Rigid endoscopic resection of deep-seated or intraventricular brain tumors

被引:15
作者
Akiyama, Yukinori [1 ]
Wanibuchi, Masahiko [1 ]
Mikami, Takeshi [1 ]
Horita, Yoshifumi [1 ]
Komatsu, Katsuya [1 ]
Suzuki, Kengo [1 ]
Otaki, Shunya [1 ]
Mikuni, Nobuhiro [1 ]
机构
[1] Sapporo Med Univ, Dept Neurosurg, Sch Med, Sapporo, Hokkaido 0608543, Japan
关键词
Rigid endoscopy; Deep-seated brain tumor; Intraventricular brain tumor; Two-handed endoscopic technique; SYSTEM; RETRACTOR; LESIONS; BIOPSY; STEREOTAXY; FRAMELESS; REMOVAL; BLOOD;
D O I
10.1179/1743132814Y.0000000439
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Rigid endoscopic resection using a thick sheath (ViewSite) may be a viable method for the resection or biopsy of selected deep-seated brain tumors, such as thalamic gliomas and malignant lymphomas. Neuroendoscopic biopsy is one technique used for the histological verification of suspected brain tumors. There are a number of advantages to using this technique. For example, under direct vision, it is possible to carefully observe the tumor surface and avoid vessels during tumor resections. It is also possible to collect enough specimens for a pathological diagnosis. Eighteen consecutive patients safely underwent rigid endoscopic resection or biopsy using a thick sheath (ViewSite). The two-handed endoscopic technique that utilized a mounted rigid endoscope proved very useful and safe, since it enabled easy stanching of hemorrhages. The aim of this study was to demonstrate how to use a thick sheath for deep-seated or intraventricular tumors. The rigid endoscopic approach with a thick sheath provides an alternative medial approach with improved visualization and a wider working space.
引用
收藏
页码:278 / 282
页数:5
相关论文
共 22 条
[1]   Intra-parenchymal tumor biopsy using neuroendoscopy with navigation [J].
Akai, T. ;
Shiraga, S. ;
Sasagawa, Y. ;
Okamoto, K. ;
Tachibana, O. ;
Iizuka, H. .
MINIMALLY INVASIVE NEUROSURGERY, 2008, 51 (02) :83-86
[2]  
[Anonymous], NEUROSURGERY
[3]  
Cohen-Gadol AA, 2013, WORLD NEUROSURG, V79, pe7, DOI DOI 10.10.1016/J.WNEU.2011.03.045
[4]   SELF-RETAINING RETRACTOR AND HANDREST SYSTEM FOR NEUROSURGERY [J].
GREENBERG, IM .
NEUROSURGERY, 1981, 8 (02) :205-208
[5]  
Greenfield JP, 2008, NEUROSURGERY, V63, P334, DOI [10.1227/01.NEU.0000334741.61745.72, 10.1227/01.neu.0000334741.61745.72]
[6]   RESULTS OF 200 INTRACRANIAL STEREOTAXIC BIOPSIES [J].
GRUNERT, P ;
UNGERSBOCK, K ;
BOHL, J ;
KITZ, K ;
HOPF, N .
NEUROSURGICAL REVIEW, 1994, 17 (01) :59-66
[7]  
Harris Anthony E, 2005, Neurosurgery, V56, P125
[8]  
Jackson RJ, 2001, NEURO-ONCOLOGY, V3, P193, DOI 10.1093/neuonc/3.3.193
[9]   Endoscopic removal of third ventricular tumors: ATechnical note [J].
Jho, HD ;
Alfieri, A .
MINIMALLY INVASIVE NEUROSURGERY, 2002, 45 (02) :114-119
[10]   Completely endoscopic resection of intraparenchymal brain tumors [J].
Kassam, Amin B. ;
Engh, Johnathan A. ;
Mintz, Arlan H. ;
Prevedello, Daniel M. .
JOURNAL OF NEUROSURGERY, 2009, 110 (01) :116-123