Working fluid study for loop heat pipes

被引:14
作者
Singh, Randeep [1 ]
Nguyen, Tien [2 ]
Mochizuki, Masataka [2 ]
Akbarzadeh, Aliakbar [3 ]
机构
[1] Fujikura Automot Europe GmbH, Manchinger Str 114, D-85053 Ingolstadt, Germany
[2] Fujikura Ltd, Koto Ku, 1-5-1 Kiba, Tokyo 1358512, Japan
[3] RMIT Univ, Sch Engn, Melbourne, Vic 3000, Australia
关键词
Loop heat pipe; Capillary evaporator; Liquid charge ratio; Working fluid; Thermal management; EVAPORATOR;
D O I
10.1016/j.tsep.2022.101451
中图分类号
O414.1 [热力学];
学科分类号
摘要
Loop heat pipes (LHPs) provide unique applications for high heat flux and long distance heat transfer. Working fluid aspects, including liquid charging ratio, type and fluid dynamics, in loop heat pipe is quite different as compared to conventional heat pipe. This paper will particularly endeavor to explain these differences, and provide optimal design conditions achieved via experimental study. Design considerations and operational aspects of LHP with respect to working fluid is evaluation and discussed in detail. Important thermal-fluid properties with respect to pressure-temperature relation and merit number are outlined for various heat transfer fluids to choose best option for given conditions. LHP with capillary evaporator, 25 mm diameter and 155 mm long, and heat transfer length -250 mm was designed to study and optimize different working fluid aspects including optimum working fluid range for different orientations, effect of fluid type on performance and operational dynamics of loop related to fluid (start-up, oscillations, hysteresis and buoyancy effects). Loop utilized copper containment, nickel wick and mainly water as working fluid. As an outcomes of this investigation, it has been concluded that liquid ratio in range of 40 to 60 % of loop volume provide optimum charge, for different orientations, with 50 % charge showing best thermal performance. In summary, considered working fluid type and optimized overall liquid amount, calculated by giving due consideration to volumes of different loop components, can help to get best performance from the loop systems.
引用
收藏
页数:16
相关论文
共 33 条
[1]  
Anand A., 2017, P 24 NAT 2 INT ISHMT
[2]   Steady-state modeling and analysis of a loop heat pipe under gravity-assisted operation [J].
Bai, Lizhan ;
Guo, Jinghui ;
Lin, Guiping ;
He, Jiang ;
Wen, Dongsheng .
APPLIED THERMAL ENGINEERING, 2015, 83 :88-97
[3]   Experimental study on the thermal performance of a small-scale loop heat pipe with polypropylene wick [J].
Boo, JH ;
Chung, WB .
JOURNAL OF MECHANICAL SCIENCE AND TECHNOLOGY, 2005, 19 (04) :1052-1061
[4]   Thermal performance of a loop heat pipe having polypropylene wick in a flat evaporator [J].
Boo, Joon Hong ;
Chung, Won Bok .
HT2005: Proceedings of the ASME Summer Heat Transfer Conference 2005, Vol 4, 2005, :473-478
[5]   Effect of liquid filtration in a wick on thermal processes in a flat disk-shaped evaporator of a loop heat pipe [J].
Chernysheva, M. A. ;
Maydanik, Yu. F. .
INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 106 :222-231
[6]  
Dunbar N., 1998, P CPL 98 WORKSH EI S
[7]  
Dunn P., 1994, Heat Pipes, V4th
[8]  
Faghri Amir., 1995, HEAT PIPE SCI TECHNO
[9]   Derivation and Validation of a Figure of Merit for Loop Heat Pipes With Medium Temperature Working Fluids [J].
Joung, Wukchul ;
Lee, Jinho ;
Lee, Sanghyun ;
Lee, Joohyun .
JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2016, 138 (05)
[10]   Thermal operational characteristics of a small-loop heat pipe [J].
Kaya, T ;
Ku, JT .
JOURNAL OF THERMOPHYSICS AND HEAT TRANSFER, 2003, 17 (04) :464-470