger, J. [1 ]
Fahrni, D. [1 ]
Hildebrandt, M. [1 ]
Hofer, A. [1 ]
Meier, L. [1 ]
Petitjean, C. [1 ]
Andreev, V. A. [2 ]
Banks, T. I. [3 ]
Clayton, S. M. [4 ]
Ganzha, V. A. [2 ]
Gray, F. E. [3 ,5 ,6 ]
Kammel, P. [4 ,6 ]
Kiburg, B. [4 ,6 ]
Kravtsov, P. A. [2 ]
Krivshich, A. G. [2 ]
Lauss, B. [1 ,3 ]
Maev, E. M. [2 ]
Maev, O. E. [2 ]
Petrov, G. [2 ]
Semenchuk, G. G. [2 ]
Vasilyev, A. A. [2 ]
Vorobyov, A. A. [2 ]
Vznuzdaev, M. E. [2 ]
Winter, P. [4 ,6 ]
机构
[1] Paul Scherrer Inst, CH-5232 Villigen, Switzerland
[2] Petersburg Nucl Phys Inst, Gatchina 188350, Russia
[3] Univ Calif Berkeley, Dept Phys, Berkeley, CA 94720 USA
[4] Univ Illinois, Dept Phys, Urbana, IL 61801 USA
[5] Regis Univ, Dept Phys & Computat Sci, Denver, CO 80221 USA
[6] Univ Washington, Dept Phys, Seattle, WA 98195 USA
基金
美国国家科学基金会;
关键词
ELASTIC-SCATTERING; WIRE CHAMBERS; MUON-CAPTURE; PRECISION; SYSTEM; GAS; PERFORMANCE; SIMULATION; DETECTORS;
D O I
10.1140/epja/i2014-14163-1
中图分类号
O57 [原子核物理学、高能物理学];
学科分类号
070202 ;
摘要
The MuCap experiment at the Paul Scherrer Institute performed a high-precision measurement of the rate of the basic electroweak process of nuclear muon capture by the proton, mu(-) + p -> n + v(mu). The experimental approach was based on the use of a time projection chamber (TPC) that operated in pure hydrogen gas at a pressure of 10 bar and functioned as an active muon stopping target. The TPC detected the tracks of individual muon arrivals in three dimensions, while the trajectories of outgoing decay (Michel) electrons were measured by two surrounding wire chambers and a plastic scintillation hodoscope. The muon and electron detectors together enabled a precise measurement of the mu p atom's lifetime, from which the nuclear muon capture rate was deduced. The TPC was also used to monitor the purity of the hydrogen gas by detecting the nuclear recoils that follow muon capture by elemental impurities. This paper describes the TPC design and performance in detail.
引用
收藏
页数:16
相关论文
共 50 条
  • [21] Molecular study of high-pressure hydrogen decompression in amorphous polyethylene
    Ding, Guozhen
    Tighe, Christopher J.
    Tam, Lik-ho
    Wu, Chao
    INTERNATIONAL JOURNAL OF HYDROGEN ENERGY, 2025, 114 : 267 - 278
  • [22] Effect of burst disk parameters on the release of high-pressure hydrogen
    Gong, Liang
    Duan, Qiangling
    Liu, Jialong
    Li, Mi
    Jin, Kaiqiang
    Sun, Jinhua
    FUEL, 2019, 235 : 485 - 494
  • [23] Estimation of turbulence characteristics from PIV in a high-pressure fan-stirred constant volume combustion chamber
    Xu, Shijie
    Huang, Sheng
    Huang, Ronghua
    Wei, Wenming
    Cheng, Xiaobei
    Ma, Yinjie
    Zhang, Yu
    APPLIED THERMAL ENGINEERING, 2017, 110 : 346 - 355
  • [24] Experimental study on impact coupling characteristics of high-pressure accumulator for unconstant-pressurized chamber rock drills
    Tian, Xiang
    Xi, Weihang
    Ma, Fei
    Zhang, Zihang
    Wang, Songyuan
    Geng, Xiaoguang
    ADVANCES IN MECHANICAL ENGINEERING, 2024, 16 (10)
  • [25] The laser system for the STAR time projection chamber
    Abele, J
    Berkovitz, J
    Boehm, J
    Brandin, A
    Gushin, E
    Harper, G
    Lebedev, A
    Love, WA
    Ridiger, A
    Strikhanov, M
    Weidenbach, J
    Wells, R
    Wolf, J
    Wirth, J
    Wieman, HH
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2003, 499 (2-3) : 692 - 702
  • [26] Simulation of the time-projection chamber with triple GEMs for the LAMPS at RAON
    Jhang, Genie
    Lee, Jung Woo
    Moon, Byul
    Hong, Byungsik
    Ahn, Jung Keun
    Lee, Jong-Won
    Lee, Kyong Sei
    Kim, Young Jin
    Lee, Hyo Sang
    JOURNAL OF THE KOREAN PHYSICAL SOCIETY, 2016, 68 (05) : 645 - 652
  • [27] Influence of pressure cycling on damage evolution in an unfilled EPDM exposed to high-pressure hydrogen
    Ono, Hiroaki
    Nait-Ali, Azdine
    Diallo, Ousseynou Kane
    Benoit, Guillaume
    Castagnet, Sylvie
    INTERNATIONAL JOURNAL OF FRACTURE, 2018, 210 (1-2) : 137 - 152
  • [28] A time projection chamber for high accuracy and precision fission cross-section measurements
    Heffner, M.
    Asner, D. M.
    Baker, R. G.
    Baker, J.
    Barrett, S.
    Brune, C.
    Bundgaard, J.
    Burgett, E.
    Carter, D.
    Cunningham, M.
    Deaven, J.
    Duke, D. L.
    Greife, U.
    Grimes, S.
    Hager, U.
    Hertel, N.
    Hill, T.
    Isenhower, D.
    Jewell, K.
    King, J.
    Klay, J. L.
    Kleinrath, V.
    Kornilov, N.
    Kudo, R.
    Laptev, A. B.
    Leonard, M.
    Loveland, W.
    Massey, T. N.
    McGrath, C.
    Meharchand, R.
    Montoya, L.
    Pickle, N.
    Qu, H.
    Riot, V.
    Ruz, J.
    Sangiorgio, S.
    Seilhan, B.
    Sharma, S.
    Snyder, L.
    Stave, S.
    Tatishvili, G.
    Thornton, R. T.
    Tovesson, F.
    Towell, D.
    Towell, R. S.
    Watson, S.
    Wendt, B.
    Wood, L.
    Yao, L.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 759 : 50 - 64
  • [29] High-pressure cell for in situ neutron studies of hydrogen storage materials
    Aslan, Neslihan
    Horstmann, Christian
    Metz, Oliver
    Kotlyar, Oleg
    Dornheim, Martin
    Pistidda, Claudio
    Busch, Sebastian
    Lohstroh, Wiebke
    Mueller, Martin
    Pranzas, Klaus
    JOURNAL OF NEUTRON RESEARCH, 2019, 21 (3-4) : 125 - 135
  • [30] Release models for leaks from high-pressure hydrogen storage systems
    Li, Xue-Fang
    Christopher, David M.
    Bi, Jing-Liang
    CHINESE SCIENCE BULLETIN, 2014, 59 (19): : 2302 - 2308