Complex wavelet based quality assessment for AS-OCT images with application to Angle Closure Glaucoma diagnosis

被引:13
|
作者
Niwas, Swamidoss Issac [1 ]
Jakhetiya, Vinit [1 ,2 ]
Lin, Weisi [1 ]
Kwoh, Chee Keong [1 ]
Sng, Chelvin C. [4 ]
Aquino, Maria Cecilia [3 ]
Victor, Koh [4 ]
Chew, Paul T. K. [4 ]
机构
[1] Nanyang Technol Univ, Sch Comp Engn, Singapore 639798, Singapore
[2] Hong Kong Univ Sci & Technol, Dept Elect & Comp Engn, Hong Kong, Hong Kong, Peoples R China
[3] Natl Univ Hlth Syst, Eye Surg Ctr, Singapore 119228, Singapore
[4] Natl Univ Singapore, Yong Loo Lin Sch Med, Dept Ophthalmol, Singapore 119228, Singapore
关键词
Optical coherence tomography; Angle closure glaucoma; Complex wavelets; Local binary pattern; Image quality assessment; Machine learning; LOCAL BINARY PATTERNS; FEATURE-SELECTION; CLASSIFICATION; INFORMATION;
D O I
10.1016/j.cmpb.2016.03.011
中图分类号
TP39 [计算机的应用];
学科分类号
081203 ; 0835 ;
摘要
Background and objectives: Angle closure disease in the eye can be detected using time-domain Anterior Segment Optical Coherence Tomography (AS-OCT). The Anterior Chamber (AC) characteristics can be quantified from AS-OCT image, which is dependent on the image quality at the image acquisition stage. To date, to the best of our knowledge there are no objective or automated subjective measurements to assess the quality of AS-OCT images. Methods: To address AS-OCT image quality assessment issue, we define a method for objective assessment of AS-OCT images using complex wavelet based local binary pattern features. These features are pooled using the Naive Bayes classifier to obtain the final quality parameter. To evaluate the proposed method, a subjective assessment has been performed by clinical AS-OCT experts, who graded the quality of AS-OCT images on a scale of good, fair, and poor. This was done based on the ability to identify the AC structures including the position of the scleral spur. Results: We compared the results of the proposed objective assessment with the subjective assessments. From this comparison, it is validated that the proposed objective assessment has the ability of differentiating the good and fair quality AS-OCT images for glaucoma diagnosis from the poor quality AS-OCT images. Conclusions: This proposed algorithm is an automated approach to evaluate the AS-OCT images with the intention for collecting of high quality data for further medical diagnosis. Our proposed quality index has the ability of automatic objective and quantitative assessment of AS-OCT image quality and this quality index is similar to glaucoma specialist. (C) 2016 Elsevier Ireland Ltd. All rights reserved.
引用
收藏
页码:13 / 21
页数:9
相关论文
共 46 条
  • [1] Multilevel CNN for Angle Closure Glaucoma Detection using AS-OCT Images
    Ferreira, Marcos Melo
    Esteve, Giovanna Pavani
    Braz Junior, Geraldo
    Sousa de Almeida, Joao Dallyson
    de Paiva, Anselmo Cardoso
    Veras, Rodrigo
    PROCEEDINGS OF THE 2020 INTERNATIONAL CONFERENCE ON SYSTEMS, SIGNALS AND IMAGE PROCESSING (IWSSIP), 27TH EDITION, 2020, : 105 - 110
  • [2] Hybrid Variation-Aware Network for Angle-Closure Assessment in AS-OCT
    Hao, Jinkui
    Li, Fei
    Hao, Huaying
    Fu, Huazhu
    Xu, Yanwu
    Higashita, Risa
    Zhang, Xiulan
    Liu, Jiang
    Zhao, Yitian
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2022, 41 (02) : 254 - 265
  • [3] Multiview Volume and Temporal Difference Network for Angle-Closure Glaucoma Screening from AS-OCT Videos
    Hao, Luoying
    Hu, Yan
    Higashita, Risa
    Yu, James J. Q.
    Zheng, Ce
    Liu, Jiang
    JOURNAL OF HEALTHCARE ENGINEERING, 2022, 2022
  • [4] Segmentation and Quantification for Angle-Closure Glaucoma Assessment in Anterior Segment OCT
    Fu, Huazhu
    Xu, Yanwu
    Lin, Stephen
    Zhang, Xiaoqin
    Wong, Damon Wing Kee
    Liu, Jiang
    Frangi, Alejandro F.
    Baskaran, Mani
    Aung, Tin
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2017, 36 (09) : 1930 - 1938
  • [5] Angle Closure Glaucoma Detection using Fractal Dimension Index on SS-OCT images
    Ni, Soe Ni
    Marziliano, Pina
    Wong, Hon-Tym
    2014 36TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY (EMBC), 2014, : 3885 - 3888
  • [6] Angle-closure assessment in anterior segment OCT images via deep learning
    Hao, Huaying
    Zhao, Yitian
    Yan, Qifeng
    Higashita, Risa
    Zhang, Jiong
    Zhao, Yifan
    Xu, Yanwu
    Li, Fei
    Zhang, Xiulan
    Liu, Jiang
    MEDICAL IMAGE ANALYSIS, 2021, 69
  • [7] Dynamic analysis of iris changes and a deep learning system for automated angle-closure classification based on AS-OCT videos
    Luoying Hao
    Yan Hu
    Yanwu Xu
    Huazhu Fu
    Hanpei Miao
    Ce Zheng
    Jiang Liu
    Eye and Vision, 9
  • [8] Dynamic analysis of iris changes and a deep learning system for automated angle-closure classification based on AS-OCT videos
    Hao, Luoying
    Hu, Yan
    Xu, Yanwu
    Fu, Huazhu
    Miao, Hanpei
    Zheng, Ce
    Liu, Jiang
    EYE AND VISION, 2022, 9 (01)
  • [9] Automated grading of anterior segment Swept Source OCT images: A validation study for assessment of angle closure
    Porporato, Natalia
    Mani, Baskaran
    Xu Yanwu
    Tun, Tin A.
    Trikha, Sameer
    Wong, Damon W. K.
    Aung, Tin
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2017, 58 (08)
  • [10] AUTOMATIC ANGLE-CLOSURE GLAUCOMA SCREENING BASED ON THE LOCALIZATION OF SCLERAL SPUR IN ANTERIOR SEGMENT OCT
    Li, Panming
    Geng, Le
    Zhu, Weifang
    Shi, Fei
    Chen, Xinjian
    2020 IEEE 17TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI 2020), 2020, : 1387 - 1390